A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

A study on the air leakage performance improvement of duct coupling for temporary ventilation of long subsea tunnel (초장대 해저터널의 공사중 덕트 접속부의 누풍 성능 개선에 관한 연구)

  • Jo, Hyeong-Je;Min, Dea-Kee;Kim, Jong-Won;Lee, Ju-Kyung;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.319-333
    • /
    • 2017
  • The construction of long sub-sea tunnel does not provide the favorable condition for the installation of ventilation system to be used during construction due to the constrained construction space. For the ventilation system required during construction, the artificial island where ventilation shaft is located is constructed at some location along the sub-sea tunnel route, which requires a high construction cost. Therefore, it is intended, as much as possible technically, to minimize the construction of artificial island. However, this requires a longer distance between ventilation shafts, there-by causing increased air leakage at the ventilation duct connection points due to the higher fan pressure being required to deliver ventilation air. Previously the air leakage was studied as an important issue. In this study experiments were carried out to develop the improved duct connection method considering various conditions such as, tunnel length, etc. Additionally, its performance results with leakage rates are shown and compared to the "S" class leakage rate of SIA. As a result, the new duct coupling type of improved method is analyzed as applicable to such a 30 km long tunnel with the leakage rate of $1.46mm^2/m^2$, which is better performance than SIA leakage rates.

도로터널의 환기시스템

  • Jo, Hyeong-Je;Baek, Jong-Hun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.40 no.4
    • /
    • pp.11-17
    • /
    • 2011
  • 적정한 환기용량의 산정과 최적의 환기방식선정으로 공사비를 절감하고, 운영 중의 안전성도 확보하는 방안을 소개하고자 한다.

  • PDF

A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct (공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구)

  • Jo, Hyeong-Je;Jun, Kyu-Myung;Min, Dea-Kee;Kim, Jong-Won;Beak, Jong-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.145-160
    • /
    • 2018
  • Long subsea tunnel is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for tunnel ventilation. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. As a result, ventilation distance become longer and supply airflow becomes excessive due to air leakage, So, duct mounting for temporary ventilation is impossible or fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In previous study, we have found that air leakage is the key factor in solving these problems and experimental results show that the new connection method has a leakage rate of about $1.46mm^2/m^2$ (Jo et al., 2017). In this study, we present the experimental results of the measurement of the leakage rate of the prototype with the new connection method, and analyze experimentally the improvement of the leakage rate when applying the flexible cover inside the duct to improve the leakage performance of the existing connection method.

Evaluation on the Removel Effect of $PM_{10} and PM_{2.5}$ by Operating the Dust Collection Train and the Washing Train (집진열차 및 살수차운영에 의한 지하철역 미세먼지 농도 저감효과 분석)

  • 김민영;김동일;조기찬;이연수;하광태
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.421-424
    • /
    • 2003
  • 서울지하철은 총연장 286.9km에 1일 4226회의 운행회수 그리고 대중교통수단 중 총 34.1%의 최다 수송분담율을 담당하고 있다. 서울시의 도심교통문제 해결 방안으로 시민들에게 대중교통 이용을 적극적으로 권장하고 있으나, 지하철 역사의 환경문제는 답보 상태를 유지하고 있는 것이 현실이다. 지하철내의 먼지문제는 이미 심각한 사회문제로 대두된 지 오래이며 이를 개선하기 위하여 지하철공사와 도시철도공사에서는 환기시스템의 개선, 환기 및 공기정화시설의 설치 그리고 잦은 물청소실시 등을 시행하여 오고 있어 그간 상당한 효과를 이룬 것도 사실이다. (중략)

  • PDF

Analysis of Ventilation Impact in Multi-Family Residential Building Utilizing TOPSIS Method (다기준 의사결정방법을 이용한 공동주택 내 환기장치 종류별 효과분석)

  • Park, Kyung-Yong;Kim, Gil-Tae;Kim, Tae-Min;Ji, Won-Gil;Kwag, Byung-Chang
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.107-113
    • /
    • 2022
  • With increasing airtight building construction aimed at reducing energy consumption, indoor relative humidity is increasing which can lead to condensation and moisture damage in multi-family residential buildings. This has led to increased implementation of mechanical ventilation to control indoor moisture. However mechanical ventilation systems consume additional energy and generate noise. As this leads to occupant discomfort, it is necessary to select a ventilation system that addresses the energy and noise issues. This research measured the ventilation performance, energy consumption, and noise level of mechanical ventilation devices in multi-family residential buildings. TOPSIS, a multi-criteria decision making technique was used to determine appropriate ventilation strategies in addition to occupant ventilation system operation preference.

Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed (옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가)

  • Jo, Hyun-Joung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.334-342
    • /
    • 2022
  • The stringent air environment conservation act forced to build an indoor dome for coal storage. However, it causes some problems due to accumulation of fly ash and harmful substances inside. To solve this problem, this study analyzed the pattern of internal airflow and the amount of ventilation for an indoor coal yard. Overall, the airflow inside the indoor coal yard tended to move to the southwest facing the mountain. In addition, sea-breeze was blowing from the northern louver window facing the sea, where airflow was flowing in. The total flow rate flowing into the indoor coal yard was 918,691 m3/h, and the number of natural ventilation per hour was 0.6 times. Therefore, it is proposed to install a forced ventilation device at the location where internal air flow is concentrated.

Improvement of the Architectural Environment by Applying Photocatalyst Building Materials and Ventilation Systems (광촉매 건축자재와 환기시스템 적용에 따른 건축 환경 개선 방안)

  • Yong Woo Song;Seong Eun Kim;Se Hyeon Lim;Sung Jin Sim
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.103-110
    • /
    • 2023
  • People who spend most of their day indoors are continuously exposed to internally and externally generated indoor pollutants. According to a 2022 report from the World Health Organization (WHO), air pollution is the cause of more than 7 million deaths annually worldwide, emphasizing the seriousness of indoor air pollutants. Air pollutants include nitrogen oxides (NOx), formaldehyde (HCHO), and volatile organic compounds (VOCs), which have serious effects on the human body. Photocatalyst is a material that can remove these indoor air pollutants. Photocatalysts not only have the ability to remove dust precursors, but also have antibacterial, sterilizing, and deodorizing functions, making them effective in improving indoor air quality. This study suggests areas and methods in which photocatalysts can be applied to buildings. Fields of application include interior and exterior construction materials such as concrete, as well as organic paints and ventilation devices. If appropriate utilization plans are developed, it may be possible to improve the built environment through reduced indoor and outdoor pollutant levels.