• Title/Summary/Keyword: 관군

Search Result 90, Processing Time 0.027 seconds

Experimental investigation of heat transfer enhancement in horizontal bundle tubes on absorber (수평관군 흡수기의 전열촉진에 관한 실험적 연구)

  • Moon, Choon-Geun;Seol, Won-Sil;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.328-334
    • /
    • 2000
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different horizontal tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare tube, floral tube, hydrophilic tube. The additive concentration was about $0.05{\sim}5.5mass%$. The heat transfer coefficient was measured as a function of solution flow rate in the range of $0.01{\sim}0.034 kg/ms$. The experimental result were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube.

  • PDF

A study on the JUNG, Dong-Bumb Righteous Army (의병 정동범에 관한 연구)

  • Jung, Jae Keak
    • Convergence Security Journal
    • /
    • v.15 no.6_1
    • /
    • pp.43-48
    • /
    • 2015
  • One of the background reasons of the raise of the voluntary army under the name of justice in 1728, in late Chosun period, was the discontent against the regime at that time. After the King Young-Jo ascended a throne of Chosun dynasty, some people such as Lee In-Jwa and JUNG Hee-Ryang organized rebels and raised a rebellion. At this time of a national crisis, there were people organizing the army of the justice and joining in the battles against the rebels with the royal forces of Chosun dynasty. JUNG Dong-Beum, one of the leaders of voluntary armies of justice, is a good example. For these people playing roles in the army of justice, more follow-up studies should be continued.

Heat Transfer Characteristics of Heat Exchange Module for a Water Tube Type Modular Boiler (모듈형 수관식 보일러를 위한 열교환 모듈의 열전달 특성)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 2012
  • A finned tube type heat exchange module has been proposed for a multi-burner water tube boiler. Fin density and length increase in streamwise direction to equalize the evaporation for each module, which makes it difficult to apply conventional bulk design procedure. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also conducted to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, since the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.

Vibration Characteristics of Heat Exchanger Tube Bundles in Two-Phase Cross-Flow (2상 횡유동을 받는 열교환기 관군의 진동특성)

  • 김범식;박태철
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.199-208
    • /
    • 1994
  • Two-phase cross-flow exists in many shell-tube heat exchangers such as nuclear steam generators, condensers and reboilers. An understanding of damping and of flow-induced vibration excitation mechanisms in necessary to avoid problems due to excessive tube vibration. In this paper, we present the results of experiments on normal-triangular tube bundles of pitch to tube diameter ratio, p/d, 1.22, 1.32 and 1.47. The bundle were subjected to air-water mixtures to simulate realistic mass fluxes and vapour qualities corresponding to void fractions from 5 to 99%. Damping, fluidelastic instability and turbulence- induced excitation are discussed. The behaivior of damping and two vibration mechanisms are different for intermittent flows from for bubbly flows. The effect of pitch to tube diameter ratio and void fraction is dominant on damping and fluidelastic instability.

  • PDF

HEAT TRANSFER ON THE COMBUSTION CHAMBER OF A WATER TUBE TYPE BOILER WITH MULTIPLE BURNERS (다중 버너를 채택한 수관식 산업용 보일러 연소실의 열전달 특성)

  • Ahn, J.;Hwang, S.;Kim, J.J.;Kang, S.B.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2009
  • Operating medium or large scale industrial boilers in partial load condition, the burner should undergo the off-design points resulting in poor exhaust gas characteristics. To obtain the stable turn down performance, two or more burners can be used for the industrial boiler. In case multiple burners are adopted, the heat transfer can be enhanced by arranging the burners properly. In the present study, numerical simulations have been conducted for the combustion chamber of a 2 t/h class industrial boiler in order to clarify the heat transfer characteristics at the combustion chamber.

Fluid-elastic Instability in a Tube Array Subjected to Two-Phase Cross Flow (2 상 횡 유동장에 놓인 관군의 유체탄성불안정성)

  • Sim, Woo-Gun;Park, Mi-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.2
    • /
    • pp.124-132
    • /
    • 2009
  • Experiments have been performed to investigate fluid-elastic instability of tube bundles, subjected to twophase cross flow. Fluid-elastic is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to the cross flow. The test section consists of cantilevered flexible cylinder(s) and rigid cylinders of normal square array. From a practical design point of view, fluid-elastic instability may be expressed simply in terms of dimensionless flow velocity and dimensionless mass-damping parameter. For dynamic instability of cylinder rows, added mass, damping and the threshold flow velocity are evaluated. The Fluid-elastic instability coefficient is calculated and then compared to existing results given for tube bundles in normal square array.

Effect of domain size on flow characteristics in simulating periodic obstacle flow (주기적인 경계조건을 사용하는 수치모사에서 계산영역 크기의 영향)

  • Choi, Choon-Bum;Jang, Yong-Jun;Han, Seok Youn;Kim, Jin-Ho;Yang, Kyung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2477-2482
    • /
    • 2008
  • Effect of computational domain size in simulating of periodic obstacle flow has been investigated for the flow past tube banks. Reynolds number, defined by freestream velocity (U) and cylinder diameter (d), was fixed as 200, and center-to-center distance (P) as 1.5d. In-line square array was considered. Drag coefficient, lift coefficient and Strouhal number were calculated depending on domain size. Circular cylinders were implemented on a Cartesian grid system by using an immersed boundary method. Boundary condition is periodic in both streamwise and lateral directions. Previous studies in literature often use a square domain with a side length of P, which contains only one cylinder. However, this study reveals that size is improper. Especially, RMS values of flow-induced forces are most sensitive to the domain size.

  • PDF

Absorption of Water Vapor into an Absorbing Binary Liquid Film Falling over a Horizontal Tube Bank (수평원관군상(水平圓管群上)의 이원흡수용액유동(二元吸收溶液流動)에 의(依)한 전달흡수특성(傳達吸收特性))

  • Kim, S.;Kim, Y.I.;Seo, S.C.;Hwang, D.K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.583-589
    • /
    • 1988
  • Condensation of water vapor into an absorbent liquid of LiBr-water solution falling over a bank of water cooled horizontal tubes was investigated theoretically. The governing conservation equation for a re-defined physical transport phenomena were solved numerically using a finite difference method. Raw parameters were used in this study, since reliable experimental data is required prior to a dimensionless parametric study. The average values of wall heat transfer coefficient and interfacial absorption rate were defined to see the system performance. Other parameters include tube diameter, streamwise coordinate (and number of tubes in row), mass flow rate, and the wall temperature. The effects of these quantities on the absorption processes and suggestions for a rational system design have been presented.

  • PDF

Heat Transfer Module for Multi-Burner Water Tube Boiler: 0.5 t/h Class Model Simulation (다중버너 수관식 보일러를 위한 전열모듈의 열전달 특성: 0.5 t/h급 모형 수치해석)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.528-533
    • /
    • 2007
  • A finned tube type heat transfer module has been proposed for a multi-burner water tube boiler. Fins change their geometry along the streamwise direction to maximize the performance, which makes it difficult to apply conventional bulk analysis. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also performed to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, where the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.

  • PDF

A Study on the Heat Storage Characteristics of a Latent Heat Storage Tank with Shell and Tube Type (셀-튜브형 잠열축열조의 축열특성에 관한 연구)

  • 권영만;김경우;모정하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.745-754
    • /
    • 2000
  • An experimental study has been carried out in order to investigate the heat storage characteristics for a latent heat storage tank with horizontal shell and tube type. The heat storage tank consists of cylindrical capsules with a staggered tube bank. The effects of flow rates and initial temperature differences on the melting time and heat storage rates are examined. It is found that the melting time decreases with increase of the flow rates and initial temperature differences. Results also show that the time-averaged overall heat transfer coefficients increase in proportion to the increase of flow rates and initial temperature differences.

  • PDF