• Title/Summary/Keyword: 공기 흐름

Search Result 385, Processing Time 0.019 seconds

Variation of Air Temperature Inside Carbonate Area Caves (석회암 지역에 분포하는 동굴의 내부 온도 변동 특성)

  • Kim, Lyoun;Park, Youngyun;Lee, Jonghee;Choi, Jaehun;Jung, Qyusung;Kim, Jungtae;Kim, Insu
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.52-63
    • /
    • 2020
  • This study was conducted in order to evaluate the characteristics of air temperature fluctuation inside the Daegeumgul, Ondaldonggul, and Seongnyugul Caves, which are the most representative limestone caves in Korea, and also to assess the effects of air temperature on cave temperature. Temperature was measured hourly at three sites in Daegeumgul, Ondaldonggul, and Seongnyugul Caves from April 13 to June 25, 2019. Additionally, air temperature data for the areas around the caves was provided by the Meteorological Administration. Using this collected data, the basic statistical measure of fluctuation characteristics over time was ascertained, and time series analyses were performed. Wide variation of temperature was exhibited in the order of the cave entrance, the cave water inflow point, and the midpoint. Cave temperature was observed to increase gradually during the study period. There was a vast range in temperature at the Daegeumgul station located approximately 150 m outside the cave, but it remained nearly constant beyond the midpoint. Although the effect of air temperature was not significant due to the influence of visitors, the effect of air temperature on cave temperature gradually decreased from the entrance to the interior. At Ondaldonggul, there was a wide range in temperature recorded at the entrance due to the influence of air temperature, but it stayed almost constant in the interior. However, at the site where cave water flows into the cave, temperature was influenced by the cave water temperature. At Seongnyugul, there was a distinct fluctuation in temperature recorded at the cave entrance, while the middle of the cave remained nearly constant. Temperature fluctuated due to the air temperature at the entrance, while at the middle of the cave, measurements were expected to be affected to a greater extent by the lake water temperature than by the air temperature. However, this pattern was not observed. According to the time series analysis results, in all caves, fluctuations of air temperature affected cave temperature after approximately one hour. Cave size and structure, water presence, the entrance's size and shape, air flow, and visitor patterns can all influence cave temperature. Therefore, consideration of these factors is very important in the pursuit to clearly understand cave temperature characteristics.

Enhanced Bioslurping System for Remediation of Petroleum Contaminated Soils (Enhanced Bioslurping system을 이용한 유류오염 토양의 복원)

  • Kim Dae-Eun;Seo Seung-Won;Kim Min-Kyoung;Kong Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • Bioslurping combines the three remedial approaches of bioventing, vacuum-enhanced free-product recovery, and soil vapor extraction. Bioslurping is less effective in tight (low-permeability) soils. The greatest limitation to air permeability is excessive soil moisture. Optimum soil moisture is very soil-specific. Too much moisture can reduce air permeability of the soil and decrease its oxygen transfer capability. Too little moisture will inhibit microbial activity. So Modified Fenton reaction as chemical treatment which can overcome the weakness of Bioslurping was experimented for simultaneous treatment. Although the diesel removal efficiency of SVE process increased in proportion to applied vacuum pressure, SVE process was difficulty to remediation quickly semi- or non-volatile compounds absorbed soil strongly. And SVE process had variation of efficiency with distance from the extraction well and depth a air flow form of hemisphere centering around the well. Below 0.1 % hydrogen peroxide shows the potential of using hydrogen peroxide as oxygen source but the co-oxidation of chemical and biological treatment was impossible because of the low efficiency of Modified Fenton reaction at 0.1 % (wt) hydrogen peroxide. NTA was more efficiency than EDTA as chelating agent and diesel removal efficiency of Modified Fenton reaction increased in proportion to hydrogen peroxide concentration. Hexadecane as typical aliphatic compound was removed less than Toluene as aromatic compound because of its structural stability in Modified Fenton reaction. What minimum 10% hydrogen peroxide concentration has good remediation efficiency of diesel contaminated groundwater may show the potential use of Modified Fenton reaction after bioslurping treatment.

A Study on the Legislative Conception of Terror of the Advanced European Nations (유럽 선진국의 법제적 테러 개념에 관한 고찰)

