• 제목/요약/키워드: 공조설비부하

검색결과 42건 처리시간 0.023초

에너지 절약적 공조시스템 선정을 위한 기초적 연구 (A Study on the Energy Conservational HVAC System Design Strategies)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.58-63
    • /
    • 2007
  • Lots of needs are being paid for how to design HVAC system in large-scale buildings. Increasing awareness of energy use is main point of this research. HVAC systems' energy characteristics are not clearly identified and understood, so the optimal design of HVAC system is very important. The energy parameters of HVAC design that are system input energy, water/air moving equipments (pumps/fans) energy and outdoor air conditioning energy for IAQ are important. The purpose of this study is to provide the basic data for energy conservational HVAC design strategies.

  • PDF

엘리베이터 카 보조 전원을 위한 비접촉 전력전송 시스템 (Contactless power system for the elevator's car auxiliary power)

  • 임응규;노성찬;김수홍;김지민;김윤호;김은수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.49-51
    • /
    • 2007
  • 엘리베이터는 산업의 발전과 각종 건물의 고도화와 더불어 발전하여 왔다. 엘리베이터는 사람 또는 화물을 수송할 수 있는 카를 전동기를 통하여 견인하는 방식으로, 이동하는 카 내부에 전등 부하를 비롯한 공조시설, 제어설비 등 다양한 부하들이 존재한다. 지금까지의 엘리베이터는 전선을 사용하여 움직이는 카에 전원을 공급하는 방식을 사용함으로 부대설비가 복잡하여 지고 시공상에 어려움이 존재한다. 본 연구에서는 부대설비를 간소화하고 유지보수의 편리함을 제공하기 위하여 비접촉 전원장치를 이용한 이동하는 카에 전원을 공급하는 방식을 제안하고, 비접촉 전원장치에 사용되는 인버터와 변압기를 설계하여 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

빙축열을 이용한 저온공조시스템 운전 특성 연구 (Study on operation characteristics of the cold air distribution systems with an ice storage tank)

  • 염한길;박병규;고득용
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

공조기용 인버터의 고효율화$\cdot$고성능화 기술

  • 대한전기협회
    • 전기저널
    • /
    • 통권315호
    • /
    • pp.74-79
    • /
    • 2003
  • 지구온난화 방지 등 환경보전을 목적으로 전기기기 및 설비의 전력소비를 저감시키기 위한 성에너지관련법이 일부에서 시행되어 각 방면에서 그에 대한 대책이 이루어지고 있다. 전기기기 중에서도 공조기는 일반가정의 소비전력에서 차지하고 있는 비율이 $24\%$로 상당히 큰 편이다 최근 공조기는 소비전력을 저감시키기 위해 기간부품의 효율 개선을 도모하여 왔으나, 이 효율 개선에는 전력소비가 큰 압축기(탑재)모터와 이것을 구동하는 인버터의 손실 저감도 반드시 필요하다. 또 효율개선 외에 공조기 운전시의 쾌적성 향상의 관점에서 저진동화 및 저소음화를 도모할 필요가 있어 구조명과 함께 인버터 제어면에서의 대책을 시행하여 왔다. 압축기 중에서도 성능개선이 두드러진 룸에어컨은 압축기에 고효율의 브러시레스 DC모터를 탑재하여 정현파구동방식을 이용한 인버터에 의해 고효율화를 실현하였다. 이 정현파구동방식은 독자적인 과(過)변조 PWM(Pulse-Width Modulation) 방식을 적용하여 효율 개선에 크게 기여하고 있다. 또 인버터는 압축기 특유의 맥동(脈動)부하에 기인하는 진동을 제어$\cdot$억제하여 저진동화를 실현하였다. 또한 패키지에어컨에서는 인버터 캐리어주파수에 기인하는 캐리어음(音)을 인버터제어로 억제하여 저소음화를 실현하였다. 본고에서는 공조기를 대상으로 특히 에너지 소비가 큰 압축기용 모터와 이것을 구동하는 인버터의 효율개선 기술과 저진동화 및 저소음화를 도모하기 위한 인버터 응용기술에 관하여 기술한다.

  • PDF

사무용 건축물 공조설비 설계도서 분석 (Analysis of Office Building HVAC System Drawings)

  • 박종일;김세환;김동규
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.776-781
    • /
    • 2007
  • Optimized capacity of equipments are essential for energy saving and low cost construction and operation. So we must use proper design data for HVAC system design. We investigated for architectural data, equipment capacity, cooling and heating load design criteria of 52 office buildings. Following research results were obtained by carrying out each task. Office building effective area rate is 63%. The average building cooling load of South Korea is $140W/m^2$ and average heating loads in Seoul and Pusan area are $120{\sim}130W/m^2$ and $70{\sim}80W/m^2$. We also analysised HVAC design criteria. Person ratio in effective building area is $0.2person/m^2$, sensitive and latent heat loads of a person are 60W and 65W, light and equipment loads of office buildings are $25W/m^2$ and $20W/m^2$.

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

전력부하 평준화를 위한 축냉시스템 개발

  • 최병윤;유제인;윤재호
    • 전기의세계
    • /
    • 제44권6호
    • /
    • pp.19-26
    • /
    • 1995
  • 1992년 12월부터 일정규모 이상의 건물에 대한 절전설비의 설치 의무화가 시행되면서 국내에서의 빙축열시스템 보급이 크게 확대될 것으로 전망된다. 그러나 현재 국내에 도입되어 설치되는 빙축열시스템은 외국으로부터의 기술도입이나 완제품으로 수입되는 제품들이 대부분이며 빙축열시스템 사업에 참여하고자 하는 기업들 역시 수입을 검토하고 있는 실정이다. 그러므로 열적성능이 뛰어나고 시스템의 효율적인 운용이 가능하며 경제적으로 우위에 있는 빙축열시스템을 국산화 개발하는 것은 매우 중요하리라 사료된다. 이러한 필요성에 의하여 본 연구원의 냉동공조연구팀은 포접화합물과 공융염을 이용한 두가지의 새로운 빙축열시스템을 개발하였으며, 열적 성능이 뛰어나 원활한 전력에너지 수급과 수입 대체 및 수출을 통한 기업의 국제 경쟁력 향상을 꾀할 수 있을 것으로 사료된다.

  • PDF

여름철 공조시스템의 최적 운전 제어 방식 (Optimal air-conditioning system operating control strategies in summer)

  • 허정호
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

복합 공간 구성 건물의 공조구역 운영 전략에 따른 에너지부하 특성 연구 (Study on the Operation Strategy of A Building with Multi-Complex Spaces)

  • 육인수;김민환;남현진;김동호;설동문;이건태;김진호;김재민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.108-113
    • /
    • 2009
  • Buildings with multi-complex spaces designed for architectural values and functional requirements give rise to technical challenges in terms of energy efficiency and thermal comfort. Since spaces in such buildings are connected with openings with geometrical complexity, it is hard to define zoning plan and to control heating/cooling loads effectively. This paper presents a case study on the evaluation of operation strategy for a building with multi-complex spaces using computer simulation. The modelling methodology and the results of the simulations are also described.