• Title/Summary/Keyword: 공기 정화

Search Result 279, Processing Time 0.021 seconds

Monitoring of Microbial Contamination in Air Purifier for Preventing Cross-contamination (교차오염방지를 위한 공기정화제품에서 미생물 오염도 분석)

  • Yeom, Seung-Mok;Kim, Young-Mog;Lee, Myung-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • Many atmospheric pollutants including chemical agents, house dust, and microorganisms cause building-related illnesses through respiration in humans. This study was conducted to analyze the profiles of microbial pollutants in air purifiers used in home, office and playschool. Dominant eleven species of microorganisms were isolated and identified in environmental air and air purifiers. Among them, Staphylococcus sp., Micrococcus sp. and Bacillus sp. are the most dominant species. By phylogenetic analysis of the 16S rRNA gene, the dominant bacteria were identified as Staphylococcus epidermidis, Micrococcus luteus and Bacillus epidermidis, respectively. It has been known that these bacterial species are closely related with food spoilage and human infectious disease. Thus, these results indicate that microbial pathogens related with human illnesses through respiration will be contaminated in air purifiers and also need to develop a method to control those of pathogens for human health.

Development of air-sterilization purification system of fusion and composite structure using broadband-to-active photocatalyst (광대역대 활성광촉매를 활용한 융·복합 구조 공기살균정화장치 개발)

  • Yoon, Sueng-Bae;Hwang, Yun-Jung;Kim, Seung-Cheon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.147-151
    • /
    • 2019
  • Modern people spend most of their daily lives in their homes, schools, or workplaces, hospitals, shopping malls, subway stations, rooms, and parking lots. According to the survey, air quality management at the multi-use facility is less than 50% satisfied. In this study, a photocatalytic filtration system is developed by utilizing a broadband-to-active photocatalyst that utilizes a media photocatalyst filter that removes airborne germs from indoor air as well as indoor air quality and operates on visible light as well as ultraviolet light.

The Indoor Air Purification System Using LED and Fan for Epipremnum aureum (스킨답서스에 LED와 Fan을 이용한 실내공기정화 시스템)

  • Kim, Taehyun;Park, Junmo;Kim, Soochan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.4
    • /
    • pp.167-173
    • /
    • 2018
  • We propose an air purification system that utilizes aerial plant parts and root zone of indoor plants where light is insufficient and air circulation is bad. In order to maximize the air purification effect of the plant, the aerial plant parts illuminates mixed light combining blue and green LED and CRI(Color Rendering Index) LEDs close to natural light, respectively. And the root zone was forcibly circulated by the fan to use the soil as a filter. The indoor air purification system combined with the light source and the fan removed most polluted air in the shortest. In the case of mixed light and CRI LEDs of indoor air purification system, fine dust decreased by 14%, 14.2%, and TVOC(Total volatile organic compounds) decreased by 7.5% and 9.4%, respectively. In the experiment in which the fan was operated for 15 minutes, the TVOC decreased to 97.8%. The photosynthesis of the plant and the use of soil as a filter were able to purify polluted air in a short time. And the fan's temporary operation gave the similar effect of continuous operation.

공기정화필터 프레임 재사용과 그에 따른 효과 고찰

  • 윤철종;송대원;장동철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.194-195
    • /
    • 2005
  • 방사선관리구역 내에서 발생되는 많은 양(발전소별 연간 약$100{\sim}700$개 정도)의 사용 후 공기정화 필터는 고체 폐기물 드럼의 단면적 보다 넓어 별도로 필터를 압축하거나 분해 작업 없이는 폐기물로 직접 처리가 곤란하다. 처리 시 많은 양의 분진이 발생하여 작업자의 내부피폭 가능성 및 많은 양의 고체 폐기물이 발생할 수 있는 잠재성이 있어 시료분석 결과 오염된 필터 내지는 바로 드럼 처리하여 내부 피폭 가능성을 미연에 방지하고 필터 프레임은 재사용을 유도하여 폐기물 저감화, 작업환경 개선 및 경제적인 이익을 창출할 수 있다. 영광 3발전소와 울진 3발전소의 경우 타 발전소에 비해 방사선관리구역 내 공기정화 처리기의 설치수량이 많아(약 700개/년) 공기정화필터가 매년 다수 발생되고 있으며, 이를 전량 드럼 처리 시 고체폐기물 드럼이 더 발생하게 되어 영구처분비용의 증가를 초래하게 된다. 발전소 전체적으로는 약 3,500개/년의 폐필터가 발생되고 있다. 이렇게 발생되는 공기정화필터의 프레임을 재사용함으로써 그 효과는 1) 알루미늄을 포함한 유리섬유를 드럼처리 시 고체방사성 폐기물드럼 생성량 감소 2) 프레임 재사용으로 인한 예산절감 효과 3) 폐필터 분해작업 시 분진에 의한 작업자 체내${\cdot}$외 피폭방지와 작업장 오염 확산 방지 및 환경 개선 4) 작업시간 단축 및 소요인력 감소 효과를 볼 수 있다.

  • PDF

실내 오염방지를 위한 공기정화 장치법

  • 문길주
    • Journal of the KSME
    • /
    • v.32 no.3
    • /
    • pp.290-299
    • /
    • 1992
  • 대기질의 악화와 오염원이 많아짐에 따라, 실내공기 정화장치 또한 재래식의 방법을 벗어난 방 식으로 설계 시설되어야 한다. 인위적으로 만들어진 유해 물질과 작은 먼지들을 제거하기 위한 새로운 환풍장치는 지역의 특수성을 고려하여 설계되어야 한다. 더욱이 대도시의 생활은 오염 원과 작업장 및 거주지가 가까이 위치하기 때문에 특별히 지역의 특수성을 고려하여 환풍장치가 설계되어야 한다. 끝으로 작업장안에서 오염원 격리수용하는 것은 매우 바람직하여, 청정공 간(clean room)을 요구하는 반도체 및 제약회사 등은 건축물자체 오염원에서 멀리 떨어져서 지 역의 영향을 최소화하는 것과 건축물의 자재 및 공기정화장치가 새롭게 연구되어 설계되야 한다.

  • PDF

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

Photochemical Oxidants Damage in Rice Plants (Photochemical Oxidants에 의한 수도피해(水稻被害) 해석(解析))

  • Jeong, Young-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.2
    • /
    • pp.103-107
    • /
    • 1983
  • The effect of photochemical oxidants on rice plants was measured by growing the rice plants Nihonbare in pot in charcoal-manganese oxide filtered atmosphere and non-filtered air. Visible injury on the leaf blades of rice plants were observed in plants grown under the unfiltered air chamber, but plants under filtered air chamber were free from any injury. Fresh weight of stem and root at maximum tillering stage in unfiltered chamber were 16.8 and 46.4% less than filtered air chamber, respectively. Grain yield in unfiltered air chamber was also reduced by 14.7% compared to that of filtered air chamber. And the reduced yield paralleled increase in concentration of oxidants in the atmosphere at the experimental site. ABA content in rice plants cultivated in unfiltered air chamber was higher than in filtered air chamber, but the root activity of rice plants in unfiltered air chamber was remarkably decreased.

  • PDF

Comparing the Effects of Ventilation and Air Purification Plants on Radon Concentration in the Lower and Upper Floors of a Building (건물 저층과 고층에서 환기와 공기정화 식물을 통한 라돈 농도의 비교)

  • Gong, Yu-jin;Nam, So-Yeong;Shin, Min-Seo;Jang, Hey-Rim;Jeon, Min-Cheol;Yoo, Se-Jong;Kim, Seong-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.881-889
    • /
    • 2020
  • The objective of this study was to quantitatively measure the changes in radon concentration due to ventilation and air purification plants in the lower and upper floors of a building. This study measured and compared radon concentration in the lower and upper floors of the building by using a radon meter when the room was closed, it was ventilated, and air purification plants were installed at a specific time. One-way ANOVA was conducted to evaluate the effect of treatment (i.e., closure, ventilation, and air purification plants) on radon concentration. The results of this study showed that ventilation and air purification plants significantly decreased radon concentration in the lower and upper floors of the building, but the effect of ventilation and that of air purification plants were not significantly different. Therefore, it will be possible to reduce radon concentration effectively when ventilation and air purification plants are used appropriately.

토양의 특성에 따른 토양증기추출법 (Soil Vapor Extraction)의 Trichloroethylene (TCE)과 Toluene 정화 효율 실험

  • 강현민;이민희;정상용
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.191-194
    • /
    • 2002
  • 토양증기추출(Soil Vapor Extraction)법을 이용하여 대표적 휘발성 NAPL (Non-aqueous phase liquid)인 TCE (trichloroethylene)와 toluene을 토양으로부터 제거하는 칼럼 실험을 실시하였다. 토양특성 및 증기추출 조건들이 정화효율에 미치는 영향을 규명하는데, 균질한 Ottawa sand와 실제 오염지역의 토양들을 직경 2.5cm, 길이 30cm인 유리 칼럼이 충진시켰으며, 빨갛게 염색된 TCE 또는 toluene 4 g이 주입되었다 공기 유량계를 설치하여 0.03L/min의 일정한 속도로 공기가 주입되도록 하고, 퍼지장치를 설치하여 주입 공기의 습윤도를 99% 이상으로 유지하였다. 가스크로마토그래피로 유출 가스 농도를 분석하였다. Ottawa sand로 충진된 칼럼실험에서는 매질의 입자크기, 함수율, 토양 내 오염물 체류시간 등을 변화시켜 실험을 반복하였다. TCE로 오염된 세립질 Ottawa sand 칼럼실험에서 유출 공기의 최대 농도는 조립질 Ottawa sand 칼럼의 유출 농도보다 약 20% 정도 감소하였고, 오염지역의 실제토양 칼럼실험에서는 최대유출농도가 조립질 Ottawa sand 칼럼의 농도보다 약 50% 감소하였으나, 20 liter공기 주입 후부터는 모두 비슷한 농도감소 현상을 나타내었으며, 초기 주입량의 90 % 이상이 제거되었다. 함수율증가에 따른 유출공기의 농도 감소는 거의 나타나지 않았으며, TCE 주입 후 7일 동안 방치하였다가 SVE를 실시한 칼럼 실험에서도 잔류하는 TCE의 양이 약간 증가하였지만 20 liter 공기 추출 후에는 초기 주입량의 90% 가, 40 liter공기 추출 후에는 98% 이상이 제거되었다. Toluene으로 오염된 칼럼 실험에서도 TCE와 비슷한 제거 경향을 나타냈으며 200 liter 공기 추출 후에는 오염물 초기 주입량의 98% 이상이 제거되었다. 본 실험 결과로부터 증기추출법을 이용한 TCE, toluene 정화 효율성이 규명되었으며, 휘발성 NAPL로 오염된 실제 토양을 복원하기 위한 SVE법의 적용가능성을 확인할 수 있었다.

  • PDF