• Title/Summary/Keyword: 공기-물

Search Result 1,734, Processing Time 0.042 seconds

Application of Discoll Method to Blend Fine Aggregate for Concrete (콘크리트용 잔골재 혼합을 위한 Driscoll 방법의 적용)

  • Lee, Seong Haeng;Ham, Hyeong Gil;Kim, Tae Wan;Oh, Yong Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.178-185
    • /
    • 2011
  • Recently depletion of natural resources makes a deficiency of sand aggregation in the concrete works. In this study, the quality characteristics of concrete and aggregate according to blending fine aggregate in the river sand and the crash sand was analyzed by Normal method and Driscoll method which has used mixing of fine aggregate for asphalt mostly. Application of Discoll method to blend fine aggregate for concrete was studied in the first step to blend fine aggregates concrete. The fineness modulus, grading, slump, air content and compressive strength were tested by the two method, the results of Driscoll method was very similar to degree of err limits in comparison with those of Normal method in the same condition. As a result, Driscoll method is reasonable to use the fine aggregates mixture for concrete in river sand and crash sand.

Durability of Concrete Using Insulation Performance Improvement Materials (단열성능 향상 재료를 사용한 콘크리트의 내구성에 관한 연구)

  • Park, Young-Shin;Kim, Jung-Ho;Kim, Se-Hwan;Kim, Sang-Heon;Jeon, Hyun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.22-29
    • /
    • 2015
  • In this study, we tested to develop and apply structural insulation performance improvement concrete to field, which had compressive strength in 24 MPa and thermal conductivity twice as much as normal concrete. After experiment about slump and air contents, combination product of Plain and calcined diatomite powder showed reduction of slump and air contents and combination product with micro foam cell admixture, we cannot find result of slump and air contents reduction. Unit weight of combination product with insulation performance improvement materials decreased more than that of Plain. In the test of compressive strength, compressive strength of insulation performance improvement concrete decreased more than that of Plain but was content with 24 MPa. thermal conductivity of insulation performance improvement concrete tended to decrease. Freezing and thawing resistance of insulation performance improvement concrete was similar to that of Plain. In carbonation resistance test, combination product with calcined diatomite powder showed the result which was similar to that of Plain. In carbonation resistance test, combination product with micro foam cell admixture showed a increase compared to that of Plain and length variation of combination product generally increased.

A Study on Improvenment of Livingroom Smoke-control System using the FDS (화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구)

  • Kim, Mi-Seon;Baek, Eun-Seon
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.26-34
    • /
    • 2017
  • The purpose of this study is to identify and improve the performance of the adjacent room ventilation system in living room ventilation facilities, and compare and analyze the smoke control regulations of the NFPA code and the national fire safety standard (NFSC). The analysis method was fire dynamics simulation (FDS) and was used to analyze the, variations of the air supply amount, width of the boundary, change in indoor combustion and wind velocity of the incoming air. It was found to be advantageous to secure the clean layer when the amount of air supplied is less than the amount of discharged air in the fire room. However, in the supply room, it is more effective to secure the clean layer when the amount of supplied air is larger than the amount of discharged air, as a longer boundary width gives rise to better performance. In addition, it is necessary to consider the amount of air supplied and discharged as a function of the kind of flammable material. Moreover, decreasing the air inlet wind speed and amount of incoming air is advantageous for securing the clean layer of the fire room.

Investigation on Optimal Aeration Rate for Minimizing Odor Emission during Composting of Poultry Manure with Sawdust (계분톱밥 퇴비화시 악취발생의 최소화를 위한 적정 공기주입을 구명)

