• Title/Summary/Keyword: 과학적 연구방법론

Search Result 936, Processing Time 0.032 seconds

Examination of the Current Situations of Security Dogs and it's Development Plans (경호탐지견의 운용실태 및 발전방안)

  • Park, Hyung-Kyu;Kim, Doo-Hyun
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.215-234
    • /
    • 2007
  • Our country security industry 1960's service expense of the beginning U.S. army unit it accomplishes the growth which is quick with start, currently about 2,500 triumph the security enterprises which it goes over are being active. But the majority in these enterprise about lower cotton can a forever characteristic with pressure and the manpower civil official ability insufficient back of faithlessness management and capital power. To sleep with afterwords it presents the security dogs deployment plan for an efficient security together from the research which it sees hereupon and it does. First, it cultivates the domestic mountain progress dog which is a breed which is suitable with the security dogs and the shovel flesh dog back with the security dogs. Specially the Jindo of the breed which is excellent training which is suitable in task of the security dogs it leads and if it uses appropriately, it industrializes our specific the Jindo and protection there is a possibility of getting the effect which falls to also the gist which it rears rightly. It cultivate the second, security dogs and it magnifies training. The security dogs consequently is it will be able to accomplish the task above 2 branches to training method. Namely, after finishing obedience training, it is to be in security activity it will execute guard or detection back special training which is suitable in task and it will be able to commit. Third, it uses the security dogs which is trained rightly in task. The security dogs the adult escorts, facility expense, the explosive and narcotic drug detection, it will be able to use with the other blind man guidance dogs back. The narcotic drug detection dogs which currently is used specially technique intelligence anger, when considering the tendency of the narcotic drug smuggling offense field which becomes diversification that the role very it is important is a possibility of saying at day. It cultivate a fourth, escort relation specialty manpower and it improves the breed of the security dogs. The hazard which cultivate the security dogs use necessary personnel the breed of security dogs, the security dogs training center it opens the security crane relation subject of the college which stands and (university) it improves it establishes and training which is suitable in task it is to do to execute letting in the training map company. Specially, the hazard which improves the breed of security dogs in the progress mind quality which stands against the portion where the breed improvement is demanded as the portion where the internal organs research and investment are necessary sees. The security dogs compares in labor cost and the expense holds few, if it uses the our specific domestic dogs it will be able to use efficiently in the task which is various it solves the multi branch plans for wisly with the security dogs industrial development security of course contemporary history sliced raw fish sees demands compared to being immediacy and the life which is happy business the place where it does it sees it will be able to contribute a lot as.

  • PDF

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Analysis of Changes in Tree Height-Diameter Allometry for Major Tree Species in South Korea (우리나라 주요 수종의 수고-직경 상대생장 변화 분석)

  • Moonil Kim;Taejin Park;Youngjin Ko;Go-Mi Choi;Soonchul Son;Yejun Kang;Jaehee Yoo;Minkyeong Kim;Hyeonji Park;Woo-Kyun Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.1
    • /
    • pp.71-82
    • /
    • 2023
  • Forest biomass is used as a representative indicator of forest size, maturity, and productivity. Therefore, quantitative evaluation is important for management and harvest as well as the evaluation of ecosystem functions and services including CO2 absorption. The allometric equation is a widely used method for estimating the value of each component through the relative growth rate of plants. Recently, studies indicated that the relative growth of trees is changing because of the increased CO2 concentration in the atmosphere and the resulting climate change, raising the need to review the previously developed relative growth models and coefficients. In this study, the height-diameter at breast height (DBH) relationships of four major tree species in Korea [(Pinus densiflora (PD), Larix kaempferi (LK), Quercus variabilis (QV), and Quercus mongolica (QM)] were analyzed using the 5th-7th National Forest Inventory (NFI) data. Furthermore, these results were compared with the present yield table from the National Institute for Forest Science. This analysis revealed that the expected height for the same DBH increased as the NFI progressed. For example, in model analysis, the expected heights for PD, LK, QV, and QM for DBH of 25 cm were 12.48, 19.17, 14.47, and 13.19 m, respectively, in the 5th NFI data. In the 7th NFI data, these values were estimated as 13.61 (+9.1%), 21.58 (+12.7%), 15.76 (+8.9%), and 13.93 m (+5.6%), respectively. These results indicate that the major tree species in South Korean forests currently are more vigorous in height growth than in diameter growth when compared to the height-DBH development trends by tree species identified through past survey data.

