An improved Loop Shaping Approach of QFT using Genetic Algorithm and a Design of Steam Generator Water Level Control System in Nuclear Power Station (유전 알고리듬을 이용한 개선된 QFT의 루프 형성법 및 원전 증기발생기 수위제어계의 설계)

  • 김주식;김민환;유정웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.106-113
    • /
    • 1998
  • The steam generator waste level control system in a nuclear power station has difficulty in its mathematical modeling and theoretical application in both a transient and steady state operation. Therefore, the stability problem of the conventional control methods brings many researches interests to the various methods of a system design in recent years. In this study, an improved loop shaping approach is proposed by applying the genetic algorithm to QFT (Quantitative Feedback Theory) in designing a control system in order to the performance of the system. And the effects of the proposed methods are shown by the simulation results.

  • PDF

A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System (HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구)

  • Kim Chan-Ki;Han Byoung-Sung;Park Jong-Kwang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.457-467
    • /
    • 2005
  • This paper deals with the new frequency controller of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency controller after the removing of the present synchronous compensators. The simulation methods are the mix of PSCAD/EMTDC and PSS/E, the main system studies are done for the transient state analysis using PSCAD/EMTDC. The study cases are completed involving 3 phase, single phase trip and load tripping events and study plots presented. In conclusion, the new frequency measurement from the AC network gives effective frequency control and dynamic performance.

Development of a Wind Turbine Simulator based on RTDS and MG set (RTDS와 MG set을 이용한 풍력 터빈 시뮬레이터 개발)

  • Jeon, Jin-Hong;Cho, Chang-Hee;Kim, Seul-Ki;Ahn, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.515-516
    • /
    • 2006
  • 본 논문은 풍속이 변화하는 상황에서 풍력 발전 시스템의 동작을 실시간으로 모의할 수 있는 시뮬레이터의 구성과 실험 결과를 제시한다. 본 논문에서 제시하고자하는 풍력 발전 시스템 시뮬레이터는 실시간 시뮬레이터인 RTDS(Real Time Digital Simulator)와 11kW의 AC 서보 시스템을 포함하는 전동기-발전기 실험 장치(MG set, Motor-Generator Set)로 구현되었다. RTDS는 풍속 모델과 블레이드, 터빈, 발전기를 포함하는 풍력발전 시스템 모델을 실시간으로 모의하며 MG-set은 실시간으로 모의된 풍력 발전 시스템의 물리적 상태를 구현한다. 풍력 발전 시스템 모델의 동작점 궤적과 최대출력점추종(Maximum Power Point Tracking)제어에 의한 풍력 발전 시스템 시뮬레이터의 운전 결과의 제시를 통해 시뮬레이터의 유용성을 검증하였다. 본 논문에서 제시된 시뮬레이터는 상용 실시간 시뮬레이터를 이용하여 간단한 소프트웨어의 수정을 통해 다양한 모델의 풍력 반전 시스템을 모의할 수 있으며 다양한 실험 조건에서 과도상태 및 정상상태 특성 실험이 가능하므로 풍력 발전 시스템의 발전기 특성 평가, 전력 변환 장치의 성능 시험 등에 활용이 가능하다.

  • PDF

Robut DC Servo Motor Position Control System based on Acceleration Control (가속도제어에 근거한 강인한 직류서보전동기 위치제어계)

  • 박태건;이기상
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.5 no.4
    • /
    • pp.101-110
    • /
    • 1995
  • In this paper, a DC servo motor position control system based on acceleration control is proposed. The proposed control system consists of an acceleration controller and an auto-tuqing fuzzy PID controller. The auto-tuning fuzzy PID controller provides corrections for an acceleration reference to remove the effect of parametric uncertainties. And it comprises of the expert system which performs the automatic tuning of the PID controller parameters and the conventional PID controller. Expermental results demonstrate strate thi~tth e proposed overall control system has robust properties and good control performances with regard to unmeasurable disturbances and parameter variations. Therefore, the proposed control scheme enhances the applicability of an acceleration control approach and especially performs accurate position control under such an operating environment that model uncertainties exist and/or load, etc. change significantly.

  • PDF

A Fuzzy Controller for the Steam Generator Water Level Control and Its Practical Self-Tuning Based on Performance (증기발생기 수위제어를 위한 퍼지제어기 구현 및 제어성능지수를 이용한 제어기 의 Self-Tuning)

  • Na, Nan-Ju;Bien, Zeun-Gnam
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.317-326
    • /
    • 1995
  • The oater level control system of the steam generator in a pressurized water reactor and its control Problems are analysed. In this work a stable control strategy Particularly during low Power operation based on the fuzzy control method is studied. The control strategy employs substitutional information using the bypass valve opening instead of incorrectly measured signal at the low How rate as the fuzzy variable of the flow rate during low power operation, and includes the flexible scale adjusting method for fast response at a large transient. A self-tuning algorithm based on the control performance and the descent method is also suggested for tuning the membership function scale. It gives a practical way to tune the controller under real operation. Simulation was carried out on the Compact Nuclear Simulator set up at Korea Atomic Energy Research Institute and its result showed the good performance of the controller and effectiveness of its tuning.

