• Title/Summary/Keyword: 과열 증기

Search Result 89, Processing Time 0.023 seconds

Experimental Study on the Wear Effects of a Brush Seal in DN 2.5million in a 250℃ High - temperature Steam Environment (DN 250만 250℃고온 스팀환경에서 운전되는 단열 브러쉬 실 마모효과에 관한 실험적 연구)

  • Ha, YunSeok;Ha, TaeWoong;Lee, YoungBok
    • Tribology and Lubricants
    • /
    • v.35 no.2
    • /
    • pp.99-105
    • /
    • 2019
  • This study presents an experimental investigation of the wear and oxidation of the bristles of a brush seal in a super-heated steam environment. We construct a model reflecting normal force and radial interference to predict the amount of wear. To monitor the volume loss of the bristle induced by the swirl phenomenon of the rotor, we measure the clearance between the rotor and the brush seal by using a non-contact 3-D device. We calculate the area by using the area-wise measurement method. Considering the obvious brush seal wear variables, we use two disks with different roughness($Ra=0.1{\mu}m$ and $100{\mu}m$) to determine the effect of roughness on wear. Considering an actual steam turbine, we utilize a steam generator and super-heater to generate a working fluid (0.95MPa, 523.15K) that has high kinetic energy. We observe the abrasion of the bristles in the hot steam environment through a scanning electron microscope image. This study also conducted energy dispersive X-ray (EDX) analysis for a qualitative evaluation of local chemistry. The results indicate that the wear and elimination of bristles occur on the disk with high roughness, and the weight increases due to oxidation. Furthermore these results, reveal that the bristle oxidation is accelerated more under super-heated steam conditions than under conditions without steam.

Evaluation of perfluorinated compounds removal performance and automatic regeneration performance by activated carbon adsorption process (활성탄 흡착공정에 의한 과불화화합물의 제거 및 활성탄 자동재생 성능 평가)

  • Jung, Jinho;Lee, Sanghoon;Yun, Wonsang;Choi, Daehee;Jung, Jinyoung;Han, Ihnsup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.2
    • /
    • pp.121-134
    • /
    • 2022
  • In this study, the removal efficiency of PFCs(perfluorinated compounds) in the GAC(granule activated carbon) process based on the superheated steam automatic regeneration system was investigated in laboratory scale and pilot-scale reactor. Among PFCs, PFHxS(perfluorohexyl sulfonate) was most effectively removed. The removal efficiency of PFCs was found to be closely related to the EBCT, and the removal efficiencies of PFOA(perfluorooctanoic acid), PFOS(perfluorooctyl sulfonate), and PFHxS were 43.7, 75, and 100%, respectively, under the condition of EBCT of 6 min. Afterward, PFOA, PFOS, and PFHxS exhibited the earlier breakthrough time in the order. After that, GAC was regenerated, and the removal efficiency of the PFCs before and after regeneration was compared. As a result, it was shown that the PFCs removal efficiency in the regenerated GAC process were higher, and that of PFOA was improved to 75%. The findings of this study indicate the feasibility of the superheated steam automatic regeneration system for the stable removal of the PFCs, and it was verified that this technology can be applied stably enough even in field conditions.

LOCA Analysis and Development of a Simple Computer Code for Refill-Phase Analysis (냉각재 상실사고 분석 및 재충진 단계해석용 전산코드 개발)

  • Ree, Hee-Do;Park, Goon-Cherl;Kim, Hyo-Jung;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.200-208
    • /
    • 1986
  • The loss of coolant accident based on a double-ended cold leg break is analyzed with the discharge coefficient (Ca) of 0.4. This analysis covers the whole transient period from the start of depressurization to the complete refilling of the core by using RELAP4/MOD6-EM and RELAP4/ MOD6-HOT CHANNEL for the system thermal-hydraulics and the fuel performance during the blowdown phase respectively, and RELAP4/MOD6-FLOOD and TOODEE2 during the reflood phase. A simple analytical method has been developed to account for the lower plenum filling by approximating steam-water countercurrent flows and superheated wall effects at the downcomer during the refill period. Based on the informations. at the time of EOB (end-of-bypass), the refill duration time and the initial reflooding temperature were estimated and compared with the results from the RELAP4/MOD6, resulting in a good agreement. In addition, some parametric studies on the EOB were performed. The form loss coefficient between upper head and upper downcomer was found to be sensitive to the occurrence of the spurious EOB. Appropriate form loss coefficients should be taken into account to avoid the flow oscillations at the downcomer. The analyses with the six and three volume core nodalizations, respectively, show much similar trends in the system thermal-hydraulic performance, but the former case is recommended to obtain good results.

  • PDF

Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture (NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구)

  • Kim, Ji-Young;Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • This research aims todevelopa compression/absorption hybrid heat pump system using an $NH_3/H_2O$ as working fluid.The heatpump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a desorber, a desuperheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above $90^{\circ}C$ using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangementof the plate heat exchangers with regard tothe concentration and distribution at the inlet of the absorber.