  • Kang, Hang-Won;Park, Hyang-Mee;Ko, Jee-Yeon;Lee, Jae-Saeng;Kim, Min-Tae;Kang, Ui-Gum;Lee, Dong-Chang;Moon, Huhn-Pal
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.4
    • /
    • pp.225-231
    • /
    • 2001
  • This study was conducted to find out the optimal aeration rates for minimizing odor emission and for increasing biological activities during composting of livestock manure in the enclosed bench-scale reactor system. It was treated with the mixture of poultry manure and sawdust controlled the initial water content of 60%, then aerated continuously at four different aeration rates (0.1, 0.2, 0.4 and 0.6 L/min/kg dry-solids). The average emitted concentration of ammonia in 0.6 L/min/kg dry-solids during composting reached the level of 40% in comparison with that of 0.2 L/min/kg dry-solids. In cases of sulfur compounds such as hydrogen sulfide, methylmercaptan and ethylmercaptan, their concentrations decreased with increasing aeration rates and the emission time was shortened. But they didn't detect in the treatment of 0.6 L/min/kg dry-solids. The biological activity for composting showed a trend of increasing as aeration rates increased. The treatment of 0.6 L/min/kg dry-solids gave the highest biological activity and the best compost quality.

  • PDF

Effects of Sterilization Temperatures and Internal Air Volumes of a Pouch on the Quality of Retort Rice (살균온도 및 포장재내 공기량이 레토르트 쌀밥의 품질에 미치는 영향)

  • Koh, Ha-Young;Park, Moo-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.150-154
    • /
    • 1990
  • Various sterilization temperatures $(110^{\circ}C,\;120^{\circ}C,\;130^{\circ}C)$ and air volumes (air, 31ml, half-vacuum; 13ml, vacuum; -0.7ml) within the retort pouch were tested for the development of the simple retort rice processing techniques in which the pouch were filled with rice and water, and then sterilized. Water content of retort rice was found to be 59.0-63.3% resulting from mixing the rice and water in the ratio of 1:1.1. The most uniform water content was obtained from retort rice sterilized at $130^{\circ}C$ and packaged under vacuum. The larger water content differences were observed with the increase in internal air volumes within the retort pouch. Spreading degree of retort rice was geater than that of general cooked rice, was lower in upper layer than in low layer, and became lower with the larger air volume and higher sterilization temperature. a degree of rice became higher with the Increase of sterilization temperature but that was not affected by the internal air volume of the pouch. The higher sterilization temperature and the lower the air volume, the higher the whiteness was. The highest whiteness was obtained by packaging under vacuum and sterilizing at $130^{\circ}C$. Intact degree was much higer in packaging under air than vacuum. In sensory evaluation the retort rice of vacuum pack was good in color and spreading degree but not in appearance because of blocking and deforming, but that of air pack was good in texture on the contrary. The best quality was obtained by packaging under half-vacuum and sterilizing at $130^{\circ}C$.

  • PDF

Plant Growth Responses and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System (벽면형 식물바이오필터 내 식물 생육 및 실내공기질 정화)

  • Jung, Seul Ki;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.28 no.5
    • /
    • pp.665-674
    • /
    • 2015
  • The final goal of this research is to develop a botanical biofiltration system, which combines green interior, biofiltering, and automatic irrigation, which can purify indoor air pollutants according to indoor space and the size of biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be more suitable for indoor space utilization. This study was performed to compare indoor air quality between the space adjacent to a botanical biofilter and the space away from the biofilter (control) without generation of artificial indoor air pollutants, and to evaluate plant growth depending on multiple floors within the biofilter. Each concentration of indoor air pollutants such as TVOCs, monoxide, and dioxide in the space treated with the biofilter was lower than that of control. Dracaena sanderiana ‘Vitoria’ and Epipremnum aureum ‘N Joy’ also showed normal growth responses regardless of multiple floors within the biofilter. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was effective for indoor air purification.

A Study on NOx Reduction of a Medium Speed Diesel Engine Using a Charge Air Moisturizer System (흡기가습 시스템을 이용한 중형엔진의 NOx 저감 기술 연구)

  • Park, Hyoung-Keun;Ha, Ji-Soo;Ghal, Sang-Hak;Park, Jong-Il;An, Kwang-Hean
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.21-22
    • /
    • 2006
  • 디젤엔진에서 배출되는 배기가스 중의 주요 오염물질 중의 하나인 NOx(질소산화물)는 대부분 고온의 연소 과정에서 발생하고, 발생량은 연소온도에 따라 결정되는 것으로 알려져 있다. 또한 연료의 연소 중에 물이 첨가되면 연소공기의 비열 증가에 의하여 연소온도가 감소하여 NOx 발생량이 급격하게 감소하게 되는데, 연소실에 물을 첨가하는 방법으로는 유화연료, 직접물분사, 흡기가습 등이 있다. 이중 흡기가습은 구조가 간단하면서 NOx 저감효율이 가장 높은 것으로 알려져 있다. 본 연구는 당사 고유모델 중형엔진인 힘센엔진에 흡기가습 기술을 적용하여 연소성능 및 NOx 저감효과 등을 시험하고, 흡기가습 시스템의 상용화 모델 개발을 위한 기초 데이터를 확보하기 위해 수행되었다.

  • PDF

부식환경에서의 파괴 및 피로

  • 이동영
    • Journal of the KSME
    • /
    • v.28 no.4
    • /
    • pp.313-321
    • /
    • 1988
  • 어떤 구조물이 반복하중을 받으면 피로파괴를 일으킨다. 만일 이 구조물이 부식환경 속에 앗 으면 불활성 분위기나 공기 중에서 보다 빨리 파괴에 이르게 된다. 이러한 현상을 흔히 부식 피로라고 한다. 부식피로에 크게 영향을 미치는 변수들을 대략 기계적 변수, 금속학적 변수, 환경 변수로서, 기계적 변수에는 최대응력 확대계수, 응력확대계수범위, 응력비, 반복하중 주파수, 반복하중파형, 응력상태, 잔류응력, 균열의 크기 및 모양 등이 있으며 금속학적 변수로는 합금 조성, 합금원소와 불순물의 분포, 미세조직과 결정구조, 열처리, 소성가공, 집합조직 등이며 환 경변수에는 온도, 환경의 형태(기체, 액체), 부식성분의 분압 또는 농도, 전기화학적 전위, pH, 수용성 환경의 점성, 피복, 부식억제제 등이 있다. 이와 같이 부식환경 속에 있는 구조물의 파 손을 이해하기 위하여는 응력부식과 부식피로를 공부하여야 한다. 이 현상은 매우 복잡한 문 제이기 때문에 아직도 완전히 이해되지 않은 상태이고 따라서 중요한 연구대상이 되고 있다. 여기서는 응력부식과 부식피로의 파괴역학적인 측면을 소개하고자 한다.

  • PDF

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

An Experimental Study on the dynamic behavior of 4-Span Cable-Stayed Bridge with ${\pi}$-Type Girder (${\pi}$형 거더를 가진 4경간 사장교의 동적거동에 관한 실험적 연구)

  • Cho, Jae-Young;Kim, Young-Min;Lee, Hak-Eun;Yoon, Ki-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.15-24
    • /
    • 2004
  • Generally, a ${\pi}$-type girder composed of two I-type girders is known to have a significant disadvantage in wind resistance design because of aerodynamic instability. A representative bridge for this girder was Tacoma Narrows Bridge. Since Tacoma Narrows Bridge had very low stiffness of the bridge structure and its cross-section shape had aerodynamic instability, the bridge collapsed after severe torsion and vibration events in 19m/s wind speed. Aerodynamic vibration can be avoided by enhancing structural stiffness and damping factor and conducting a study of cross-section shapes. This study shows the angle of attack for the four-span cable stayed bridge having ${\pi}$-type cross-section and describes the aerodynamic characteristics of the changed cross-section with aerodynamic vibration damping additions, by carrying out two-dimension vibration tests. As a result of uniform flow and turbulent flow, the study shows that because the basic ${\pi}$-type cross-section alone can have efficient wind resistant stability, there is no need to have additional aerodynamic damping equipment. Since this four 230m-main-span bridge has a large frequency and also has a big stiffness compared to other bridges containing a similar cross-section, it has aerodynamic stability under the design wind speed.