• Title/Summary/Keyword: 관로공사

Search Result 89, Processing Time 0.036 seconds

A Case Study of the Underwater Blasting Using Emulsion Explosives (에멀젼폭약을 사용한 수중발파 사례)

  • An, Bong-Do;Lee, Ik-Joo;Heo, The-Moon
    • Explosives and Blasting
    • /
    • v.25 no.2
    • /
    • pp.71-78
    • /
    • 2007
  • In many cases of underwater blasting in South Korea, the special blasting is mainly used for deepening harbor, installing gas pipes, or well blasting to build a bridge. The procedure of well blasting is almost same with shaft blasting, but the difference is that water is filled in before blasting. In case of deepening blasting under water, the first step like drilling, arranging explosives, and wire connection is done on a barge, then the next step such as charging and tamping is accomplished under water by expert divers. Therefore, underwater blasting needs precise and exact plan before blasting. In this paper, authors would like to introduce a case of underwater blasting for deepening the Busan new port with emulsion explosives and non-electric detonators in order to get some of 8,500TEU out sized container vessels entered into the port and to make safe. Considering environment and vibration, the blasting was controlled to minimized the damage to the lighthouse nearby. It will be great help to many other blasting sites where emulsion explosives and non-electric detonators are used for underwater blasting through this case.

A Study on Maximum Sidewall Pressure for Underground Transmission Cables (지중송전케이블 허용측압에 관한 연구 및 기술정립)

  • Kim, Du-Jin;Lee, Ji-Yeol;Suk, Kwang-Hyun;Kim, Jae-Seung;Kim, Tai-Young;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.553-554
    • /
    • 2011
  • 도심지간 대용량 전력수송을 담당하는 지중송전케이블의 설비 신뢰성 향상과 공사원가 절감을 위해 적정 포설길이의 결정과 접속함의 최적 배치가 중요하며, 이러한 시스템 설계에 있어서 허용 포설장력과 측압은 여러 중요 요소 중 하나가 된다. 특히, 허용측압 계산과정에서 적용중인 최대 측압값에 대한 실증적 검증과 건정성 확인시험을 통해 케이블 특성에 가장 적정한 값을 도출하고, 실 계통에 적용함으로서 최적 시스템 설계가 구현될 것이다. 따라서 본 연구에서는 지중송전케이블을 관로에 포설시 곡률부에서 발생하는 측압을 여러 case별로 모의할 수 있도록 실증설비를 구축하였고, 실제 작용되는 측면하중을 로드셀을 이용하여 측정하였다. 본 연구결과로 안전율을 고려한 최적의 허용측압이 결정되었으며, 이러한 허용측압의 확대를 통해 장경간 케이블 포설의 이론 정립이 가능하게 되었다.

  • PDF

Evaluation of Urban Flood Area Considering by Condition Rainfall Analysis (강우 조건별 영향을 고려한 도시지역의 침수범위 평가)

  • Keum, Ho Jun;Lee, Kyeong Wook;Kim, Byung Hyun;Kim, Hyeon Il;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.49-49
    • /
    • 2017
  • 최근 극한 홍수의 발생에 따른 내수배제 불량으로 인한 도시지역의 침수로 매년 많은 인명과 재산상의 손실이 크게 증가하고 있으며, 홍수피해 저감 및 복구대책으로 많은 국비가 지원되고 있으나 아직까지 예방보다는 복구비에 치중하고 있는 실정이다. 이에 본 연구에서는 도시지역에 시간 당 강우의 영향력에 대한 평가를 실시하여 상습적으로 일어나는 내수재해를 방지하고 자한다. 이를 위하여 서울시 저지대를 기준으로 상습침수 배수구역을 선택하여 1차원 SWMM모형을 구축하였다. 이때, 가장 중요한 인자 중 하나인 강우의 시간분포는 도시별 유역 규모 및 유출특성, 강우강도 특성 등에 따라 상이한 결과를 보일 여지가 다분하여 실제 침수를 일으킨 강우와 유사한 분포를 찾기 매우 어려운 실정이며, 이를 반영하기 위하여 Huff분포 모든 분위를 사용하여 SWMM 도시침수 해석을 실시하였다. 실시한 결과 맨홀의 월류량을 2차원 해석 입력자료로 사용하였으며, 2차원 해석 결과를 분위별 침수범위를 GIS를 이용하여 중첩시켜 상습 침수구역을 제시하였다. 본 연구 결과를 바탕으로 강우강도의 조건에 따라서 관로를 통하여 월류되는 시작 지점 및 그 지점을 통하여 맨홀에서의 월류량을 대략적 알 수 있었다. 또한, 능동적이며 준 실시간적인 대피지도와 우회도로설정 의사결정에 도움이 될 것으로 판단된다.

  • PDF

Determination of Optimal Valve Location in Water Distribution Networks (단수피해 최소화를 위한 상수관망 내 최적 밸브위치 선정)

  • Lim, Gab Yul;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.108-108
    • /
    • 2018
  • 상수관의 노후화 혹은 공사 중 작업자의 실수, 또는 자연재해 등에 의해 상수관망 내 파손 관이 발생할 경우 파손된 관의 보수 및 교체 작업을 위해서는 파손 관과 인접한 밸브를 차폐하게 된다. 이로 인하여 관망의 일부 지역에 물 공급이 차단되는 단수구역이 발생하게 되며, 단수구역은 밸브를 닫음으로 인해 파손 관과 함께 격리되는 직접고립지역(segment)과 직접고립지역을 차폐함으로써 의도치 않게 수원으로부터 물 공급이 차단되는 간접고립지역(unintended isolation)으로 구분할 수 있다. 간접고립지역은 차폐된 직접고립지역으로 인해 수원으로부터의 유일한 용수공급 노선이 차단되어 발생한다. 관 파손에 의한 단수 피해를 현실적으로 모의하기 위해서는 밸브위치에 따른 단수구역을 정확히 산정할 필요가 있다. 단수구역은 파손관의 위치뿐만 아니라 차단 밸브의 개수 및 위치에 따라 달라진다. 따라서, 관 파손에 의한 단수피해를 최소화하기 위해서는 각 관로의 파손확률과 절점의 중요도를 고려하여, 적절한 밸브의 위치를 선정해야 한다. 본 연구에서는 관 파손에 따른 단수상황을 모의하여 파손 관에 의한 직, 간접 단수구역을 탐색한 후, 단수용량을 파악하고 이를 최소화하기 위한 밸브의 적정 위치를 최적화 알고리즘을 이용하여 결정하는 방안을 제시하였다.

  • PDF

Analysis of Burst Detection Based on Adjustable Sampling Interval (가변적 샘플링 기반한 누수탐지 분석)

  • Kim, Seong Won;Jeong, An Chul;Jung, Kwan Sue
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.292-292
    • /
    • 2015
  • 최근 상수관망의 물 공급 과정에서 여러 가지 원인으로 인해 물의 손실에 따른 비용손실이 발생하고 있다. 급수시스템의 경우에는 파열 및 누수발생과 관련되어 사용되는 비용은 분실되는 물의 직적비용, 급수시스템 수리에 따른 공사비용, 공급중지와 관련된 사회적 비용이 있다. 파열 및 누수를 신속하게 감지하는 것은 물 손실에 의해 발생하는 직접 및 간접비용을 줄일 수 있다. 그러나 국내의 경우 정기적으로 매년 1회 시행되는 상수관로에 대한 누수탐지작업으로 신속한 감지 및 즉각적인 대처를 할 수 없는 실정이다. 본 연구에서는 수도관에서 발생되는 파열 및 누수를 탐지하기 위하여 블록 유입부에 설치된 유량계의 샘플링 간격의 영향에 대한 연구를 실시하였다. 적응칼만필터 알고리즘을 이용한 가변 샘플링 간격은 최대 최소 샘플링 간격과 정규화된 잔차의 상한값과 하한값 도입하여 제시하였다. 샘플링 간격의 효과를 강조하기 위해 사인 곡선, 사다리꼴 파열, 불규칙 잡음으로 구성된 가상의 유량 데이터로 알고리즘에 대한 검증실험을 진행하였고 실험 결과 샘플링 간격이 길수록 긴 시간 동안 누수 및 파열에 대한 작은 잔차를 발생시켰다. 모의실험결과 샘플링 주기를 변경함으로써 분석에 필요한 유량 데이터의 샘플수를 크게 줄일 수 있었다.

  • PDF

A pressure based flow velocity estimation technique using inverse impedance for simple pressurized pipeline systems (피압 단순 관로 체제에서의 인버스 임피던스를 이용한 수압기반 유속추정기술)

  • Lee, Jeongseop;Ko, Dongwon;Choi, Dooyong;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.219-228
    • /
    • 2022
  • In this study, we propose a flow velocity evaluation scheme based on pressure measurement in pressurized pipeline systems. Conservation of mass and momentum equations can be decomposed into mean and perturbation of pressure head and flowrate, which provide the pressure head and flowrate relationship between upstream and donwstream point in pressurized pipeline system. The inverse impedance formulations were derived to address measured pressure at downstream to evaluation of flow velocity or pressure at any point of system. The convolution of response function to pressure head in downstream valve provides the flow velocity response in any point of the simple pipeline system. Simulation comparison between traditional method of characteristics and the proposed method provide good agreements between two distinct approaches.

An Experimental Study on Ground Reinforcement Effect of Concrete and Expansion Mat for Prevention of Buried Pipe Damage (지중매설관 손상 방지를 위한 콘크리트매트와 팽창매트의 지반보강효과에 관한 실험적 연구)

  • Park, Jeong-Jun;Shin, Heesoo;Yuu, Jungjo;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.91-101
    • /
    • 2019
  • Recently, small-scale excavation like ground cavity restoration and buried pipe replacement works are being carried out in urban area, in order to improve living convenience. This paper describes experiment results on the ground reinforcement method that can reduce the buried pipe damage, when the differential settlement occurred due to poor compaction of ground below the buried pipe. Plate load tests were conducted to evaluate a reinforcement effect of ground using concrete mat and expansion mat in the ground below the buried pipe. The results showed that the stress reduction ratio by concrete mat and expansion mat according to the surcharge load was about 46%~48% and 39%~42%, respectively. Therefore, the differential settlement of the buried pipe and the ground deformation below the buried pipes were reduced by the reinforcement effect of the concrete mat and expansion mat. This means that it is possible to prevent a buried pipe damage due to underground cavity and ground subsidence, if concrete mat and expansion mat are reinforced in the ground below the buried pipe or on the ground between the buried pipes.

Improvement on Surveying Performance Evaluation for Public Surveying of Underground Facilities (지하시설물의 공공측량 성과심사 방법 개선에 관한 연구)

  • Jung, Choong Ho;KIM, Chong-Mun;KIM, Ki-Su;CHOI, Yun-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.15-23
    • /
    • 2019
  • When the public surveying system was introduced in 1961, large scale surveying performances, such as infrastructure construction work, were dominant. However, due to changes in the environment, most of the current surveying performances focused on small scale underground facilities. The method of surveying underground facilities is as follows: "method of measurement before refilling after burying the pipeline" and "method of using exploration after refilling." There are advantages and disadvantages to each method. It became difficult to obtain the accuracy of the location of the underground facilities due to the fact that there were sections of the pipeline that had not been observed through exploration. Therefore, the 2017 performance evaluation regulations were revised. The revision included the addition of the "Underground Facilities Creation Period," a system that allows for surveys to be evaluated based on actual measurements. However, in this particular field, concerns about the advantages of exploration and the purpose of this study was to investigate the background and purpose of the limitations of the survey have been continuously raised. The purpose of this study was to investigate the background and purpose of the public surveying system and to identify the proportion of underground facilities surveying in comparison to public surveying. This study conducted surveys on the implementers of public surveying and those who did the actual surveying. The researcher has summarized the improvements that incorporate the analysis results and the field comments in the revised performance evaluation regulations in 2017.

A Study on the cleansing of water data using LSTM algorithm (LSTM 알고리즘을 이용한 수도데이터 정제기법)

  • Yoo, Gi Hyun;Kim, Jong Rib;Shin, Gang Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.501-503
    • /
    • 2017
  • In the water sector, various data such as flow rate, pressure, water quality and water level are collected during the whole process of water purification plant and piping system. The collected data is stored in each water treatment plant's DB, and the collected data are combined in the regional DB and finally stored in the database server of the head office of the Korea Water Resources Corporation. Various abnormal data can be generated when a measuring instrument measures data or data is communicated over various processes, and it can be classified into missing data and wrong data. The cause of each abnormal data is different. Therefore, there is a difference in the method of detecting the wrong side and the missing side data, but the method of cleansing the data is the same. In this study, a program that can automatically refine missing or wrong data by applying deep learning LSTM (Long Short Term Memory) algorithm will be studied.

  • PDF

Characterization of Repairing Polyurethane for Trenchless Sewer Pipeline (비굴착 하수관로용 폴리우레탄 보수재 특성 평가)

  • Park, Jun-Ha;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3542-3547
    • /
    • 2015
  • There is commonly used the full depth excavation method of sewer pipeline maintenance in Korea. This induces couple of technical and social problems like increase of construction cost and time for excavation and backfill, increase of public complains and delay of traffic, and so force. In order to overcome these problems, lots of laboratory tests were carried out for sewer pipeline of maintenance materials with trenchless methods. The testing materials are liquid and hardened polyurethane, and polyurethane CIPP. The lab tests were followed by Korean Standard. There are no side effects, like harmless to the human body and air pollution with stink. Judging from the limited test results, all the items tested were satisfied the KS criteria.