A Usability Testing for the Verification of User Mental Model in Using Multifunction Printer (프린터 복합기의 사용자 심성모형 검증을 위한 사용성 평가)

  • Chung, Sung-Jae;Kim, Bong-Gun;Ha, Kwang-Soo;Jung, Hye-Heon;Lim, Bong-Uk
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • This study is about what process and methodology could make UI designer be able to achieve the interface which considers user's mental model through implementing corporate line-up model, when people design an interface between product of multi-function printer and user. The most important concern of UI designers who are dealing with an interface between product and user is how they can make product system image match user's mental model so that users can utilize products without any confusion and discomfort. If concept model which designers bring up and mental model which users expect and recognize could be of one accord, then users can feel ease of use toward products. The understanding and observation for user behavior and use pattern is prerequisite to develop user-centered interface between product and user. However, UI designers do design interface from their own perspective and assumption in many business areas, and users do not react as designers assumed and intended in many cases or examples. This study is to find inappropriate system images against users' mental model on basic function of multi-function printer, and the relationship of system image and user's mental model is diagramed to build up a hypothesis. The hypothesis from this study is validated through evaluation of domestic and international users. In addition, two suggestions to improve usability problems revealed from user test are proposed. The optimal solution is designed based on the result of user evaluation and consideration of many user environments, and then it is implemented to line-up product. In conclusion, this study considers how UI designers can create system image which is close to user's mental model.

  • PDF

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF

Kinetics and Mechanism of Alkalie Hydrolysis of Cinnamonitrile (II) (Cinnamonitrile의 알카리 가수분해(加水分解) 반응(反應)메카니즘 (II))

  • Sung, Nack Do;Chung, Woo Jin;Kwon, Ki Sung;Park, Byung Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.354-364
    • /
    • 1983
  • Confonmation of (Z)-cinnamonitrile have been studied by molecular orbital theoretically using extended Huckel theory(EHT) and CNDO/2 molecular orbital calculation methods. The results indicate that the stability of conformation is(Z)-gauch>(Z)-planar. The rate constants for alkalie hydrolysis of cinnamonitrile at pH 7.0-14.0 range have been determined by ultra-violet spectrophotometry in 50% methanol at $25^{\circ}C$ and the following rate equation which can be applied over wide pH range was obtained; $${\therefore}k=({\frac{1.41{\times}10^{-14}+1.21{\times}10^7/[H_3O^+]}{2.65{\times}10^{-7}+1.64/[H_3O^+]})+9.14{\times}10^9/[H_3O^+]$$ The rate equation reveals that, at pH 7.0-10.0, the reaction is initiated by the addition of water molecule to unsaturated cabon-carhon double bond of cinnamonitrile and ${\alpha}C-{\beta}C$ bond scission follow subsequently in neutral and alkalie media. At pH 12.0-14.0, in strong alkalie solution, that so-called Michael type nucleophilic addition that the over-all rate constants is only dependent upon the concentration of hydroxide ion occurs competitively and are very complicated. Hence, the reaction mechanism of alkalie hydrolysis of cinnamonitrile which did not carefully before can be fully explained.

  • PDF

The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF

The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound (초음파상 복합성 낭성 유방 종괴의 조직 검사 결과에 관한 연구)

  • Kang, Hye-Kyoung;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Purpose: We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. Objects and methods: This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. Results: The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). Conclusion: The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  • PDF

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF