• Title/Summary/Keyword: 관절 고정술

Search Result 358, Processing Time 0.024 seconds

Arthroscopic Ankle Arthrodesis Using Three Cannulated Screws (3개의 유관 나사를 이용한 관절경적 족근 관절 고정술)

  • Kim, Kyung-Tae;Lee, Song;Ko, Dong-Oh;Yang, Seung-Jin;Chun, Tae-Hwan;Yang, Jong-Hwa
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.249-253
    • /
    • 2009
  • Purpose: We evaluated the clinical and radiographic results of arthroscopic ankle arthrodesis using 3 cannulated screws for the treatment of arthritis of ankle. Materials and Methods: From May 2006 to February 2009, 17 cases of arthritis of ankle were treated by ankle arthrodesis using 3 cannulated screws under arthroscopy. There were 8 male and 7 female and the average age was 62.2 years. We evaluated them clinically using AOFAS ankle-hindfoot functional scale, VAS pain score and patient’s satisfaction. For the radiographic evaluation, we checked them by simple AP, lateral and mortise view. The average follow-up period was 24.2 months. Results: The ankle-hindfoot functional scale was improved from an average of 47.4 points preoperatively to an average of 82.5 points at the last follow-up. The visual analogue scale pain score was decreased from an average of 8.6 to 2.4. Patient's satisfaction had favorable results with excellent in 7 cases(41.2%), good in 8 cases(47.0%), fair in 1 case(5.9%) and poor in1 case(5.9%). All ankles were successfully fused and the mean period of fusion was 9.1 weeks. Conclusion: Arthroscopic ankle arthrodesis using 3 cannulated screws was good modality of ankle arthrodesis with good clinical results and high union rate in the case of advanced ankle arthritis.

  • PDF

Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix - (자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 -)

  • Yoo, Jae-Doo;Roh, Kwon-Jae;Shin, Sang-Jin;Yoon, Jong-Suk;Yeo, Sung-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • Purpose: To compare the stability and clinical result after anterior cruciate ligament reconstructed knee after graft fixation using Intrafix in tibial tunnel with or without additional tibial post fixation. Materials and Methods: We analyzed 37 cases which were treated with four-strand hamstring tendon autograft during the period from May 2002 to January 2003. The grafts were fixed with Rigidfix system (Mitek Product, Johnson and Johnson, USA) in femur tunnel and Intrafix system (Mitek Product, Johnson and Johnson, USA) in tibial tunnel. After tibial fixation, additional tibial post fixation was done, which was determined by the serial case number prospectively. Patients were followed for average of fourteen months(range, thirteen to twenty-five months) At the time of final follow-up, patients were evaluated in terms of Lachman test, pivot shift test, Lysholm scores, IKDC (International Knee Documentation Committee) assessment, side-to-side KT-1000 maximum-manual arthrometer differences. Results: At last follow-up, Lysholm score was average 93.1(range: 65 to 98), IKDC assessment revealed that 26 cases had score of A, 10 cases had score of B and 1 case had score of C. The average maximum-manual KT-1000 arthrometer side ?to-side difference was 2.5 mm$(0{\sim}6mm)$. There was one case in which the Lachman test was graded as 2+ and four cases in which the Lachman test was graded as 1+ and the remaining thirty-two cases were normal by Lachman test. One case had a 2+ pivot-shift, and 2 cases had a 11 pivot-shift. The remaining 34 knees were normal on pivot -shift testing. The average maximum-manual KT-1000 arthrometer side-to-side difference was average 2.8 mm$(0{\sim}6mm)$ in Intrafix only group and average 2.2 mm$(0{\sim}4mm)$ in additional fixation group (P>0.05). Conclusion: Without additional tibial fixation, the stability of the anterior cruciate reconstructed knee with hamstring graft which was fixed with Intrafix was restored.

  • PDF

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF

Mid-Term Results of Fixed Bearing Unicompartmental Knee Arthroplasty: Minimum 5-Year Follow-Up (고정형 슬관절 단일 구획 치환술의 중기 추시 결과: 최소 5년 추시)

  • Oh, Jeong Han;Joo, Il-Han;Kong, Dong-Yi;Choi, Choong-Hyeok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.498-504
    • /
    • 2018
  • Purpose: To evaluate the clinical and radiological outcomes, and the complications of unicompartmental knee arthroplasty (UKA) using a fixed bearing prosthesis after 5-year follow-up. Materials and Methods: Twenty-six knees (25 patients) that underwent fixed bearing UKA between May 2003 and August 2011 were included. The subjects were 3 males (3 knees) and 22 females (23 knees), and the average age was 63.5 years. The preoperative diagnosis was osteoarthritis (23 knees) and osteonecrosis (3 knees). The mean follow-up duration was 67 months (from 60 to 149 months). The clinical evaluation included pre- and postoperative American knee society knee and function score, and range of motion. The radiology evaluation included standing antero-posterior, lateral view, and fluoroscopic film to analyze the postoperative alignment and osteolysis. Results: The mean American Knee Society knee score and function score were improved from 42.0 and 57.5 to 87.9 and 85.0, respectively (p<0.001). The mean preoperative and postoperative range of motion was $132.9^{\circ}$ and $132.5^{\circ}$, respectively. The mean femorotibial angle were varus $0.5^{\circ}$ preoperatively and valgus $2.2^{\circ}$ postoperatively. A radiolucent line was observed in 2 knees; one knee had a stable implant, while in the other knee, patellofemoral arthritis was identified during UKA. Diffuse pain of the knee joint with tenderness of the medial joint line was identified at the follow-up, so conversion to total knee arthroplasty was recommended. No other complications, such as osteolysis, infections, postoperative stiffness, and dislocation, were encountered. Conclusion: The midterm results of fixed bearing UKA were clinically and radiologically satisfactory.

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF

Arthroscopic Distal Clavicle Resection for Chronic Stage 2 Acromioclavicular Dislocation - Preliminary Report of 6 Cases Study - (관절경하 원위 쇄골 절제술을 이용한 만성 제 2형 견봉쇄골 손상의 치료 - 6례에 대한 예비 연구 -)

  • Yoo Yeun-Sik;Yoon Young-Gon;Nam Il-Hyun;Moon Gi-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.171-176
    • /
    • 2002
  • Purpose : To evaluate effectiveness of arthroscopic distal clavicle resection for chronic stage 2 acromioclavicular dislocation. Material: 6 patients who had failed to respond to physical therapy were evaluate more than 6 months prospectively, which were treated with arthroscopic distal clavicular resection from february 1998 to January 2001. Result : The median preoperative Constant score changed from 32 of 100 to 37 of 100 at 3 to 6 weeks, to 49 of 100 at 3 months and to 69 of 100 at 6months. Improvement was achived at mean follow up more than 6 months after surgery. Overal $83\%$ of patient were satisfied with this procedure. but the remained case was unsatisfied because symptom was not improved more than 6 months Conclusion : Arthroscopic distal clavicle resection is useful method to treatment for chronic stage 2 acromioclavicular dislocation.

  • PDF