Control Strategy for Cold Air Distribution System (저온송풍 공조시스템의 열원 제어)

  • Jeong, Seok-Kwon;Kim, Dong-Gyu;kim, Jong-Soo;Park, Jong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.480-483
    • /
    • 2008
  • The cold-air distribution system is expected as an efficient method to reduce energy consumption in the air-conditioning system. We introduced some control strategies for the system by summarizing some references in the view point of energy saving. Direct digital control is specially emphasized as an important control technique for the system. Some drawbacks which habe been conventionally mentioned to apply the cold-air distribution to real fields can be solved by using the technique. The control strategy which is introduced in here will be available to build control system for the air-conditioning based on the cold-air distribution for energy saving.

  • PDF

The Study of Relationship on Bio-Aerosol with Indoor Temperature Difference (실내 온도차에 따른 부유세균과의 상관관계 연구)

  • Park, Jin-Young;Kim, Sam-Uel;Yun, Jung-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.737-741
    • /
    • 2008
  • The indoor environment has an effect on heath of human in indoor room that they live largely. We will know Bio-Aerosol that causes illness, such as a flu, an asthma and an atopy etc. and see a relationship between Bio-Aerosol and temperature as an experiment in Air-Conditioned room. In the future, this data can use a basic data for an effect of Bio-Aerosol on indoor environment.

  • PDF

Economic Evaluation of Various Cooling Systems (냉방기기별 경제성 평가)

  • Kim, Young-Il;Cho, Keum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.214-219
    • /
    • 2008
  • In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of $1,200\;m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, equipment, construction, installation, electric facility, financial subsidy and tax cut are considered. Basic electricity, energy(electricity and gas), space charge, labor, insurance and repair are considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP. However, different outcome may result if different assumptions are made. This study is useful for performing an economic evaluation of various air-conditioning systems.

  • PDF

Analysis of Temperature and Humidity Distribution in a Dry Room (Dry Room내의 온.습도 분포 해석)

  • 이관수;임광옥;안강호;정영식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.524-531
    • /
    • 2001
  • The temperature and humidity distribution in a dry room are studied numerically by using standard$\kappa-\varepsilon$ turbulence model. In order to evaluate effective heat and moisture ventilation characteristics inside the room, the heat removal capacity and moisture exhaust efficiency are introduced. An effective ventilation control is analyzed by evaluating quantitatively temperature and humidity distributions. It was found that the mean absolute humidity inside the room was almost constant with approximately 0.1905g/kg air regardless of the models and the heat generation rates. This was believed that the moisture generation by workers was relatively small. 40% improvement of the critical decay time was achieved, through the modifications of design variables.

  • PDF

Experiments on Thermal Response of Space Conditioned by a Pl-Controlled VAV System (Pl제어 VAV시스템에 대한 공조공간의 열 응답특성 실험)

  • 문정우;박강순;김서영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.91-97
    • /
    • 2002
  • The present study concerns an experiment on the supply-air control in variable air volume (VAV) system with a Pl control logic. A thermal chamber with a Pl control logic is constructed to verify the previously suggested multi-zone model. The stratified thermal model is adopted in the control logic for a thermal chamber cooling test. The effects of taler- mal parameters and control parameters such as supply air temperature and Pl control factor are investigated by implementing the thermal chamber cooling test. The experimental results obtained show that the transient behavior of the air-conditioned space temperature are in good agreement with the simulation results of the stratified thermal model.

Numerical Analysis of Moisture Ventilation in the Dry Room (Dry room내 수분환기에 대한 수치적 연구)

  • 이관수;임광옥;정영식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.908-916
    • /
    • 2000
  • In this paper, the characteristics of moisture ventilation in the lithium ion battery manufacturing dry room are studied numerically using standard $k-\varepsilon$ turbulence model. Both the steady-state and the unsteady behaviors of moisture ventilation are analyzed by considering local and uniform moisture generation. In order to evaluate the characteristics of moisture ventilation, three scales of ventilation efficiency and characteristic ventilation time are presented from the numerical results. It was shown that moisture distribution was dependent strongly on the flow field. The characteristics of moisture ventilation were improved by 20% and 40% in terms of the 1st scale of ventilation efficiency (SVE1) and the 2nd scale of ventilation efficiency (SVE2), respectively, through the modifications of design variables such as the addition of inlets, outlets and partition. A significant improvement in the characteristic ventilation time and the moisture exhaust efficiency was also made by these modifications.

  • PDF

Thermodynamic Modeling of Finned Tube Evaporator for Dehumidification and Air Conditioning (제조공조용 핀-관형 증발기의 열성능 모델링)

  • 박병규;이태환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1020-1030
    • /
    • 2000
  • A crossflow finned tube evaporator has been investigated using tube-by-tube method. The refrigerant flows inside tubes while the air passes outside the finned tue. R134a for a refrigerant and wet air were used in this analysis. Three refrigerant circuitries, complex or simple, were compared. The effects of refrigerant circuitry and airside condensation on thermal performance such as heat transfer rate, enthalpy of refrigerant, temperature of refrigerant and air, pressure of refrigerant and average condensate layer thickness were investigated. It was found that this method could be applied to the analysis of finned tube evaporator for dehumidification and air conditioning.

  • PDF

Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings (고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구)

  • Cho, Jin-Kyun;Jeong, Cha-Su;Kim, Byung-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

A Study on the Heat Transfer Characteristics of Heating Unit in DPH HVAC (수송용 DPH HVAC 히팅유니트장치의 열유동 시뮤레이션평가연구)

  • Roh, Hong-Koo;Lim, Kyung-Bin;Noh, Jong-Ho;Lee, Young-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.605-610
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for room using 3-D numerical-analysis in order to design heating unit. The temperature comparison processes were done with various numerical conditions. In addition, the optimal conditions of heating unit design were proposed as inlet temperature, the inlet flow, heater power, and vessel size.

  • PDF

A Study on Performance of Air-condition Linked by Quick Disconnect Coupling (급속분리커플링으로 연결된 에어컨의 운전성능에 관한 실험적 연구)

  • Cho, Soo;Lee, Su-Yul;Sung, Uk-Joo;Park, Hee-Mun;Sim, Kyung-Jong;Kim, Woo-Seung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.551-556
    • /
    • 2008
  • This study analyzed operation characteristics of air-condition piping is made by quick disconnect coupling. Air-conditioning consists of central compressor 3HP capacity and R22 refrigerant. We experimented with two operation cycles of air-condition under the same environment; one is with quick disconnect coupling. The other is without quick disconnect coupling. As a result, we can observe whether the condensation temperature of former increased by about 3-5. Furthermore, COP decreased by about 10%.

  • PDF