• Title/Summary/Keyword: 공조설비

검색결과 587건 처리시간 0.249초

바닥급기 공조시스템(UFAC)을 적용한 작업공간의 실내환경 평가기법 개발연구 (A Study on the Design Prototype Development of Underfloor Air-Conditioning System(UFAC) for Improving Indoor Environment)

  • 정광섭;한화택
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.325-336
    • /
    • 2000
  • During the last decade, an increasing interest in Underfloor Air-Conditioning(UFAC) systems has emerged. The purpose of this paper is to evaluate comprehensively the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. In this paper, the physical measurements and the interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation(POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey.

  • PDF

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

WORK BARGE 선의 냉동.공조 SYSTEM (HVAC & Refrigeration System for Work Barge Vessel)

  • 남임우;정재천;김봉제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.583-590
    • /
    • 2008
  • 최근 작업자 숙소 및 이송용 외에 작업용으로 사용 가능한 Barge선의 일종인 Accommodation Work Barge 선의 건조량이 증가 추세인 바 현재 중국에서 건조 중인 해당 선박의 HVAC & Refrigeration system에 대하여 정리하였다. 본 시스템은 R404A Direct expansion 냉각방식 (직접팽창방식)이 적용되었으며 HVAC system 중 Air conditioning 부분에 대해서는 선박의 각 Deck 기준으로 Zoning 하여 개별적인 Air handling unit와 Condensing unit를 구성하였으며 (각 unit의 용량은 필요용량의 100%), 냉동 창고의 Refrigeration system은 해당 격실 (육고, 어고, 야채고)에 각각 Unit cooler를 설치하고, Condensing unit를 기계실에 설치하였다. 장비는 전체 용량 100%에 대하여 항시 운전하는 100% 용량의 장비와 비상시에 운전하는 100% 용량의 예비 장비로 구성된다. 냉동 창고에 인접한 Dry provision store는 냉동 창고와는 별개로 중앙 공조기로부터의 냉각 공기를 이용하여 Spot cooling하였다. 본 System의 구성에 대한 장점 및 단점은 아래와 같다. 1. Air conditioning system이 각 Zone에 대하여 구성되므로 각 Zone에 대하여 제어가 가능하다. 2. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 냉매 배관의 길이가 짧다. 3. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 실내의 Maintenance space 상에 여유가 없다.

  • PDF

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

모델실험 및 수치해석을 통한 페리미터존 에어배리어 공조방식웨 열성능 평가 (Evaluation of Thermal Performance for Air-Barrier Air-conditioning System in Perimeter Zone by Scale Model Experiment and Simulation)

  • 함흥돈;박병윤;손장열
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.947-955
    • /
    • 2005
  • For the purpose of evaluating the thermal performance for air-barrier air conditioning system in perimeter zone, two air-conditioning systems, conventional perimeter air-conditioning system and air-barrier system, are evaluated and compared by scale model experiment and simulation during cooling season. As a result, measurement shows that supply air velocity of 1 m/s in the upstream direction at perimeter is more effective. Air-barrier system could reduce the cooling energy by $10\sim20\%$ compared with conventional system. Numerical simulation was carried out considering solar effect for reliable result. This method has improved the accuracy of numerical simulation for the space affected by the solar radiation. Both measurement and simulation results show that supply air velocity of 1 m/s at perimeter is the most effective.

공조기용 인버터의 고효율화$\cdot$고성능화 기술

  • 대한전기협회
    • 전기저널
    • /
    • 통권315호
    • /
    • pp.74-79
    • /
    • 2003
  • 지구온난화 방지 등 환경보전을 목적으로 전기기기 및 설비의 전력소비를 저감시키기 위한 성에너지관련법이 일부에서 시행되어 각 방면에서 그에 대한 대책이 이루어지고 있다. 전기기기 중에서도 공조기는 일반가정의 소비전력에서 차지하고 있는 비율이 $24\%$로 상당히 큰 편이다 최근 공조기는 소비전력을 저감시키기 위해 기간부품의 효율 개선을 도모하여 왔으나, 이 효율 개선에는 전력소비가 큰 압축기(탑재)모터와 이것을 구동하는 인버터의 손실 저감도 반드시 필요하다. 또 효율개선 외에 공조기 운전시의 쾌적성 향상의 관점에서 저진동화 및 저소음화를 도모할 필요가 있어 구조명과 함께 인버터 제어면에서의 대책을 시행하여 왔다. 압축기 중에서도 성능개선이 두드러진 룸에어컨은 압축기에 고효율의 브러시레스 DC모터를 탑재하여 정현파구동방식을 이용한 인버터에 의해 고효율화를 실현하였다. 이 정현파구동방식은 독자적인 과(過)변조 PWM(Pulse-Width Modulation) 방식을 적용하여 효율 개선에 크게 기여하고 있다. 또 인버터는 압축기 특유의 맥동(脈動)부하에 기인하는 진동을 제어$\cdot$억제하여 저진동화를 실현하였다. 또한 패키지에어컨에서는 인버터 캐리어주파수에 기인하는 캐리어음(音)을 인버터제어로 억제하여 저소음화를 실현하였다. 본고에서는 공조기를 대상으로 특히 에너지 소비가 큰 압축기용 모터와 이것을 구동하는 인버터의 효율개선 기술과 저진동화 및 저소음화를 도모하기 위한 인버터 응용기술에 관하여 기술한다.

  • PDF

지하철 터널에서의 제연 (Smoke control in subway tunnels)

  • 차철현;김진국
    • 대한설비공학회지:설비저널
    • /
    • 제28권6호
    • /
    • pp.425-432
    • /
    • 1999
  • 국내의 경우 소방시설을 설치하여야 할 소방대상물과 그 설치 및 유지에 관한 기준은 소방법에서 정하고 있으며, 그 내용은 표 1과 같다. 지하철과 같은 궤도차량용 터널인 경우 소방법 상의 시설물에 대한 규정을 두고 있지 않다. 따라서 화재가 발생할 경우 피난, 구조 및 소화활동 등이 적절히 고려되지 않은 상태에서 팬의 제원과 성능이 결정되고 있다. 적절한 환기설비를 갖추지 않는 경우에 화재발생시 대형 인명사고가 발생할 가능성이 높다.

  • PDF