• Title/Summary/Keyword: 관망해석

Search Result 236, Processing Time 0.024 seconds

determination of Optimum Pipe diameter Using Multi-Stage Iterative Method in Water Distribution system (다단계 반복기법을 이용한 관로시스템의 최적관경 결정)

  • Han, Geon-Yeon;Park, Jae-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.3
    • /
    • pp.327-335
    • /
    • 1998
  • The distribution network is an essential part of all water supply systems. The cost of this portion of any sizable water supply system may amount to most of the entire cost of the project. This study tried to reduce the cost of the distribution system through optimization in system design. To determine pipe diameter considered in water distribution system design, a iterative procedure linked the flow analysis model and optimization model was used. Linear theory was introduced to analyze flowrate and revised-simplex method based on linear programming is used to optimize pipe diameter. This model was applied to wter distribution system with 22 and 35 pipes, and rapidly determine optimized commercial pipe diameters. Keywords : water distribution system, revised simplex method, optimum pipe diameters.

  • PDF

Determination Methods of Pressure Monitoring Location in Water Distribution System (상수관망에서 수압모니터링지점 선정방법)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1103-1113
    • /
    • 2013
  • In this study, determination methods of the pressure monitoring location in water distribution system were introduced and applied to sample pipe network. The best determination method of the pressure monitoring location was suggested and applied to the real city pipe network. Three kinds of determination methods of pressure monitoring locations are categorized such as the sensitivity analysis according to changing roughness coefficient, pressure contribution analysis, and sensitivity analysis according to changing demand. Further-more, pressure contribution analysis and sensitivity analysis from the results of unsteady analysis were conducted and compared each other. From the results, the most accurate and simplest method was selected in this study. Therefore, the best method can be applied for the pressure management or leakage detection as a determination method of pressure monitoring location in water distribution system.

Realization of water distribution system digital twin model using parameter calibration model (상수도관망 디지털트윈 구현을 위한 해석 프로그램 매개변수 검보정 모형 개발)

  • Lee, Jaeyeon;Park, Jaehong;Lee, Seungyub
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.182-182
    • /
    • 2022
  • 4차산업 기술이 상수도 관망 분야에도 활발히 도입되며 스마트워터 구축에 기술적인 기반이 마련되고 있다. 이중 디지털트윈의 경우 컴퓨터에 현실 속 사물의 쌍둥이를 만들고, 현실에서 발생할 수 있는 상황을 컴퓨터로 시뮬레이션함으로써 결과를 미리 예측하는 기술로 정의된다. 즉, 디지털트윈의 핵심기술은 시각화와 시뮬레이션 모형의 연계로 실시간 상황 표출뿐만 아니라 시뮬레이션 모형 입력값의 미래 변화를 추정하여 해당 사물의 상태를 예측하는 것이라고 할 수 있다. 상수도 관망의 경우도 디지털트윈 모형 구축 시 정교한 시뮬레이션 모형과 연계를 통해 관측 데이터의 표출과 함께 미관측 지점의 데이터를 추정 및 표출하는 것이 중요하다. 본 연구에서는 디지털트윈 모형 구축에 가장 필수적이라고 할 수 있는 상수도 관망의 해석 프로그램 매개변수 검보정 모형을 소개한다. 대표적인 상수도 관망해석 프로그램인 EPANET2.2의경우 입력값으로 주로 수요량과 관로의 조도계수를 요구하며, 본 연구에서는 수요량은 알고 있는 것으로 가정하고 관로의 조도계수만 Markov-Chain Monte Carlo (MCMC)를 사용하여 검보정한다. 해당 모형은 (1) 실시간 조도계수 추정이 가능하면, (2) 동시에 누수 탐지가 가능하고, (3) 관로의 기능적 노후를 정의하여 향후 디지털트윈 모형 구현 시 관로 노후를 표출할 수 있는 기반을 구축한다. 우선 실시간 조도계수 추정은 데이터베이스와 연동하여 진행하며, MCMC 모형을 활용한 관로 별 조도계수의 분포에 따라 정상범위 내 변동이 발생하는지 여부를 판단한다. 이때 정상범위를 벗어난 변동이 발생하는 경우 잠재적 누수가 존재하는 것으로 가정하며, 콜모고로프-스미르노프(KS) 테스트를 통해 이를 판단한다. 기능적 노후는 관로의 통수능과 연관이 있으며, 추정한 조도계수에 따른 관로의 통수능을 산정하여 결과를 표출한다. 본 연구에서 제안한 모형은 향후 상수도 관망 디지털트윈 구현에 핵심 요소기술로 활용할 수 있을 것으로 기대한다.

  • PDF

Runoff and Unsteady Pipe Flow Computation (유출과 부정류 관수로 흐름 계산에 관한 연구)

  • Jeon, Byeong-Ho;Lee, Jae-Cheol;Gwon, Yeong-Ha
    • Water for future
    • /
    • v.23 no.2
    • /
    • pp.251-263
    • /
    • 1990
  • For surcharge flow in a sewer, the slot technique simulates surcharge flow as open - channel flow using a hypothetical narrow open piezometric slot at the sewer crown. The flow in a sewer is described mathematically using the unsteady open - channel Saint-Venant equations. In this study, the computer simulation model(USS-slot) using slot techniques is develeped to simulate the inlet hydrographs to manholes and the flow under pressure as well as free - surface flow in tree - type sewer networks of circular conduits. The inlet hydrographs are simulated by using the rational method or the ILSD progrm. The Saint-Venant equations for unsteady open - channel flow in seweres are solved by using a four - point implicit difference scheme. The flow equations of the sewers and the junction flow equations are solved simulaneously using a sparse matrix solution technique.

