• Title/Summary/Keyword: 관성측정 장치

Search Result 145, Processing Time 0.023 seconds

Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit (관성측정장치를 이용한 경추관절 가동범위 측정의 검사 내 반복성 및 검사-재검사 신뢰도 연구)

  • Kim, Hyun Ho;Kim, Kyung Wook;Park, Ji Min;Kim, Eun Seok;Lee, Min Jun;Kang, Jung Won;Lee, Sang Hoon;Park, Young Bae
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.25-33
    • /
    • 2013
  • Objectives : To assess the test-retest reliability and the intratest repeatability in measuring the cervical range of motion of healthy subjects with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the cervical spine musculoskeletal. Methods : 12 healthy people who were evaluated as no- or mild-disability with neck disability index were participated. Their cervical motion were measured with IMU twice in consecutive two days for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Cervical range of motion data were acquired and statistically processed: left rotation($61.64^{\circ}$), right rotation($65.12^{\circ}$), extension($61.98^{\circ}$), flexion($52.81^{\circ}$), left bending($39.31^{\circ}$), right bending($41.08^{\circ}$). ICCs were 0.77~0.98(intratest repeatability) and 0.74~0.93 (test-retest reliability) in the primary motion. In the coupling motion, intratest repeatability ICCs were 0.93~ 0.99(transverse primary plane), 0.88~0.97(saggital primay plane), and 0.77~0.93(coronal primary plane). Test-retest reliability of coupling motion were 0.90~0.97(transverse primary plane), 0.00~0.72(saggital primary plane), and 0.04~0.76(coronal primary plane). Conclusions : Several types of range-of-motion devices are now on use in many fields including medicine, but the practicality of the devices in clinical use is questionable for the convenient and economical aspects. In this study, we presented the reliability of cervical range of motion test with the developed wireless MEMS-IMU system and discussed its potential utility in clinical use.

Fabrication of Three-Dimensional Scanning System for Inspection of Mineshaft Using Multichannel Lidar (다중채널 Lidar를 이용한 수직갱도 조사용 3차원 형상화 장비 구현)

  • Soolo, Kim;Jong-Sung, Choi;Ho-Goon, Yoon;Sang-Wook, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.451-463
    • /
    • 2022
  • Whenever a mineshaft accidentally collapses, speedy risk assessment is both required and crucial. But onsite safety diagnosis by humans is reportedly difficult considering the additional risk of collapse of the unstable mineshaft. Generally, drones equipped with high-speed lidar sensors can be used for such inspection. However, the drone technology is restrictively applicable at very shallow depth, failing in mineshafts with depths of hundreds of meters because of the limit of wireless communication and turbulence inside the mineshaft. In previous study, a three-dimensional (3D) scanning system with a single channel lidar was fabricated and operated using towed cable in a mineshaft to a depth of 200 m. The rotation and pendulum movement errors of the measuring unit were compensated for by applying the data of inertial measuring unit and comparing the similarity between the scan data of the adjacent depths (Kim et al., 2020). However, the errors grew with scan depth. In this paper, a multi-channel lidar sensor to obtain a continuous cross-sectional image of the mineshaft from a winch system pulled from bottom upward. In this new approach, within overlapped region viewed by the multi-channel lidar, rotation error was compensated for by comparing the similarity between the scan data at the same depth. The fabricated system was applied to scan 0-165 m depth of the mineshaft with 180 m depth. The reconstructed image was depicted in a 3D graph for interpretation.

Human-Powered Generator designed for Sustainable Driving (고출력 지속이 가능한 인체 구동 방식의 자가 발전기 개발)

  • Lim, Yoon-Ho;Yang, Yoonseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.135-142
    • /
    • 2015
  • Human-powered self-generating devices have been attractive with its operation characteristic independent from outer environment such as weather condition and wind speed. However, conventional self-generators have low electric power output due to their weakly-coupled electromagnetic structure. More importantly, rotary crank motion which is usually adopted by conventional self-generator to generate electricity requires specific skeletal muscles to maintain large torque circular motion and consequently, causes fatigue on those muscles before it can generate enough amount of electricity for any practical application. Without improvement in electric power output and usability, the human-powered self-generator could not be used in everyday life. This study aims to develop a human-powered self-generator which realized a strong electromagnetic coupling in a closed-loop tubular structure (hula-hoop shape) for easy and steady long-term driving as well as larger electric output. The performance and usability of the developed human-powered generator is verified through experimental comparison with a commercial one. Additionally, human workload which is a key element of a human-powered generator but not often considered elsewhere, is estimated based on metabolic energy expenditure measured respiratory gas analyzer. Further study will focus on output and portability enhancement, which can contribute to the continuous power supply of mobile equipments.

GPS/INS Integration and Preliminary Test of GPS/MEMS IMU for Real-time Aerial Monitoring System (실시간 공중 자료획득 시스템을 위한 GPS/MEMS IMU 센서 검증 및 GPS/INS 통합 알고리즘)

  • Lee, Won-Jin;Kwon, Jay-Hyoun;Lee, Jong-Ki;Han, Joong-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.225-234
    • /
    • 2009
  • Real-time Aerial Monitoring System (RAMS) is to perform the rapid mapping in an emergency situation so that the geoinformation such as orthophoto and/or Digital Elevation Model is constructed in near real time. In this system, the GPS/INS plays an very important role in providing the position as well as the attitude information. Therefore, in this study, the performance of an IMU sensor which is supposed to be installed on board the RAMS is evaluated. And the integration algorithm of GPS/INS are tested with simulated dataset to find out which is more appropriate in real time mapping. According to the static and kinematic results, the sensor shows the position error of 3$\sim$4m and 2$\sim$3m, respectively. Also, it was verified that the sensor performs better on the attitude when the magnetic field sensor are used in the Aerospace mode. In the comparison of EKF and UKF, the overall performances shows not much differences in straight as well as in curved trajectory. However, the calculation time in EKF was appeared about 25 times faster than that of UKF, thus EKF seems to be the better selection in RAMS.

Synthesis of Pt-Bi/Carbon Electrodes by Reduction Method for Direct Methanol Fuel Cell (환원법에 의한 직접 메탄올 연료전지(DMFC)용 Pt-Bi/Carbon 전극제조)

  • Kim, Kwan Sung;Kim, Min Kyung;Noh, Dong Kyun;Tak, Yongsug;Baeck, Sung-Hyeon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.479-485
    • /
    • 2011
  • Pt-Bi/C catalysts supported on carbon black with various Pt/Bi ratios were synthesized by a reduction method. Chloroplatinic acid hydrate ($H_2PtCl_6{\cdot}xH_2O$) and bismuth (III) nitrate pentahydrate ($Bi(NO_3)_3{\cdot}5H_2O$) were used as precursors for Pt and Bi, respectively. Before loading metal on carbon, heat treatment and pretreatment of carbon black in an acidic solution was conducted to enhance the degree of dispersion. The physical property of the synthesized catalysts was investigated by X-ray diffraction and X-ray photoelectron spectroscopy. The XRD pattern of untreated Pt-Bi/C catalyst showed BiPt and $Bi_2Pt$ peaks in addition to Pt peaks. These results imply that Bi atoms were incorporated into the Pt crystal lattice by Pt-Bi alloy formation. The catalytic activity for methanol oxidation was measured using cyclic voltammetry in a mixture of 0.5 M $H_2SO_4$ and 0.5 M $CH_3OH$ aqueous solution. The addition of proper amount of Bi was found to significantly improve catalytic activity for methanol oxidation. The catalytic activity for methanol oxidation was closely related to the stability between electrode and electrolyte. In order to investigate the stability of catalysts, chronoamperometry analysis was carried out in the same solution at 0.6 V.