• Title/Summary/Keyword: 공학분석

Search Result 25,814, Processing Time 0.059 seconds

Hydrogeochemistry and Origin of $CO_2$ and Noble Gases in the Dalki Carbonate Waters of the Chungsong Area (청송 달기탄산약수의 수리지화학과 탄산 및 영족기체 기원)

  • Jeong, Chan-Ho;Kim, Kyu-Han;Nagao, Keisuke
    • The Journal of Engineering Geology
    • /
    • v.22 no.1
    • /
    • pp.123-134
    • /
    • 2012
  • Hydrochemical analyses, carbon isotopic (${\delta}^{13}C_{DIC}$) analyses, and noble gas isotopic ($^3He/^4He$ and $^4He/^{20}Ne$) analyses of the Dalki carbonate waters in the Chungsong area were carried out to elucidate their hydrochemical composition and to determine the source of $CO_2$ gas and noble gases. The carbonate waters have a pH of between 5.93 and 6.33, and an electrical conductivity 1950 to $3030{\mu}S/cm$. The chemical composition of all carbonate waters was Ca(Mg)-$HCO_3$, with a high Na content. The contents of Fe, Mn, and As in some carbonate waters exceed the limit stipulated for drinking water. The concentrations of major ions are slightly higher than those reported previously. The ${\delta}^{13}C_{DIC}$ values range from -6.70‰ to -4.47‰, indicating that the carbon originated from a deep-seated source. The $^3He/^4He$ and $^4He/^{20}Ne$ ratios vary from $7.67{\times}10^{-6}$ to $8.38{\times}10^{-6}$ and from 21.32 to 725.7, respectively. On the $^3He/^4He$ versus $^4He/^{20}Ne$ diagram, the noble gas isotope ratios plot in the field of a deep-seated source, such as mantle or magma. We therefore conclude that $CO_2$ gas and noble gas in the Dalki carbonate waters originated from a deep-seated source, rather than an inorganic $CO_2$ origin as suggested in a previous study.

Effects of Well Parameters Analysis Techniques on Evaluation of Well Efficiency in Step-Drawdown Test (단계양수시험 해석시 우물상수 산정 방법이 우물효율에 미치는 영향)

  • Chung, Sang-Yong;Kim, Byung-Woo;Kim, Gyoo-Bum;Kweon, Hae-Woo
    • The Journal of Engineering Geology
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 2009
  • Step-drawdown tests were conducted at four pumping Wells, two in porous media and two in fractured rocks, respectively. In general, P = 2.0 suggested by Jacob (1947) is applied to porous media and fractured rocks in terms of drawdowns of step-drawdown test. In an attempt to review problems of linear model (Jacob's graphic method) in interpreting the step-draw down test, the outcomes of well parameters (aquifer loss coefficient (B), well loss coefficient (C) and well loss exponent (P)) calculated from linear and nonlinear model (Labadie and Helweg's least-squares method) were compared and analyzed. The values of C and P calculated from linear and nonlinear models differed according to permeability of aquifer and the conditions of pumping well. The value C obtained from nonlinear models in porous media and fractured rocks is about $10^0{\sim}10^{-2}$ and $10^{-3}{\sim}10^{-6}$ times lower than in their linear models, respectively. The value P of porous media obtained from nonlinear model ranged from 2.123 to 2.775, while it ranged from 3.459 to 5.635 for fractured rocks. In case of nonlinear model, well loss highly depends on the value P. At this time, well efficiencies calculated from linear and nonlinear models were $1.56{\sim}14.89%$ for porous media and $8.73{\sim}24.71%$ for fractured rocks, showing a significant error according to chosen models. In nonlinear model, it was found that the regression analysis using the least squares method was very useful to interpret step-drawdown test in all aquifer.

