• Title/Summary/Keyword: 공기 부상

Search Result 164, Processing Time 0.046 seconds

Evaluation of a Propulsion Force Coefficients for Transportation of Wafers in an Air Levitation System (공기부상방식 반도체 웨이퍼 이송시스템의 추진력계수)

  • 문인호;황영규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.820-827
    • /
    • 2004
  • The propulsion force acting on a wafer in an air levitation system was measured accurately and then, the corresponding force coefficient was determined. The theoretical propulsion force on the wafer bottom surface were obtained by CFD simulations and from these results the propulsion force coefficient was deduced. The transportation velocity of a wafer was estimated by using both experimental and numerical force coefficients, for various air velocity of nozzle injection. When the numerical results are compared to the experimental data, the numerical results agree well Quantitatively.

Characteristics of Autoignited Laminar Lifted Flames in Heated Coflow Jets of Carbon Monoxide/Hydrogen Mixtures (일산화탄소/수소 혼합기의 가열된 동축류 제트에서 자발화된 층류 부상화염의 특성)

  • Choi, Byung-Chul;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.639-646
    • /
    • 2012
  • The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process.

Development of Air-floating Conveyor System for FPD (FPD용 공기부상 이송컨베이어 시스템 개발)

  • Lho, Tae-Jung;Lee, Wook-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • The CRT(Cathode Ray Tube) displays have been substituted for FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) because they have a convex surface, large volume and heavy weight. The productivity of FPDs is greatly dependent on the area of thin glass panel with $0.6{\sim}0.8mm$ thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass Panel. Through FEM(Finite Element Method) analysis and fluid analysis, we developed an non-contact and air-floating conveyor system which consists of transport-module, distributor, horizontal/vertical changer and controller for the 7th generation glass panel (2,200mm in width, 1,870mm in length and 0.7mm in thickness). The design technology developed in this study can be effectively applied to a conveyor system for a larger-scaled thin glass panel.

Applicability Evaluation of Precast Deck to the Maglev Guideway System : Mock-Up Construction Test (프리캐스트 바닥판의 자기부상열차 가이드웨이 시스템 적용성 평가 : 모의 시공 실험)

  • Jin, Byeong-Moo;Kim, In-Gyu;Kim, Young-Jin;Oh, Hyung-Chul;Ma, Hyang-Wook;Lee, Yung-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.57-60
    • /
    • 2008
  • Maglev is a system that a train runs levitated above a rail. Therefore it is very important to maintain a constant levitation gap for achieving serviceability and ride comfort. This study is a cooperation research subject of the 3-1 subject, performance improvement of maglev track structures, of the Center for Urban Maglev Program in Korea, started in 2006. The aim of this study is development of rapid constructions of bridge superstructure for maglev. At present, precast deck is widely used because of its superiority to cast-in-place concrete on quality and the term of works. The research group suggested basic systems of maglev guideway with PSC-U type and trapezoidal open steel box type girder, and precast deck, cooperating with Korea Railroad Research Institute, the managing institute of the 3-1 subject. In this study, a mock-up consisted of girders, decks and rail was fabricated and test was performed for constructability, serviceability and maintenance evaluation of PSC U-type girder, precast deck, and new guide rail system.

  • PDF

A Study on Flying Height of Head Slider in Rotary Type Actuator (회전 구동용 헤드 슬라이더의 부상높이에 관한 연구)

  • 이재헌;최동훈;윤상준;김광식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1886-1896
    • /
    • 1991
  • This paper presents a method to predict the flying height of the head slider in a hard disk drive. Quantitative predicts of the flying height according to the variations of the external load and the disk velocity have been done by numerical computation. In addition, the magnitude of the external load to keep flying height constant were also suggested. The Modified Reynolds' equation driven from hydrodynamic lubrication theory under slip flow condition was used to describe air-bearing system under the slider. To solve the equation, a Finite Volume Method (FVM) has been applied. To determine the final minimum flying height and pitch angle of the head slider, the Secant iteration method is used which update initial guess of the minimum flying height and pitch angle of the slider. In this study, the model head slider has been selected from a real hard disk drive which is equipped in many commercial personal computers. As a result, as the disk velocity increases at constant external load, the minimum flying height and the pitch angle increase due to the in crease of the air-bearing force at the bottom of slider.

Nitrogen Dilution Effects on Liftoff Flame Stability in Non-premixed Turbulent Hydrogen Jet with Coaxial Air (질소희석이 부상된 수소 난류확산화염의 화염안정성에 미치는 영향)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.393-396
    • /
    • 2008
  • The study of nitrogen dilution effect on flame stability was experimentally investigated in non-premixed turbulent lifted hydrogen jet with coaxial air. hydrogen gas was used as a fuel and coaxial air was injected to make flame liftoff. And both of the fuel jet and coaxial air velocity were fixed as $u_F$=200 m/s and $u_A$=16 m/s, while nitrogen diluents mole fraction was varied from 0 to 0.2. For the analysis of flame structure and flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF had been performed. It was found that the turbulent flame propagation velocity increased as decreasing of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity, even though the mole fraction of nitrogen diluents gas was changed.

  • PDF

Numerical Study of Effect of DAF-Tank Shape on Flow Pattern in Separation Zone of Dissolved Air Flotation (용존공기부상조(DAF-tank)의 형상변화가 분리조(Separation Zone)의 내부 유동 패턴에 미치는 영향에 대한 수치해석적 연구)

  • Ryu, Gwang-Nyeon;Park, Sang-Min;Lee, Ho-Il;Chung, Mong-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.855-860
    • /
    • 2011
  • We numerically simulated a dissolved air flotation (DAF) tank to predict the performance of the pilot facility. The flow was assumed to be two-dimensional and two-phase. The velocity distributions in the separation zones of differently shaped DAFs were compared to find the effect of the shape on the performance. The results showed that the typical flow pattern that appeared in a well-designed DAF-tank was generated in the separation zone of the base model. This flow pattern could be maintained while the baffle height was sufficiently tall regardless of the other geometric parameters. However, the baffle height and angle, the contact zone width, and the perforated plate affected the uniformity of the downward flow in the separation zone. Except for the baffle height, the base model used in this study showed a better uniformity of downward flow than did other models with different geometric parameters.

Thickening of Activated Sludge Using Low Pressure Flotation Pilot System (파일롯 규모의 저압형 부상장치를 이용한 하수슬러지 농축에 관한 연구)

  • Kim, Ji Tae;Oh, Joon Taek;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Low pressure air flotation (LAF) pilot plant for sludge thickening was installed in Chung Nam N.S. municipal waste water treatment plant to verify its application possibility. Effects of operating conditions such as coagulant dosages and microbubble water ratio on thickening of the mixed sludge were examined. Microbubbles which were generated in the chamber of $1.5kgf/cm^2$ by high speed collision method with foaming agent were used to float sludge. Solid loading of $30kg/m^2/hr$, solid contents in thickened sludge of 60,300 mg/L and SS removal efficiency of 99% were obtained through long period operating LAF in conditions of mixed sludge concentration of 14,400 mg/L, coagulant dosage of 27.6 mg/L, foaming agent addition of 4.0 mg/L and microbubble water injection ratio of 9.7%.