  • PDF

Removal Characteristics of Toluene in Biofilters Packed with Reticulated-PU-Foams of Different Porosities (서로 다른 공극률의 망상형 폴리우레탄들이 충전된 바이오필터에서 톨루엔 제거 특성)

  • 명성운;남윤수;이용우;최호석
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.448-454
    • /
    • 2003
  • We studied on the removal of toluene vapors in a lab-scale biofilter. There are three biofilters packed with reticulated polyurethane foams of different porosities of 15, 25, 45 PPI (Pore Per Inch) as media. A toluene-degrading strain (Pseudomonas Putida KCCM 11348, ATCC 12633) was naturally immobilized on the filter media by circulating the culture media. Three biofilters were operated under different sets of continuous experiments, varying both the design and operation parameters such as the inlet toluene concentration and the flow rate. Maximum elimination capacity of 115.5g/㎥hr of biofilter packed with foams of 25 PPI was obtained for toluene degradation. The effect of operating conditions such as flow rate, inlet toluene concentration and porosity on the performance of the biofilter was investigated.

Numerical Analysis of the Prediction of Zincate Concentration at a Zinc Electrode with Electrolyte Flow Conditions in a Zinc Air Fuel Cell (전해질 유동 조건에 따른 아연공기전지 아연극 표면의 Zincate 이온 농도 예측을 위한 수치해석적 연구)

  • Kim, Jung-Yun;Lee, Ho-Il;Oh, Tae-Young;Park, Sang-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.231-238
    • /
    • 2011
  • In this work, the numerical analysis for the zincate behavior at a zinc electrode with an electrolyte flow was carried out for a ZAFC. The Nernst-Planck equation with a boundary condition of Butler-Volmer type was adopted to describe electrochemical effects of mass transfer, migration, kinetics of electrode. The Navier-Stokes equation, coupling to the Nernst-Planck equation, is also applied to describe the internal electrolyte flow fields. The validity of the numerical model is proved through the comparative analysis between numerical and experimental results. The concentration of zincate and the current density were also investigated at a zinc anode according to various electrolyte velocities. We have found the concentration of zincate decreased and the current density increased with an increase in the electrolyte velocity.

The Effect of Coagulant on Filtration Performance in Submerged MBR System (침지형 MBR 공정에서 응집제가 여과성능에 미치는 영향)

  • Kim Kwan-Yeop;Kim Ji-Hoon;Kim Young-Hoon;Kim Hyung-Soo
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.182-187
    • /
    • 2006
  • The purpose of this study was to investigate effect of coagulation on filtration performance of membrane in submerged MBR system and influence of continuous aeration to reduce fouling of membrane surface on coagulated floc. For this purpose, aeration tank sludge of MBR system was compared with jar-test sludge. The experimental results were analysed in terms of floc size and SRF (Specific resistance of Filtration). The more alum was added, the more content of floc below $10{\mu}m$ reduced and SRF decreased. But compared with jar-test results, it was found that effect of coagulation on MBR floc was reduced. Operation time of membrane in alum added MBR was longer than that in control MBR. But operation time was not proportional to alum dose. It was thought that the result was reason that floc below $10{\mu}m$ was not reduced sufficiently by shear force of continuous aeration. Moreover it was founded that if alum is added more than proper dose, it brings filtration resistance to increase.

Design of the Feed Forward Controller in Digital Method to Improve Transient Characteristics for Dynamic Voltage Restorers (동적전압보상기의 과도특성을 개선하기 위한 디지털방식의 전향제어기 설계)

  • 김효성;이상준;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.275-284
    • /
    • 2004
  • This paper discusses how to control the compensation voltages in dynamic voltage restorers (DVR). On analyzing the power circuit of a DVR system, control limitations and control targets are presented for the voltage compensation in DVRs. Based on the preceded power stage analysis, a novel controller for the compensation voltages of DVRs is proposed by a feed forward control scheme. This paper discusses also the time delay problems in the control system of DVRs. Digitally controlled DVR systems normally have control delay at amount of one sampling time of the control system and a half of the switching period of the DVR inverter. The control delay in digital controllers increases the dimension of the system transfer function one degree higher, which makes the control system more complicate and more unstable. This paper proposes a guide line to design the control gain, appropriate output filter parameters and inverter switching frequency for DVRs with digital controllers. Proposed theory is verified by an experimental DVR system with a full digital controller.

Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method (직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법)

  • 김진선;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.213-221
    • /
    • 2004
  • In recent years, since more and more diode rectifiers with smoothing dc capacitor are used in electronic equipments, household appliances and ac drives, harmonics generated by these loads have become a major issue. In addition, 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. This systems show excessive currents in the neutral. These neutral currents are fundamentally third harmonic, and their presence is tied to wiring failure, elevating of neutral potentials, transformer overheating, etc. In response to the concerns, this paper proposes a series active power filter scheme based on direct compensating voltage extraction method and the advantage of this control algorithm is direct extraction of compensation voltage reference without multiplying gain. Therefore, the calculation of the compensation voltage reference will becom much simpler than other control algorithm. To verify the effectiveness of the proposed algorithm, a prototype active power filter is built and some experiments are carried out.