Parametric Analysis of the Performance of Water Recirculated Oxy-Fuel Power Generation Systems (물을 재순환하는 순산소 발전 시스템의 작동조건 변화에 따른 성능해석)

  • Park, Byung-Chul;Sohn, Jeong-Lak;Kim, Tong-Seop;Ahn, Kook-Young;Kang, Shin-Hyoung;Lee, Young-Duk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.35-43
    • /
    • 2010
  • In this study, an ideal water-recirculated oxy-fuel power generation system is proposed. The results of parametric studies of the performance characteristics of the system are discussed. For a given choice of the turbine inlet temperature, the turbine, which produces power, can be either a gas or a steam turbine. For maximum efficiency, the turbine inlet temperature is selected as the level of state-of-the-art gas turbines and the reheat cycle may be adopted not only to enhance the turbine power but also to maintain dryness of the water with a turbine exhaust temperature that is as high as possible. To obtain a low condensation temperature for a high purity of $CO_2$, a relatively low pressure expansion process may be added. Finally, the performance of the water-recirculated oxy-fuel power generation system is discussed with reference to various operating parameters and system configurations. The optimal operating conditions for high performance and a high purity of $CO_2$ are proposed.

Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture (천연혼합냉매를 이용한 압축/흡수식 고온히트펌프의 실험적 연구)

  • Kim, Ji-Young;Park, Seong-Ryong;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Min-Sung;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1367-1373
    • /
    • 2011
  • This research concerns the development of a compression/absorption high-temperature hybrid heat pump that uses a natural refrigerant mixture. Heat pumps based on the compression/absorption cycle offer various advantages over conventional heat pumps based on the vapor compression cycle, such as large temperature glide, temperature lift, flexible operating range, and capacity control. In this study, a lab-scale prototype hybrid heat pump was constructed with a two-stage compressor, absorber, desorber, desuperheater, solution heat exchanger, solution pump, liquid/vapor separator, and rectifier as the main components. The hybrid heat pump system operated at 10-kW-class heating capacity producing hot water whose temperature was more than $90^{\circ}C$ when the heat source and sink temperatures were $50^{\circ}C$. Experiments with various $NH_3/H_2O$ mass fractions and compressor/pump circulation ratios were performed on the system. From the study, the system performance was optimized at a specific $NH_3$ concentration.

A study on the residual stress at the weld joint of 2.25Cr-1.6W heat resistant steel (보일러용 배관재 2.25Cr-1.6W계 내열강의 용접부 응력 해석)

  • Lee, Y.S.;Lee, K.W.;Lee, J.B.;Kim, Y.D.;Kong, B.W.;Ryu, S.H.;Kim, J.T.;Kim, B.S.;Jang, J.C.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.62-62
    • /
    • 2009
  • 석탄화력발전소의 CO2배출량 감소와 고효율, 대용량화로 인해 초초임계압(USC:Ultra Super Critical) 화력발전소의 건설이 증가하고 있다. USC 발전소는 효율향상을 위한 증기온도와 압력의 상승 때문에 보일러 고온고압부에 기존의 소재에 비해 고온강도와 내산화성의 재료물성이 향상된 신소재 적용이 불가피하다. 특히 사용된 신소재 중에서 보일러 본체를 구성하는 수냉벽관(Water wall), 과열기와, 재열기용 튜브 및 후육부인 헤더와 배관재로 기존의 2.25Cr-1Mo강을 개량한 2.25Cr-1.6W계 내열강이 적용되고 있다. 2.25Cr-1.6W강은 SMI와 MHI가 공동개발한 소재로 1995년 튜브제품이, 1999년에 단조, 파이프재, 플레이트제품이 ASME code case로 등재되었고, 2009년 ASME code case 2199-4로 개정되어 사용 중이다. 이 소재는 2.25Cr-1Mo강에 고온강도 개선을 위해 석출강화효과가 있는 V과 Nb을 첨가하였고, 탄화물의 열적안정성과 고용강화효과 증대를 위해 W을 첨가하였다. 그리고 제작성과 용접성 및 재료의 인성 향상을 위해 B첨가와 C함량을 낮추었다. 합금성분의 첨가와 조정에 의해 고온강도는 개선되었지만, 보일러 설치 및 보수를 위한 용접과정에서 용접금속과 CGHAZ(Coarse Grain HAZ)에서 용접균열이 발생하였다. 대부분의 용접균열은 용접결함이나 고온 혹은 저온균열이 아닌 2.25Cr-1.6W계강의 강도 개선을 위해 첨가한 V과 Nb이 용접후열처리 도중 입내에 MX형태의 미세석출로 입내를 강화시킴으로서 발생한 재열균열 민감성 증대에 기인된 것으로 판단된다. 이에 본 연구에서 용접 및 후열처리 과정에서 용접금속과 HAZ에서 발생하는 용접금속의 응력분포를 전산해석을 통해 확인하고 실제 후육파이프 용접부에서 잔류응력을 측정해 비교하였다. 용접부 응력분포는 SYSWELD 프로그램을 사용해 해석을 수행하였고, 발전소 실배관재의 용접부 응력측정은 수평부 측정이 용이하도록 지그를 부착한 Potable 잔류응력측정기를 사용해 Hole Drilling Method(HDM)를 적용하여 잔류응력을 측정하였다. 해석 결과 CGHAZ부위의 잔류응력이 용접금속과 기타 부위에 비해 높은 응력분포를 나타냈으며, 이는 CGHAZ와 용접용융선 부근에서 균열이 발생하는 실제값과 일치하는 결과를 보였다. 실제 배관재 용접부에서 측정한 잔류응력값은 항복응력의 약 50% 이하 응력값을 나타냈다. 배관 구조에 기인한 시스템응력의 영향을 제거하기 위해 배관재 용접부를 중심으로 양끝단을 절단 후 용접부에서 측정한 응력은 항복응력 대비 25%수준의 낮은값을 보였다. 그러나 배관재가 장기간 고온환경에 노출되었고 용접금속 내부의 균열이 발생한 상태에서 측정하였기 때문에 용접잔류응력은 상당부분 해소되어 상대적으로 낮은 응력값이 얻어진 것으로 판단된다.

  • PDF

Development and Quality Characteristics of Superheated Steam Roasted Small Yellow Croaker Larimichthys polyactis, Sweet Potato Salad and Tomato Mousse for Senior-friendly Seafood (참조기(Larimichthys polyactis)를 활용한 고령친화식품용 과열증기구이, 고구마 샐러드 및 토마토무스의 개발 및 품질특성)

  • Park, Sun Young;Kang, Sang-In;Cho, Hye Jeong;Kim, Poong-Ho;Kim, Jin-Su
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.645-654
    • /
    • 2022
  • This study was conducted to prepare superheated steam roasted (SSR) small yellow croaker Larimichthys polyactis sweet potato salad (SPS) and tomato mousse (TM), as senior-friendly seafoods (SFS) and to examine their quality characteristics. The hardness values of SSR, SPS and TM were 110.5×1.03, 22.4×1.03 and 14.5×1.03 N/m2, respectively. The nutritional properties of SSR, SPS and TM were 22.4, 6.7 and 10.2 g/100 g, respectively, for protein, 97.01, 3.40 and 17.00 ㎍/100 g, respectively, for vitamin A, 10.26, 2.79 ㎍/100 g and not detected (ND), respectively, for vitamin D, 60.68 mg/100 g, ND and 4.17 mg/100 g, respectively, for vitamin C, 0.18, 0.10 and 0.33 mg/100 g, respectively, for riboflavin 24.28, 10.91 and 13.77 mg/100 g, respectively, for niacin, 76.3, 53.0 and 48.5 mg/100 g, respectively, for calcium, 258.2, 231.3 and 145.2 mg/100 g, respectively, for potassium, and ND, 0.70 mg/100 g and ND, respectively, for dietary fiber. Escherichia coli was not detected in any of the products. These results suggested that the products should be classified as step 1 for SSR, step 2 for SPS and step 3 for TM based on the SFS standard of the Korean industrial standards. Moreover, the nutritional and physical properties of the foods were improved.

Effect of Freezing and Thawing Condition on the Physical Characteristics of Blanched Bean Sprouts as Home Meal Replacement (냉.해동 조건에 따른 간편편이식 콩나물의 물리적 품질 변화)

  • Jang, Min-Young;Jung, You-Kyoung;Min, Sang-Gi;Cho, Eun-Kyung;Lee, Mi-Yeon
    • Culinary science and hospitality research
    • /
    • v.20 no.6
    • /
    • pp.235-244
    • /
    • 2014
  • The purpose of this study was to investigate the effect of freezing and thawing rate on the physical properties of soybean sprouts to improve the quality of processed soybean sprouts during distribution and storage. Cooked soybean sprouts were frozen by air-blast freezing (ABF) system at $-45^{\circ}C$ or natural air convection freezing (NCF) system at $-24^{\circ}C$, then thawed using microwave oven by varying output power (0, 400, 800 and 1,000 W) until $75^{\circ}C$. The quality of soybean sprouts was measured by the water content, hardness and springiness. In addition, the internal microstructure of soybean sprouts was observed by optical microscope. For results, water content of soybean sprouts thawed by 1,000 W in a microwave showed the lowest value after natural air convection freezing. Springiness of soybean sprouts thawed by all amounts of output power was decreased in comparison with control. Hardness was increased only in soybean sprouts thawed by 1,000 W after air-blast freezing. However the gaps between springiness and hardness were relatively small with control at 1,000 W thawing, after air-blast freezing. Internal microstructure of the soybean sprouts was more damaged as freezing and thawing time were increased. In conclusion, high freezing and thawing rate might improves the quality of soy bean sprout, and IQF freezing and 1,000 W of microwave thawing appears to be the optimum condition for frozen HMR production. From the results freezing and thawing process parameters might can be use as quality control parameters as various type of sprout products processing.