  • PDF

Parameter Optimization Analysis in Urban Flood Simulation by Applying 1D-2D Coupled Hydraulic Model (도시침수 최적화 모의를 위한 1D-2D 모형의 연계해석)

  • Kim, Beom Jin;Ha, Chang Yong;Kim, Byung-hyun;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.48-48
    • /
    • 2017
  • 도시지역에서는 이상강우, 돌발홍수와 더불어 급속한 도시화에 따라 침수 발생의 위험성이 증가하고 있다. 지자체에서는 빗물펌프장, 지하저류조 등을 이용하여 적극적으로 침수대책을 강구하고 있지만, 저지대 침수피해는 계속적으로 발생하고 있다. 2013년 7월 서울 경기북부 강원영서에 발생한 집중호우로 1명이 사망하고 피해액은 94,036백만원이 발생하였다. 춘천시 효자동 저지대지역의 주택침수는 인근 하천의 수위가 높아져 내수배제 및 하수도 처리 능력이 부족하여 침수가 발생하였다. 2014년 8월 경남지역에 발생한 집중호우로 2명 사망하였고, 피해액은 134,158백만원에 이르렀으며, 도시화 토지피복변화로 인한 홍수량이 증가하여 피해가 가중되었다. 이에 따라 도시 내 정확한 도시유출 및 침수해석을 통하여 과거 침수양상을 재현하고 앞으로 발생할 수 있는 침수피해를 방지할 수 있도록 침수 예 경보 시스템을 개발하여 도시침수에 대비하고 도시주민들의 인명과 재산피해를 경감하는데 그 목적이 있다. 이를 위해 도시지역의 관망해석에 적합한 모형을 선택하여야 하며, 그 모형의 매개변수를 결정하여야 한다. 도시유출해석 및 관망해석을 위하여 SWMM 모형을 선정해서 유역분할조건, 매개변수에 대한 최적 검정과정을 제시하여, 1D-2D 연계모형을 통해서 침수지역예측의 정확도를 증대시키고자 한다. 본 연구에서는 서울시 강남역 주변 일대의 5개 배수분구을 대상으로 도시유출해석을 위한 최적화 모의를 위하여 1D-2D모형의 연계해석하였다. 실제 강우사상을 적용하여 매개변수와 소유역 개수를 달리하여 자동최적화기법인 PEST를 이용하여 최적인자를 도출하여, 실제 배수맨홀의 수위관측 자료를 이용하여 비교 보정을 하였다. 도시유출해석뿐만 아니라 내수침수시의 최적인자 도출을 위해 2차원 범람해석을 통하여 NDMS 자료를 이용하여 비교 보정을 한 뒤 다른 강우사상을 이용하여 검증을 하여 도시침수 해석의 정확도를 개선을 위한 최적인자들을 검토하였다.

  • PDF

Optimization of Booster Disinfection Scheduling in Water Distribution Systems using Artificial Neural Networks (인공신경망을 이용한 상수관망 염소 재투입 스케줄링 최적화)

  • Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.18-18
    • /
    • 2018
  • 상수관망 시스템(Water Distribution System, WDS)은 이용자에게 양질의 상수도를 공급하기 위해 구축된 사회기반시설물로써, 정수된 물이 사용처에 도달하기까지 송수과정에서 발생 가능한 수질저하를 고려해야 한다. 일반적으로 정수장에서 염소처리를 한 후, 도달시간을 고려한 시스템 내 잔류 염소농도를 유지함으로써 수질저하를 예방한다. 여기서 상수도 내 잔류 염소농도는 미생물 번식 및 관내 부식물 등 다양한 생물 화학적 오염을 효과적으로 예방하는 반면, 과다할 경우 이용자의 음용성을 저해할 수 있어 시스템 전반에 걸쳐 염소농도의 적절한 관리가 요구된다. 특히, 상수관망에서는 공급경로 및 공급량에 따라 각 수요처의 도달 염소농도가 다르게 분포할 수 있으므로, 시설운영자는 균등하고 적절한 염소농도를 유지하기 위해 추가적인 염소 재투입시설을 설치하여 함께 관리하고 있다. 이 때, 염소투입 시설의 운영계획은 EPANET과 같은 상수관망 해석모형의 수질모의를 바탕으로 수립된다. 그러나 일반적으로 수질모의는 수리해석과는 달리 긴 시간이 소요되는 단점이 존재한다. 본 연구에서는 이러한 단점을 개선하기 위해, 특정 네트워크의 수질모의 결과를 학습시킨 인공신경망(ANN) 모형을 구축하고 이를 이용하여 상수관망 수질모의 계산시간을 단축하고자 하였다. 여기서 ANN모형의 학습은 EPANET을 통해 미리 선정된 다양한 염소 투입지점의 염소 투입농도와 용수 공급량 자료, 그리고 주요 관측지점에서 측정된 염소농도자료를 이용하였다. 학습된 ANN모형을 EPANET 수질모의 결과와 비교 및 검증을 실시한 결과, 사전에 소요된 학습시간을 제외하면 수질모의 소요시간 측면에서 큰 개선효과를 보였으며, 대표지점에서의 수질모의 결과가 유사하였다. 추가적으로, 본 연구에서는 학습된 ANN모형과 최적화 알고리즘인 GA(Genitic Algorithm)를 연계하여 상수관망에서의 염소 재투입 스케줄링을 최적화하는 프로그램을 개발함으로써, 안전하고 경제적인 상수관망의 수질운영에 기여하고자 하였다.

  • PDF