• Title/Summary/Keyword: 과도

Search Result 207,939, Processing Time 0.183 seconds

Phase Equilibria of the System Pd-Sb-Te and Its Geological Implications (팔라듐-안티몬-테루르 계(系)의 상평형(相平衡)과 지질학적(地質學的) 의의(意義))

  • Kim, Won-Sa;Chao, George Y.
    • Economic and Environmental Geology
    • /
    • v.26 no.3
    • /
    • pp.327-335
    • /
    • 1993
  • Phase relations in the system Pd-Sb-Te were investigated at $1000^{\circ}$, $800^{\circ}$, and $600^{\circ}C$, using the sealed-capsule technique; the quenched products were studied by reflected light microscopy, X-ray diffraction, and electron microprobe analysis. At $1000^{\circ}C$, the solid phases Pd, $Pd_{20}Sb_7$, $Pd_8Sb_3$, $Pd_{31}Sb_{12}$, and $Pd_5Sb_2$ are stable with a liquid phase that occupies most of the isothermal diagram. Additional solid phases at $800^{\circ}C$ are $Pd_5Sb_3$, PdSb, $Pd_8Te_3$, $Pd_7Te_3$, and a continuous $Pd_{20}Te_7-Pd_{20}Sb_7$ solid solution becomes stable. At $600^{\circ}$, $PdSb_2$, $Pd_{17}Te_4$, $Pd_9Te_4$, PdTe, $PdTe_2$, $Sb_2Te_3$, and Sb and continuous PdSb-PdTe and $PdTe-PdTe_2$ solid solutions are stable. All the solid phases exhibit solid solution, mainly by substitution between Sb and Te to an extent that varies with temperature of formation. The maximum substitution (at.%) of Te for Sb in the Pd-Sb phases is: 44.3 in $Pd_8Sb_3$, 52.0 in $Pd_{31}Sb_{12}$, 46.2 in $Pd_5Sb_2$ at $800^{\circ}C$; 15.3 in $Pd_5Sb_3$, 68.3 in $PdSb_2$ at $600^{\circ}C$. The maximum substitution (at.%) of Sb for Te in the Pd-Te phases is 34.5 in $Pd_5Sb_3$ at $800^{\circ}C$, and 41.6 in $Pd_7Te_3$, 5.2 in $Pd_{17}T_4$, 12.4 in $Pd_9Te_4$, and 19.1 in $PdTe_2$ at $600^{\circ}C$. Physical properties and X-ray data of the synthetic $Pd_9Te_4$, PdTe, $PdTe_2$, $Pd_8Sb_3$, PdSb, and $Sb_2Te_3$ correspond very well with those of telluropalladinite, kotulskite, merenskyite, mertieite II, sudburyite, and tellurantimony, respectively. Because X-ray powder diffraction data consistently reveal a 310 peak ($2.035{\AA}$), the $PdSb_2$ phase is most probably of cubic structure with space group $P2_13$. The X-ray powder pattern of a phase with PdSbTe composition, synthesized at $600^{\circ}C$, compares well with that of testibipalladite. Therefore, testibiopalladite may be a member of the $PdSb_2-Pd(Sb_{0.32}Te_{0.68})$ solid solution series which is cubic and $P2_13$ in symmetry. Thus the ideal fonnula for testibiopalladite, presently PdSbTe, must be revised to PdTe(Sb, Te). Borovskite($pd_3SbTe_4$) has not been found in the synthetic system in the temperature range $1000^{\circ}-600^{\circ}C$.