A Study on the Stiffness of CBA(Corner Block with Anchor Bolt) Joint in Knockdown Type Table Furniture (조립식(組立式) 탁자(卓子)의 CBA접합부(接合部) 강성(剛性)에 관(關)한 연구(硏究))

  • Chung, Woo-Yang;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.34-64
    • /
    • 1989
  • Corner block with anchor bolt(CBA) joint method used in knock-down type table furniture manufacturing can reduce the packing and transporting cost. Unfortunately. it also has the disastrous defect to be loosend and unstable during the service life mainly due to fatigue and creep(repeated and prolonged loading). So 22 joint groups constructed were tested to evaluate the effect of some design factors related to the size of side rail(apron). block attachment to side rail. and the number of anchor bolt as well as the effect of the type of corner block(mitered type vs. rectangular type) Usable strength from the stiffness coefficients of each joint group were analysed with SPSS /PC+ and described as the criteria of CBA joint construction. The conclusions were as follows: The height of side rail(50, 75 and 100 mm) and the addition of polyvinyl acetate(PVAc) emulsion in the corner block attactment to side rail had the effect on raising the usable strength of CBA joint with remarkable high significance. And the effect of 2 - anchor bolts was also superior to that of 1 - bolt significantly. However. the thickness of side rail(22 mm vs. 25 mm) had no effect on the strengthening the table joint rigidity. Mitered type corner block joint appeared to he recommendable for CBA jointed table construction rather than the rectangular type one regardless of the method of block attachment to side rail. The best result identified from Duncan's multiple comparison was in the construction with 25 mm thick and 100 mm height of side rail fastened using 2 - anchor bolts in mitered type corner block. But it would be reasonable to use 22 mm thick & 75 mm high side rail and mitered corner block with PVAc emulsion & 2 bolts considering the productivity and production cost down in the MDF furniture manufacturing industries.

  • PDF

병원정보시스템 품질 항목에 대한 제안

  • Park, Chan-Seok;Go, Seok-Ha
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2007.05a
    • /
    • pp.300-320
    • /
    • 2007
  • 정보기술의 발달과 함께 소프트웨어 제품은 모든 산업에 필수요소가 되었고, 품질과 평가에 대한 관심도 점차 증가되고 있다. 하지만 일부 산업에서는 소프트웨어 품질 평가에 대한 사용자들의 만병 통치적 기대, 품질 표준의 부족, 측정을 위한 양질의 데이터 부족, 소프트웨어 분석과 디자인에 대한 공학적 한계로 소프트웨어 품질 평가에 대해 많은 문제점이 지적되고 있다. 국내에서도 의료산업 관련 정보시스템의 오류 및 사용자들의 운영 미숙은 매년 많은 금액의 사회적 비용을 증가시켰고, 병원정보시스템의 품질에 대한 관심을 초래하였다. 특히, 산업적 특성이 강한 병원정보시스템은 성공적 구축을 위해 사용자 중심의 소프트웨어 디자인과 다양한 전문가들의 지식 통합이 필요하며, 정보시스템 품질 측정으로 연구자들과 개발자들의 시스템 설계 혼란을 감소시키는 방법론이 필요하다는 연구들이 등장하고 있다. 대부분의 병원정보시스템이 단편적인 업무처리 위주로 개발 운영되고 있고, 장기적 경영전략이나 임상연구를 위한 분석적 정보처리 기능들은 결여되어 있다. 또한 소프트웨어 재설계나 추가적 개발 에 활용될 수 있는 객관적 품질 기준이 부족하고, 사용자들의 요구사항에 대해 소프트웨어 설계에 있어서 효율적으로 반영되지 못하고 있다. 이에 본 연구는 최근 발표된 병원정보시스템 품질 평가에 대한 연구 경향을 종합하고, 품질 평가에 대 해 효율적으로 활용되고 있는 사용성(Usability)을 기준으로 병원산업의 특수성을 포함한 품질 평가 방법과 품질척도를 제안하고자 한다. 국제표준기구(ISO:International Standards Organization)에서는 품질 특성을 기능성, 신뢰성, 사용성, 효율성, 유지 보수성과 이식성의 특성을 제시하고 있다. 특히 Folmer & Bosch(2004)가 정리한 ISO9126에서는 품질의 특성을 배움의 용이성, 운영의 용이성, 이해성과 매력성으로 분류하였고, ISO9241-11는 효과성, 효율성과 만족성으로 분류하였다. 또한 Shackel(1991)은 배움의 용이성(배움과 시간, 기억력), 효과성(오류, 직무시간), 유연성과 마음가짐으로 분류하고 있다(Shackel, 1991). Nielsen(1997)은 배움의 용이성, 기억의 용이성, 오류, 효율성, 만족성으로 분류하고 있고(Nielsen, 1997), Shneiderman(1998)는 효과성(직무시간, 배움의 시간), 효율성(기억의 지속시간, 오류), 만족도를 품질의 특성으로 분류하였다. 이와 같은 소프트웨어의 품질은 소프트웨어 계획, 개발, 성장과 쇠퇴의 모든 과정에 적용되며, 환경적 변화에 따라 사용자들의 정보욕구를 적절하게 반영하여 만족도를 높이 는 것이라고 요약할 수 있다. 그러나 현재까지 소프트웨어 품질 평가에 대한 연구들 은 보편적인 평가 항목들을 대상으로 측정하여 일반적인 품질기준을 제시하고 있고, 유사한 측정 내용들이 중복되어 있다. 이러한 경향은 산업별 특수성이 강한 소프트웨어에 대해서는 정확한 품질측정이 어려웠고, 품질측정에 대한 신뢰성을 떨어뜨리는 계기가 되었다. 이러한 한계를 극복하고자 나타난 방법론이 최종사용자들의 요구사항을 얼마나 적절하게 시스템에 반영했는지에 대한 사용성(Usability) 측정이다. 사용성에 대한 정의는 사용자들이 실질적으로 일하는 장소에서 직접 사용자들의 시스템 운용실태를 파악하여 문제점을 개선하는 것으로 요약할 수 있다. ISO9124-11에서는 사용성을 "어떤 제품이 구체적인 사용자들에 의해 구체적인 목적을 달성하기 위한 구체적인 사용의 맥락에서 효율성, 효과성을 만족함으로 사용될 수 있는 정도"로 정의하고 있다. 지난 10년간 병원정보시스템 평가에 대한 문헌들을 고찰한 결과 품질 측정의 효과는 정보화에 대한 동기유발과 의료품질을 높이는 게기가 되었으며, 질병에 대한 예방효과도 높은 것으로 조사되었다. 그러나 평가에 대한 인식의 문제, 평가 방법의 신뢰성 부족, 평가 지침과 부분적 평가에 따른 인증의 어려움 평가 결과에 대한 확산과 단편적 연구의 한계 등으로 연구결과에 대한 신뢰도와 활용도는 낮은 것으로 조사되었고, HIS에 대한 연구 빈도와 범위 가 매우 미약하였다. 특히, 품질속성은 같은 용어이지만 연구자에 따라 전혀 다른 측정 내용을 제시하고 있어 효율적인 품질 지표를 제시하는데 많은 혼란을 초래하고 있다. 이러한 품질 평가의 경향은 시스템 설계 및 개발자들에게 필요한 사용자들의 구체적이고 독특한 욕구나 병원정보시스템 환경의 특수성 파악에 한계를 보였으며, 평가 범위도 부분적으로 이루어져 전사적 시스템 설계 및 개발에 중요한 자료를 제공하지 못하고 있다. 이러한 문제점과 한계를 극복하고자 ISO와 같은 품질 표준 속성과 컨텍스트(Context)를 중심으로 사용자에 의한 평가 척도의 설정은 구체적이고 실용적이며 신뢰성 있는 평가 방법이 될 것이다.