  • Kwon, Jeong-Hun;Kim, Tae-Hwan
    • Korean Security Journal
    • /
    • no.15
    • /
    • pp.29-50
    • /
    • 2008
  • Many countries throughout the world have enacted laws on terrorism in the light of the changes that time has brought to them, geographical features, cultural values, and environmental elements. Especially some advanced European nations prescribe the definition of terrorism, the purpose of terrorism, the behavior of terrorism, and the types of crimes related to terrorism and so on for the following reason that it is more vital for the authorities concerned to investigate and punish terrorists after the rise of terrorism. In this regard, this paper analyzes legislative countermoves against terrorists of advanced countries such as France, Germany, and England and through this sheds light on the need of future anti-terrorism bills. The legislative basic guidelines directly to manipulate future terrors based on theories derived from this study could be summarized as follows. In the first place, providing laws on direct investigative power and harsher punishment to those involved in terrorism is a prerequisite for social security and thus the presidential directive of the state anti-terrorism action guidelines just deals with administrative measures without any effective response to terrorism. Hence it is urgent to make anti-terrorism bill concerning investigation and punishment of terrorists. In the second place, it is associated with the objectives of terror. The expression "all sorts of" stated in Korean law is so quite unclear that it can not fulfill the required conditions for naming it "crime". Comprehending provisoes of the crime that meets the purpose of the terrorists is necessary in order to investigate and inflict punishment on them. Therefore, it is advisable to establish specific and precise principles such as political, social, ideological, and religious purpose of terrorists in the bill. In the third place, to meet the flow of times of technicalization, informatization, such provisoes as destruction of electronic data system, crimes related to nuclear materials, purchases of weapons by terrorists, tax administration for prohibition of sale, and arson should be considered in terror bill. In the fourth place, nonselective attack toward unspecified individuals has become a serious issue in our society. Terrorists leave poisonous foods or beverages to crowded place or dump toxic chemicals into river intentionally. Therefore more strict regulations must be included in terror bill to prevent possible terrorist attacks.

  • PDF

Scheduling Algorithms and Queueing Response Time Analysis of the UNIX Operating System (UNIX 운영체제에서의 스케줄링 법칙과 큐잉응답 시간 분석)

  • Im, Jong-Seol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.3
    • /
    • pp.367-379
    • /
    • 1994
  • This paper describes scheduling algorithms of the UNIX operating system and shows an analytical approach to approximate the average conditional response time for a process in the UNIX operating system. The average conditional response time is the average time between the submittal of a process requiring a certain amount of the CPU time and the completion of the process. The process scheduling algorithms in thr UNIX system are based on the priority service disciplines. That is, the behavior of a process is governed by the UNIX process schuduling algorithms that (ⅰ) the time-shared computer usage is obtained by allotting each request a quantum until it completes its required CPU time, (ⅱ) the nonpreemptive switching in system mode and the preemptive switching in user mode are applied to determine the quantum, (ⅲ) the first-come-first-serve discipline is applied within the same priority level, and (ⅳ) after completing an allotted quantum the process is placed at the end of either the runnable queue corresponding to its priority or the disk queue where it sleeps. These process scheduling algorithms create the round-robin effect in user mode. Using the round-robin effect and the preemptive switching, we approximate a process delay in user mode. Using the nonpreemptive switching, we approximate a process delay in system mode. We also consider a process delay due to the disk input and output operations. The average conditional response time is then obtained by approximating the total process delay. The results show an excellent response time for the processes requiring system time at the expense of the processes requiring user time.

  • PDF

Simulation of Detailed Wind Flow over a Locally Heated Mountain Area Using a Computational Fluid Dynamics Model, CFD_NIMR_SNU - a fire case at Mt. Hwawang - (계산유체역학모형 CFD_NIMR_SNU를 이용한 국지적으로 가열된 산악지역의 상세 바람 흐름 모사 - 화왕산 산불 사례 -)

  • Koo, Hae-Jung;Choi, Young-Jean;Kim, Kyu-Rang;Byon, Jae-Young
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.192-205
    • /
    • 2009
  • The unexpected wind over the Mt. Hwawang on 9 February 2009 was deadly when many spectators were watching a traditional event to burn dried grasses and the fire went out of control due to the wind. We analyzed the fatal wind based on wind flow simulations over a digitized complex terrain of the mountain with a localized heating area using a three dimensional computational fluid dynamics model, CFD_NIMR_SNU (Computational Fluid Dynamics_National Institute of Meteorological Research_Seoul National University). Three levels of fire intensity were simulated: no fire, $300^{\circ}C$ and $600^{\circ}C$ of surface temperature at the site on fire. The surface heat accelerated vertical wind speed by as much as $0.7\;m\;s^{-1}$ (for $300^{\circ}C$) and $1.1\;m\;s^{-1}$ (for $600^{\circ}C$) at the center of the fire. Turbulent kinetic energy was increased by the heat itself and by the increased mechanical force, which in turn was generated by the thermal convection. The heating together with the complex terrain and strong boundary wind induced the unexpected high wind conditions with turbulence at the mountain. The CFD_NIMR_SNU model provided valuable analysis data to understand the consequences of the fatal mountain fire. It is suggested that the place of fire was calm at the time of the fire setting due to the elevated terrain of the windward side. The suppression of wind was easily reversed when there was fire, which caused updraft of hot air by the fire and the strong boundary wind. The strong boundary wind in conjunction with the fire event caused the strong turbulence, resulting in many fire casualties. The model can be utilized in turbulence forecasting over a small area due to surface fire in conjunction with a mesoscale weather model to help fire prevention at the field.