  • PDF

Element Dispersion and Wall-rock Alteration from Daebong Gold-silver Deposit, Republic of Korea (대봉 금-은광상의 모암변질과 원소분산 특성 연구)

  • Yoo, Bong-Chul;Chi, Se-Jung;Lee, Gil-Jae;Lee, Jong-Kil;Lee, Hyun-Koo
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.713-726
    • /
    • 2007
  • The Daebong deposit consists of gold-silver-bearing mesothermal massive quartz veins which fill fractures along fault zones($N10{\sim}20^{\circ}W,\;40{\sim}60^{\circ}SW$) within banded gneiss or granitic gneiss of Precambrian Gyeonggi massif. Ore mineralization of the deposit is composed of massive white quartz vein(stage I) which was formed in the same stage by multiple episodes of fracturing and healing and transparent quartz vein(stage II) which is separated by a major faulting event. The hydrothermal alteration of stage I is sericitization, chloritization, carbonitization, pyritization, silicification and argillization. Sericitic zone occurs near and at quartz vein and includes mainly sericite, quartz, and minor illite, carbonates and epidote. Chloritic zone occurs far from quartz vein and is composed of mainly chlorite, quartz and minor sericite, carbonates and epidote. Fe/(Fe+Mg) ratios of sericite and chlorite range 0.36 to 0.59($0.51{\pm}0.10$) and 0.66 to 0.73($0.70{\pm}0.02$), and belong to muscovite-petzite series and brunsvigite, respectively. Calculated $Al_{IV}-Fe/(Fe+Mg)$ diagrams of sericite and chlorite suggest that this can be a reliable indicator of alteration temperature in Au-Ag deposits. Calculated activities of chlorite end member are $a3(Fe_5Al_2Si_3O_{10}(OH){_6}=0.00964{\sim}0.0291,\;a2(Mg_5Al_2Si_3O_{10}(OH){_6}= 9.99E-07{\sim}1.87E-05,\;a1(Mg_6Si_4O_{10}(OH){_6}=5.61E-07{\sim}1.79E-05$. It suggest that chlorite from the Daebong deposit is iron-rich chlorite formed due to decreasing temperature from $T>450^{\circ}C$. Calculated $log\;{\alpha}K^+/{\alpha}H^+,\;log\;{\alpha}Na^+/{\alpha}H^+,\;log\;{\alpha}Ca^{2+}/{\alpha}^2H^+$ and pH values during wall-rock alteration are $4.6(400^{\circ}C),\;4.1(350^{\circ}C),\;4.0(400^{\circ}C),\;4.2(350^{\circ}C),\;1.8(400^{\circ}C),\;4.5(350^{\circ}C),\;5.4{\sim}6.5(400^{\circ}C)\;and\;5.1{\sim}5.5(350^{\circ}C)$, respectively. Gain elements (enrichment elements) during wallrock alteration are $K_2O,\;P_2O_5,\;Na2O$, Ba, Sr, Cr, Sc, V, Pb, Zn, Be, Ag, As, Ta and Sb. Elements(Sr, V, Pb, Zn, As, Sb) represent a potentially tools for exploration in mesothermal and epithermal gold-silver deposits.

The Treatment of Night Soil using Bacillus sp. (Bacillus sp.를 이용한 분뇨처리)

  • 염혜경;이은숙;이병헌;이민규;정일호;김중균
    • Journal of Life Science
    • /
    • v.12 no.6
    • /
    • pp.700-707
    • /
    • 2002
  • To study the characteristics of organic and nutrient removal by Bacillus species at high COD concentration of influent, three lab-scale batch reactors(R1, R2, R3), each of which has different substrate composition, were operated. More than 95% of $NH_4^+$-N and $COD_{cr}$, concentrations were removed under an aerobic condition, and their removal efficiencies were found to be 22.6 and 90.5%(R1), 23.9 and 65.8%(R2), 30.2 and 86.4%(R3), respectively. The removal efficiency of $NH_4^+$-N was high when an enough amount of $NO_3^{-}$-N was supplied, and that of $COD_{cr}$. was low when a high concentration of initial $NO_2^{-}$-N was added. The amount of carbon utilized in denitrification was a little. In all reactors,$NO_3^{-}$-N was removed under an anoxic condition, but in the R3 reactor, 10% of $NO_3^{-}$-N could be removed even undo, an aerobic condition. The removal efficiencies of TN and TP were 41.8 and 49.5%(R1), 40.1 and 35.8%(R2), 47.0 and 57.6%(R3), respectively. Alkalinities destructed under an aerobic condition for each reactor were 4.96, 5.41 and 3.93 mg/L (as $CaCO_3$) per each gram of $NH_4^+$-N oxidized, respectively, while 3.06, 3.17 and 2.60 mg/L (as $CaCO_3$) of alkalinities were produced for each gram of ,$NO_3^{-}$-N reduced to $N_2$. The SOUR were found to be 38.5, 52.7 and 42.0 mg $O_2$/g MLSS/hr, which indicated that Bacillus sp. had a higher cell activity than activated sludge. The OLR and sludge production were estimated to be 0.69 and 0.28(Rl), 0.77 and 0.20(R2), 0.61 kg COD/$m^3$/day and 0.25 kg MLSS/kg COD(R3), respectively. From the N-balance, the highest percentage(40.9%) of nitrogen lost to $N_2$ was obtained in the R3 reactor. From all the results, the possibility of aerobic denitrification Bacillus sp. has been shown and the B3 process seemed to have two advantages: a little amount of carbon was required in denitrification and not much amount of alkalinity was destructed under an aerobic condition.

Effect of OPU (Ovum Pick-Up) Duration on the Rate of Collected Ova and In Vitro Produced Blastocyst Formation (OPU(Ovum Pick-Up) 채란기간이 난자 및 수정란 생산에 미치는 영향)

  • Jin, Jong-In;Kwon, Tae-Hyeon;Choi, Byeong-Hyun;Kim, Sung-Soo;Jo, Hyun-Tae;Kong, Il-Keun
    • Journal of Embryo Transfer
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2010
  • This study was performed to identify the optimal timing for oocyte donor replacement during OPU procedure. OPU was carried out to collect oocytes from every donor at an interval of $3{\sim}4$ days (2 times a week). The collected oocytes were matured in vitro in TCM-199 supplemented with 10% FBS, 10 mg/ml of FSH and 1 mg/ml of estradiol for 24 h. After 24 h of exposure to sperm, the presumptive zygotes were cultured in CR1aa medium supplemented with 4 mg/ml of BSA for 3 days before being changed to CR1aa medium with 10% of FBS for another $3{\sim}4$ days. The mean numbers of retrieved oocytes were remained constantly up to 3 months ($6.0{\pm}0.5$, $6.2{\pm}0.7$, $5.2{\pm}0.6$), but significantly decreased at over 4 to 6 months ($3.7{\pm}0.5$, $2.8{\pm}0.4$, $1.2{\pm}0.2$) (p<0.05). The blastocyst development potential was also very similar rate from 1 to 3 months (37.2%, 40.4% and 44.6%), but significantly decreased from 4 to 6 months (24.8%, 29.3% and 28.6%, respectively) (p<0.05). The production of OPU derived embryos in periods of 1 to 3 months ($2.2{\pm}0.3$, $2.5{\pm}0.3$ and $2.3{\pm}0.4$) were significantly higher than those in 4 to 6 months ($0.9{\pm}0.2$, $0.8{\pm}0.2$ and $0.3{\pm}0.2$, respectively) (p<0.05). In conclusion, the efficient periods for the production of OPU derived embryos was until 4 months, twice per week to produce over 64 transferable embryos and then replace new donor after 3 months use. The best replacement time is 3 months and could be maximized production of OPU derived embryos.

