• Title/Summary/Keyword: 공동의 안전성

Search Result 390, Processing Time 0.026 seconds

A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses (공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Lee, Doo Hee;Hwang, Hyun Soo;Kim, Hee Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.38-50
    • /
    • 2022
  • Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.

Developments of performance-based evaluation criteria of utility tunnel (성능중심의 공동구 평가 기준 개발)

  • Byun, Yo-Seph;Seong, Joo-Hyun;Cho, Gey-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.715-724
    • /
    • 2022
  • With the enforcement of the infrastructure management act, the importance of utility tunnels that jointly accommodate life-lines such as electricity, communication, water supply, and heating facilities has increased. The currently applied utility tunnel maintenance system is managed in an accident-preventive safety-based evaluation method. However, this evaluation method has limitations in effective maintenance. In this study, performance evaluation items were derived through the Delphi method to suggest a criterion for quantitatively evaluating the performance of utility tunnels, and the weights for each item were calculated through the Analytic Hierarchy Process (AHP) method. In the future, it is judged that a more reasonable performance evaluation standard of utility tunnel can be prepared if modifications and supplements are made through field application.

A Checklist and Manual Developed to Review Fire Safety Facilities' Compliance with Fire Safety Requirements for Apartment Buildings (공동주택 소방시설 적법성 검토를 위한 화재안전규정 체크리스트 및 매뉴얼 개발)

  • Jeong, Soo-jin;Park, Yoo-na;Kim, Jae-jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.94-102
    • /
    • 2018
  • Recently, there is a growing need to review compliance with legal requirements to ensure fire safety as the number of fires caused by noncompliant fire safety facilities in high-rise buildings has increased. While there are a large number of apartment buildings in Korea, there is a lack of review on fire safety facilities' compliance with fire safety requirements. The reason for this lack of review despite apartment buildings causing deaths due to their structural features in the event of a fire, lies in the misinterpretation of legal provisions as the Building Act and the Fire Services Act are mixed up; a final inspection when fire safety facilities are unnecessarily installed or missing could result in significant losses in terms of finances and time. Therefore, this study developed a checklist that makes it possible to review mixed-up legal requirements for fire safety facilities simultaneously, and examined the importance and current level of each item through IPA (Importance Performance Analysis). Based on these results, this study intends to develop a manual that considers its applicability to construction practices and contribute to reducing construction companies' fire safety inspection risks.

A numerical study on the characteristics of small underground cavities in the surrounding old water supply and sewer pipeline (노후 상하수관 주변지반의 소규모 지하공동 형상 특성을 고려한 수치해석에 관한 연구)

  • An, Joon-Sang;Kang, Kyung-Nam;Song, Ki-Il;Kim, Byung-Chan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.287-303
    • /
    • 2018
  • In recent years, the occurrence of ground subsidence phenomenon is frequent in Korea. The Korean government has enacted a special law on underground safety and the law will be enforced from January 1, 2018. Under this new law, underground excavation should be assessed for underground safety impacts. After excavation construction, periodic geophysical surveys should be conducted to investigate the occurrence of underground cavities. When underground cavities were discovered, the underground safety was assessed through numerical analysis. However, it is controversial because the method of numerical modeling the discovered underground cavity is due to be established. In this study, the effect of the depth of the underground cavity from the shape of the underground cavity to the underground cavity was studied using a continuum analysis program. In this study, a method to reflect the shape of the underground cavity to the numerical modeling is presented. The relationship between the shape and depth of the underground cavity, and the factor of safety calculated by the shear strength reduction method (SSR) is presented. The results of this study are expected to form the basic data on underground safety impact assessment.

Critical Essay on the Notice of the Price Adjustment of Generic Drugs (제네릭 의약품 약가 조정 고시에 대한 비판적 고찰)

  • Park, Jeong Yeon
    • The Korean Society of Law and Medicine
    • /
    • v.22 no.1
    • /
    • pp.91-124
    • /
    • 2021
  • In May 2019, the Ministry of Food and Drug Safety revised the "Pharmaceutical Determination and Adjustment Criteria" with the content of differentially calculating the price of generic drugs according to the registration of the drug substance and meeting the requirements for their own bioequivalence test. According to this revised rule, if their own bioequivalence test is not conducted, even the generic drugs that have already been approved would be lowered in price. I wondered whether this system was introduced with sufficient public legal considerations regarding its legislative purposes and means. Therefore, I reviewed the contents of the revised notice based on whether or not it is valid to determine and adjust the price of generic drugs in terms of the legitimacy of legislative purposes and the proportionality principle after introducing the history and background of the rule. First, I raised a question as to whether the purpose of preventing the overrun of generic drugs is indeed legitimate in terms of the legitimacy of the purpose. In order for the revised notice of "reduction of drug prices when the test requirements are not met," to meet the conformity principle, the premise that it is difficult to recognize safety and effectiveness through consignment (joint) bioequivalence test or that these tests are insufficient in safety and efficacy verification than their own test must be established. Nevertheless, it seems that suffficient review has not been carried out. In order to achieve the purpose of securing safety and effectiveness, the focus should be on 'reinforcement of the standards for bioequivalence test and the management of the bioequivalence test itself' rather than whether it is a their own test or a consignment (joint) test. Third, it is contrary to the necessity and substantiality principle that strict standards are uniformly applied to the products that can be considered to have been sufficiently verified for safety and effectiveness after a considerable period of time has passed after the product approval. In many cases, revised administrative legislations quickly enacted and amended in the state of lack of legal review or consensus, while the regulatory effects resulting from it are quite direct and specific to the regulated person. In this respect, I emphasized that the administrative legislative process also requires substantial review and prior control of the regulatory purposes and means, and that the participation of stakeholders in the legislative procedure is to be strengthened.

Analysis of Pillar Stability for Ground Vibration and Flyrock Impact in Underground Mining Blasting (발파진동 및 비산충격에 대한 광주 안정성 분석)

  • Park, Hyun-Sik;Kim, Ji-Soo;Ryu, Bok-Hyun;Kang, Choo-Won
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.9-20
    • /
    • 2012
  • These days, mining industry prefers underground development for large mining because of exhaustive minning resources and large drafts and mining cavities thanks to extensive distribution of heavy excavation machines. In a mining design, to control collapse of cavities and secure stability, design of cavities and pillars are considered as very important. Therefore, this study obtained a prediction equation of blasting vibration through instrumentation for underground cavities. And we obtained theoretical shock vibration imposed on pillar through fragmentation analysis and measurement of flyrock distance. To examine the influence of pillar in underground mining blasting, we carried a finite element analysis and compared the result with prediction equation of blasting vibration, and shock vibration of flyrock when a impact was imposed on pillar and theoretical shock vibration.

Analysis of Disaster for Common Utility Tunnel & Schemes of Establishing Construction criteria (공동구 재해사례와 건설기준 제정방안)

  • Yoo, Jai-Sung;Lim, Jong-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1236-1245
    • /
    • 2009
  • 공동구는 도시생활을 영위하는 데 필요한 전기, 가스, 상 하수도, 전화, 통신 등의 공공시설물을 지하매설물 형태로 설치하여 시민들의 일상생활 및 사회 경제활동의 편의성을 제공하고 안전하고 안락한 도시환경을 유지시키며, 효율적인 도시운영이 가능케 하는 공공시설물이다. 그러나, 최근 들어 여의도 공동구 화재(2000년), 여수 공동구 침수(2003년), 구리시 전력구 화재(2006)등과 같이 공동구 및 전력구에서의 화재, 혹은 침수 등에 의해 재해가 발생하여 이로 인한 국가적 경제적, 사회적 손실이 늘어가고 있다. 하지만 국내에서는 공동구내 설비를 화재 및 재해로부터 보호하기 위한 법적 장치가 미비한 실정이며, 현재 운영되고 있는 공동구의 관리 또한 시설관리공단이나 위탁관리기관 등으로 분산되어 있어 일정한 시설물 설치기준이나 유지관리제도가 정립되지 못하여 효율적인 운영이 이루어지지 않다고 판단된다. 본 연구에서는 근래 국내에서 발생한 공동구 재해사례와 공동구 관련 법규를 검토 분석하였으며, 다양화되어 가는 공동구 수용시설 조건에 부합하고 체계적이고 효율적인 공동구의 시공을 위한 공동구 건설기준 제정방안을 도출하였다.

  • PDF

The Study on the Correlation Analysis between the Experienced Crime Victimization Rate and the Evaluation Indicator for Residents' Safety of Outdoor Spaces from Crime in Multi-Family Housing (공동주택단지에서의 범죄피해경험율과 범죄로부터의 안전성(safety) 평가 지표간의 상관성 분석에 관한 연구)

  • Lee, You-Mi
    • Journal of the Korean housing association
    • /
    • v.19 no.2
    • /
    • pp.73-82
    • /
    • 2008
  • The purpose of this paper is to analyze the correlation analysis between the experienced crime victimization rate and the evaluation indicator of residents' safety of outdoor spaces from crime in multi-family housing. Additionally this paper intend to analyze the correlation analysis between the residents' satisfaction about safety and the evaluation indicator of residents' safety of outdoor spaces. For that purpose, 9 Multi-Family Housing located in the metropolitan area were selected to perform a survey against 349 residents during May 26-29, 2006. The SPSS program was used and the level of satisfaction ranged from 1 to 5. Scale of 5 being most satisfied while 1 being most dissatisfied. The results of this study are the followings; 1) Most occurred crime were auto theft and damages, poster matter theft, housebreaking. 2) The crime rate is higher in outdoor than in indoor. 3) This study proved the correlation between the residents' satisfaction about housing safety and most indicators except the number of households etc. 4) By the results of the correlation coefficient it makes clear that the number of apartment building, the visibility of Green Space, the location of pedestrian etc. have relation with the residents' satisfaction about housing safety.