  • PDF

A Graph Layout Algorithm for Scale-free Network (척도 없는 네트워크를 위한 그래프 레이아웃 알고리즘)

  • Cho, Yong-Man;Kang, Tae-Won
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.5_6
    • /
    • pp.202-213
    • /
    • 2007
  • A network is an important model widely used in natural and social science as well as engineering. To analyze these networks easily it is necessary that we should layout the features of networks visually. These Graph-Layout researches have been performed recently according to the development of the computer technology. Among them, the Scale-free Network that stands out in these days is widely used in analyzing and understanding the complicated situations in various fields. The Scale-free Network is featured in two points. The first, the number of link(Degree) shows the Power-function distribution. The second, the network has the hub that has multiple links. Consequently, it is important for us to represent the hub visually in Scale-free Network but the existing Graph-layout algorithms only represent clusters for the present. Therefor in this thesis we suggest Graph-layout algorithm that effectively presents the Scale-free network. The Hubity(hub+ity) repulsive force between hubs in suggested algorithm in this thesis is in inverse proportion to the distance, and if the degree of hubs increases in a times the Hubity repulsive force between hubs is ${\alpha}^{\gamma}$ times (${\gamma}$??is a connection line index). Also, if the algorithm has the counter that controls the force in proportion to the total node number and the total link number, The Hubity repulsive force is independent of the scale of a network. The proposed algorithm is compared with Graph-layout algorithm through an experiment. The experimental process is as follows: First of all, make out the hub that exists in the network or not. Check out the connection line index to recognize the existence of hub, and then if the value of connection line index is between 2 and 3, then conclude the Scale-free network that has a hub. And then use the suggested algorithm. In result, We validated that the proposed Graph-layout algorithm showed the Scale-free network more effectively than the existing cluster-centered algorithms[Noack, etc.].

A Survey on the Hazardous Substances in Agricultural Products of Baggage by Incheon Port (인천항으로 반입되는 휴대농산물에 대한 유해물질 조사)

  • Kim, Ji-Hyeung;Cho, Nam-Gue;Lee, Gue-Sung;Joo, Gwang-Sig;Lee, Han-Jung;Hwang, Eui-Hwa;Go, Jong-Myoung;Kim, Yong-Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.1-12
    • /
    • 2007
  • This study was investigated hazardous substances in agricultural products of baggage by Incheon Port from chinese. We tested 293 kinds of dried red pepper, cereal, sesame, bean, nut, herbal medicine and sesame oil for pesticides residue, mold, tar color, sudan I, II, III, IV, aflatoxin, Pb, Cd, Hg, As and sulfur dioxide residues. Violated samples over standard limits by Korean Food and Drug Administration (KFDA) were 76 dried red pepper over the number of mold and 1 dried red pepper detected red 102 tar color and 1 dried red pepper over the number of mold and detected red 102 tar color simultaneously. And 2 rice, 1 sticky rice, 1 adlay and 1 millet were over lead. Violated herbal medicine were 2 Zizyphi Furctus and 2 Zingiberis Rhizoma over sulfur dioxide residue and 1 Zingiberis Rhizoma over sulfur dioxide residue and cadmium simultaneously. The contents of heavy metals in cereal were as follow; $Pb\;0.000{\sim}0.740mg/kg(0.191{\pm}0.209),\;Cd\;0.000{\sim}0.108mg/kg(0.007{\pm}0.020),\;Hg\;0.000{\sim}4.201mg/kg(0.162{\pm}0.319)$. The contents of heavy metals in herbal medicine were as follow; $Pb\;0.000{\sim}2.480mg/kg(1.130{\pm}0.730),\;Cd\;0.000{\sim}0.761mg/kg(0.044{\pm}0.122),\;Hg\;0.000{\sim}0.157mg/kg(0.022{\pm}0.033),\;As\;0.000{\sim}0.560mg/kg(0.040{\pm}0.082)$. Contents of $SO_2$ ranged $2.0{\sim}1459.4ppm(303.1{\pm}324.2)$.

Comparison of Cellular Anatomical, Physical and Mechanical Properties Between Dahurian Larch and Japanese Larch (잎갈나무와 일본잎갈나무의 해부학적, 물리·역학적 특성 비교)

  • Han, Yeonjung;Kim, Min-Ji;Lee, Hyun-Mi;Kang, Jin-Taek;Eom, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.525-534
    • /
    • 2017
  • The study aims to observe the cellular anatomical properties of Dahurian larch and Japanese larch for the species identification. In addition, other factors - the ring width, tracheid length, density, and strength - were compared and analyzed to clarify their physical and mechanical properties. To the end, three Dahurian larch trees and three Japanese larch trees by each diameter class were collected as specimens from Jeongseon-eup, Jeongseon-gun, Gangwon-do, to conduct a stem analysis. It was found that the average stand age, average diameter at breast height, and average tree height of three Dahurian larch trees and Japanese larch trees were 74 years and 51 years, 442 mm and 352 mm, and 26.1 m and 20.8 m, respectively. The cellular anatomical difference between Dahurian larch and Japanese larch can be usually found by spiral thickening, considering that it doesn't occur in Dahurian larch at all, while rarely does in the ray tracheids of Japanese larch. However, in this study, spiral thickening was not observed in the radial section of Japanese larch. The average annual growth diameters measured at 1.2 m-height of Dahurian larch and Japanese larch were 5.167 mm and 5.954 mm, respectively. Meanwhile, arboreal growth of Japanese larch was observed to be higher than that of Dahurian larch. In the physical properties test, it was measured that the latewood proportion and oven-dry density of Dahurian larch with low annual diameter growth were higher than those of Japanese larch, while the mechanical properties of Dahurian larch wood were measured 2-7% higher than those of Japanese larch wood. The data obtained from this study are expected to be used as the basic reference for species identification between Dahurian larch and Japanese larch by DNA analysis.

Determination of Phthalates Compounds in the Ambient Atmosphere (I) - Evaluation of a Measurement Method and its Application to a Field Study - (환경대기 중 프탈레이트 화합물의 농도 측정 (I) - 측정방법 평가와 현장 적용 -)

  • Hwang, Yoon-Jung;Park, Young-Hwa;Seo, Young-Kyo;Seo, Gwang-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.443-454
    • /
    • 2010
  • Phthalate compounds are widely used as plasticizers in polyvinyl chlororide (PVC) resins and other industrial consumer products, and some of them are known to be endocrine disruptors. In Korea, a number of studies have been carried out for the measurement of phthalates in consumer products and drinking water. However, no data are available for those compounds in the ambient air where the general public are routinely exposed. In this study, we evaluated sampling and analytical methods for the determination of phthalates in the ambient atmosphere. A wide range of phthalates compounds were included in the target analytes, which are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), and di-n-octyl phthalate (DOP). Most of samples were collected using a high volume sampler with a PUF/XAD-2 column/quartz fiber filter and then analyzed by GC/MS. Some of samples were simultaneously collected on XAD-2 using a low-volume sampler, together with high-volume samples. The analytical method applied in this study showed good repeatability and linearity. Quantitative detection limits were estimated from 0.60 to 17.84 ng/$m^3$ in air, depending on individual compounds. The field measurements were carried out at 3 sites located in Sihwa- Banwall industrial areas and a suburban area from January 2007 to November 2007. From the field experiments, DEHP, DMP and DBP appeared to be the most abundant compounds in the ambient air. It was also found that DMP, DEP and DBP were mainly distributed in the vapor phase, while BBP, DEHP and DOP were predominantly associated with the particulate phase. The concentrations of DEHP and DMP in the industrial areas ranged from 45.7 to 1,012.7 ng/$m^3$ and from 7.7 to 375.1 ng/$m^3$, respectively. Overall, the high-volume sampling method was demonstrated to be superior to the low-volume method for the determination of phthalates in the ambient atmosphere.

A Study on the Characteristics of Oil-water Separation in Non-point Source Control Facility by Coalescence Mechanism of Spiral Buoyant Media (나선형 부유 고분자 여재의 Coalescence 특성을 이용한 비점오염원 저감시설의 유수분리특성 연구)

  • Kang, Sung-Won;Kim, Seog-Ku;Kim, Young-Im;Yun, Sang-Leen;Kim, Soo-Hae;Kim, Mee-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.950-955
    • /
    • 2007
  • Non-point source control system which had been designed only for oil-water separation in the fields of oil refinery and garage was upgraded in this research for the removal of runoff pollutants in impervious urban area. Pollutants including oil from driveway and bridge were eliminated by two types of pathway in the system. One is the coalescence mechanism that the oil droplets in the runoff come into contact with each other in the spiral buoyant media surface and form larger coalesced droplets of oil that are carried upstream to the oil layer. The other is the precipitation that solids in runoff were settled by gravity in the system. In this research, coalescing characteristics of oil and water separation were investigated through image analyses, and efficiencies of the non-point source control system were evaluated using dust in driveway and waste engine oil. Media made of high density and high molecular weight polyethylene was indeterminate helical shape and had sleek surface by analysing SEM photographs and BET. Surface area and specific gravity of media which were measured directly were 1,428 $mm^2$ and 45.3 $kg/m^3$ respectively. From the image analyses of the oil droplets photographs which were taken by using microscope, it was proved clearly that the coalescence was the main pathway in the removal of oil from the runoff. Finally, the performances of the non-point source control system filled up with the media were suspended solid $86.6\sim95.2%$, $COD_{Cr}$, $87.3\sim95.4%$, n-Hexane extractable materials $71.8\sim94.8%$ respectively.

Dealumination of $NH_4Y$-Zeolite to Convert to the Hydrophobic Zeolite by High-Temperature Steam Treatment (소수성 제올라이트로의 변환을 위한 고온 수증기처리에 의한 $NH_4Y$-제올라이트의 탈알루미늄)

  • Kim, Jin-Young;Jeon, Dong-Hwan;Chung, Byung-Hwan;Mo, Se-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.420-430
    • /
    • 2005
  • This study was performed to change the hydrophilic $NH_4Y$-zeolite to the hydrophobic one for removal of VOCs by removing the $Al^{3+}$ in the zeolite-structure to increase the Si/Al ratio, for which the three pelleted $NH_4Y$-zeolite samples were contacted separately with the steam of $400^{\circ}C$, $500^{\circ}C$ and $600^{\circ}C$, respectively, in a stainless steel column for 4 hours. Then extraction of the ex-structure aluminum of the hydrolyzed zeolites with the nitric acids of 0.25, 0.50, 0.75, and 0.10 M at $90^{\circ}C$ in 500 mL-flasks, respectively, according to steam temperature were followed. XRD analysises of the dealuminated zeolites showed that the peaks of the zeolites that had been hydrolyzed with the steams of both $500^{\circ}C$ and $600^{\circ}C$ are distorted more with the increase of the concentration of nitric acid used for extraction of the ex-structure aluminums, however, those hydrolyzed with steam of $400^{\circ}C$ became amorphous phase when treated with the all nitric acids of four concentrations. Also the EDX analysises showed that the BET surface areas and TPVS of the zeolites that had been hydrolyzed with the steam of $600^{\circ}C$ were increased with the concentration of the nitric acid when the nitric acids of 0.25 M and 0.5 M had been used but decreased when the nitric acids of 0.75 M and 1.0 M had been used. These results led to the conclusion that both the $600^{\circ}C$ and $500^{\circ}C$-steam and the 0.5 M-nitric acid are appropriate to change the hydrophilic $NH_4Y$-zeolites to the hydrophobic one, which were proven by the measurement of the benzene and tolune-adsorbing capacities showing the same trend as the BET surface area and TPV The Si/Al ratios and water-adsorbing capacities of the dealuminated zeolites were increased and decreased, respectively, with the concentration of the nitric acids so that it showed that the hydrophobicity is increased.