Effect of Early Pregnant Heifer as Donor on the Ovum Pick-Up Derived Oocyte Aspiration and Embryo Production (초기 임신우의 공란우 활용이 초음파 유도 난자 채취 및 수정란 생산에 미치는 영향)

  • Jin, Jong-In;Kwon, Tae-Hyeon;Choi, Byeong-Hyun;Kim, Sung-Soo;Jo, Hyun-Tea;Bang, Jae-Il;Kim, Sam-Chul;Cho, Kyu-Woan;Lee, Jung-Gyu;Kong, Il-Keun
    • Journal of Embryo Transfer
    • /
    • v.26 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • This study was carried out to evaluate the effect of early pregnant cow as donor for Ovum Pick-Up (OPU) derived oocyte aspiration and embryo production in Holstein heifers. Four non-pregnant and 2 pregnant Holstein heifers were used as donor and then carried out total 17 OPU session for 10 weeks (2 times per week). Recovered cumulus-oocyte-complexes (COCs) were classified into 4 grade by oocyte cytoplasm and cumulus cells and matured in vitro in TCM-199 supplemented with 10% FBS, 10 mg/ml FSH and 1 mg/ml estradiol in 5% $CO_2$ and over 99% humidity for 24 h. After 24 h co-incubation with post-thaw sperm, the presumed zygotes were cultured in CR1aa medium with 4 mg/ml BSA for 3 days and then changed CR1aa medium with 10% of FBS for another 3~4 days. The Mean number of aspirated follicles and collected oocytes in the early stage pregnant and non-pregnant heifers were $13.0{\pm}4.3$ and $10.6{\pm}3.9$, $5.4{\pm}3.4$ and $7.7{\pm}3.6$ per session, respectively. Rate of collected oocyte from aspirated follicles were 59.2% and 50.5%, respectively. The average number of good quality oocytes (Grade I and II) in the early stage pregnant and non-pregnant heifers was $3.7{\pm}2.7$ and $4.9{\pm}2.6$ (Mean${\pm}$SD). Cleavage and blastocyst developmental rates in Grade I and II were 22.2% and 25.5%, and then $1.7{\pm}0.9$ and $1.4{\pm}1.1$ blastocyst per session, respectively. In conclusion, OPU technology can be used in early stage pregnant and non-pregnant heifers without any problem and so applied OPU derived embryo production to maximize the ability of genetically valuable females.

A Study on the Characteristics of Dietary Behaviors and Food Intake Patterns of University Student according to the Obesity Index (대학생의 비만도에 따른 식생활 특성 및 식이섭취 양상에 관한 연구)

  • Oh Se-In;Lee Mee-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • v.19 no.1
    • /
    • pp.79-90
    • /
    • 2006
  • This study was performed to investigate the dietary behaviors and food intake patterns of university students according to the obesity index(OI). The subjects were 349 students(107 males and 242 females) who were assigned to one of the following groups based on the percentage of ideal body weight: underweight(OI< 90%), normal ($90%{\leq}Ol<10%$) and overweight($OI{\geq}110%$). The dietary behaviors and food intake patterns were evaluated by questionnaires and 24 hour recall method. The results were summarized as follows. The rates of underweight, normal, and overweight students were 33.8%, 61.0%, and 5.2% respectively. The ratios of underweight was higher than overweight, especially in case of female. The 60.46% of subjects responded that they had an irregular eating habits, especially in overweight group(72.22%). The 52.44% of subjects showed skipping mealtime more than one time per day. The overweight group had a tendency to overeat themselves than other groups. The normal group had less unbalanced dietary pattern than the other groups(p<0.0019). Most subjects had a snack(96.27%). The percentage of those who drank and smoked were 86.74% and 19.54%, respectively. The smoking value was significantly higher in the overweight group(p<0.0009). The food consumption frequency by food groups was not different among the groups except instant and fast food. More than 50% subjects consumed fish, legumes & its products, and vegetables everyday. There was significantly less rate of the instant and fast food consumption frequency in the normal group(p<0.0177). The 3/4 subjects that showed the lower consumed level in RDA(< 75%) were under-nutritional state in the Fe and Ca. In case of Ca, there was a higher NAR value in the overweight group(p<0.0257) significantly, and Fe, protein, vitamin $B_1$, vitamin $B_2$, and niacin showed similar tendencies. The INQ of Fe was significantly higher in the overweight group than other groups(p<0.0335).

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF