• Title/Summary/Keyword: 공용부

Search Result 137, Processing Time 0.029 seconds

Statistical Analysis of the Structure and Performance of Fire Doors for Evacuation Space and Common Areas in Apartment Housing (공동주택 대피공간·공용부 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.3
    • /
    • pp.239-249
    • /
    • 2022
  • Fire resistance performance and performance design of fire doors are becoming more important to prevent the spread of fire and support the rapid evacuation of apartment buildings. In this study, a database using 182 evacuation spaces and 308 common areas that passed the fire performance test was established, and fire door performance influencing factors were derived through an analysis of the structure(12 elements) of the fire door. As a result, the effects of fire-resisting filler density, adhesive, and foam gasket were confirmed for evacuation space, and the effects of fire-resisting filler, adhesive, and fire fins were confirmed for common areas. In the fire door fire resistance test, flames and cracks were analyzed as the most frequent failure factors.

A Study of Failure Analysis on the Communication Equipment of common-basestation in the Subway (지하철내 공용기지국 통신장비 장애 분석에 관한 연구)

  • 신지윤;박덕규
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.443-448
    • /
    • 2003
  • Ministry of Information and Communication(MIC) requires telecompanys to be base station sharing in order to prevent the duplicated investment and environmental destruction due to indiscreet constructions of a basestations for enlarging its own service area among telecompanys. This paper discussed the troubles of mobile communication services to be generated in common-basestation at the subway, such as factors of power obstacles, communication equipment and establishment obstacles. The content of this paper is helpful in organizing the basestation sharing of IMT-2000 and the 4th generation mobile system, and provides the basic of a higher quality service for common-service communication.

  • PDF

A Study on the Fatigue Crack at Welded Joint for Steel Plate Girder Railway Bridge (강철도 플레이트거더교 용접이음부 피로균열의 평가에 관한 연구)

  • Park, Jin-Eun;Kyung, Kab-Soo;Lee, Sung-Jin;Jo, Yun-Jae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.306-309
    • /
    • 2010
  • 강철도 플레이트거더교의 경우 일반적으로 레일의 폭보다 거더 사이의 폭이 넓기 때문에 거더에 편심이 작용하게 된다. 이러한 편심 영향으로 거더 내측 상부플랜지에 휨변형이 일어나게 되어, 상부플랜지와 수직보강재 용접이음부에 반복하중에 의한 피로균열이 발생되고 있는 것으로 보고되고 있다. 본 연구에서는 공용중인 강철도 플레이트거더교를 대상교량으로 하여 공용하중에 대한 구조해석을 실시하였다. 대상교량에 대한 현장계측을 기초로 구조모델링을 검증하였고, 검증된 구조모델링을 사용하여 열차하중 하에서의 상부플랜지와 수직보강재 용접연결부에서의 피로균열 보강방안에 대한 구조해석을 실시하였다. 또한 상부플랜지와 수직보강재 용접이음부 상세해석을 통하여 피로균열 발생위치를 확인하고 연결이음부의 적절한 보강방안을 제시하고자 한다.

  • PDF

The Flexural and Shear Behaviors of Steel-PSC Mixed Structural System with Front-Rear Plate Connection (전·후면판 공용방식 접합부를 갖는 강-PSC 혼합구조의 휨 및 전단거동)

  • Lho, Byeong-Cheol;Cho, Sung-Yong;Park, Hyun-Chul;Kim, Mun-Kyum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.201-212
    • /
    • 2007
  • This study presents experimental results of Steel-PSC mixed structural system having front-rear plate connection between Steel and Prestressed Concrete. Two kinds of Steel-PSC mixed structural system of 5.4m length were tested to evaluate flexural behaviors under four point loading, and 4 kinds of specimens with and without prestressing force at R & L type connection were tested to observe the shear behavior. Based on the test results of load-deflection curves and failure modes of specimens, it is found that the proposed L shape connection with front-rear plate connection between Steel and Prestressed Concrete has higher strength and stiffness. From the study, Steel-PSC mixed structural system with L shaped connection has a better structural performance in connection part.

Failure Analysis on the Equipment of PCS common-repeater at the Metropolitan Subway (수도권 지하철내 PCS 공용중계기 장비장애 분석)

  • 신지윤;박덕규
    • The Journal of the Korea Contents Association
    • /
    • v.3 no.2
    • /
    • pp.78-86
    • /
    • 2003
  • The Minisoy of Information and Communication(MIC) requires telecompanys to share base stations in order to prevent the duplicated investment and environmental destruction which would be caused by the indiscreet construction of basestations for enlarging their own service area among telecompanys. This paper discusses' the problems of mobile communication services that have been generated in common-repeater at the Metropolitan subway. These problem include factors of power obstacles, communication equipment and establishment obstacles. The content of this paper is helpful in organizing the basestation sharing of IMT-2000 and the 4th generation mobile system, and provides the basics of a higher quality service for common-service communication.

  • PDF

Development of Common PCS Base Station System (PCS 공용 기지국 시스템 개발)

  • 황선호;박준현;김훈석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.214-217
    • /
    • 2001
  • This paper presents an implementation methodology of common Rf- integrated PCS base station system which, is capable of providing PCS services for 3 PCS carriers concurrently and wireless system performance evaluation data is shown. We have built up a common PCS base station system using a commonization module, which is consisted of a multi-channel combiner, duplexer, LNA, power divider, feeder line, and a common set of antennas. It was shown that the performance of the system within the total 30MHz PCS frequency range is uniformly acceptable and measured signal quality and coverage are equivalent to that of the individual PCS base station. It is expected that PCS carriers are able to save a huge amount of installation and maintenance expenses by installing and sharing this base station system. This paper forms a groundwork for deploying efficient and economical IMT-2000 network.

  • PDF

Performance and Economic Analysis for Rut-resistance Pavement Considering Life Cycle Cost (LCC를 고려한 내유동포장의 공용성 및 경제성 분석에 관한 연구)

  • Do, Myungsik;Han, Daeseok;Yoo, Inkyoon;Lee, Soohyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.783-796
    • /
    • 2006
  • Rut-resistance pavement is adopted to prevent pavement from plastic deformation since 1998. The objective of this paper is to investigate performance and economic efficiency between rut-resistance pavement and conventional hot-mix asphalt(HMA) on national highway. The pavement deterioration models incorporated in HDM-4 have been calibrated and adapted to local road conditions based on observed pavement rut-depth data. Based on calibration result of HDM-4, the economic evaluation including road agency cost and user cost is performed for 34 road pavement sections. Furthermore, we presented optimal timing for maintenance and performance levels subject to different budget. We found that rut-resistance pavement is performing better than conventional hot-mix asphalt in most road sections. Furthermore, we confirmed that the application of HDM-4 is useful for pavement project planning and evaluation. More investigation is needed to enlarge the scope of the pavement data and to explore more deeply socio-environmental cost and delay cost.

RF Transceiver Design and Implementation for Common Data Link (공용 데이터링크 RF 송수신기 설계 및 구현)

  • Kim, Joo-Yeon
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.371-377
    • /
    • 2015
  • This paper is about the RF transceiver designed and implementation for common data link. The trasmitter is configured as a frequency up-converter, a power amplifier and a duplexer. The receiver is configured as a duplxer, a frequency down-converter and a low noise amplifier. The maximum transmission distance, the reception sensitivity is designed to meet the electrical and temperature characteristics and the like. Using a modeling and simulation in order to meet the requirements of the RF transceiver has been designed and implemented. Transmitting output power and Noise Figure has been measured with 38.58dBm and 5.5dB, respectively. All of the electrical and temperature specifications was meet. Was confirmed all of the requirement specification by electrical characteristics test and temperature characteristics test.

전기동향

  • Korea Electrical Manufacturers Association
    • 전기산업
    • /
    • v.7 no.1
    • /
    • pp.99-105
    • /
    • 1996
  • PDF