• Title/Summary/Keyword: 공기 냉각기

Search Result 138, Processing Time 0.019 seconds

업체탐방 - 원유냉각기 제조에서 유가공기기 설비까지 확장, 제2의 도약을 맞이하고 있는 (주)삼호씨티

  • 한국낙농육우협회
    • 월간낙농육우
    • /
    • v.35 no.11
    • /
    • pp.109-112
    • /
    • 2015
  • 30여 년의 냉각기 제조 기술로 국내 원유냉각기 시장의 40%를 차지하고 있는 (주)삼호씨티(대표 김태삼)가 유가공기기 및 설비 기술로 또 한 번의 전성기에 돌입했다. 이미 포화상태에 있는 국내 원유냉각기 시장을 넘어 일본에 원유냉각기를 수출하고 있는 삼호씨티는 이제 그동안 현장에서 축적해 온 기술력을 바탕으로 유가공 기기까지 순수 국내기술로 제조해 판매함으로써 유럽의 원유냉각기와 경쟁하고 있다.

  • PDF

Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler (곡물냉각기를 이용한 철제 원형빈에서 벼 냉각)

  • 김의웅;김동철
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.263-268
    • /
    • 2004
  • Two field cooling tests were conducted to evaluate the cooling characteristic of paddy with a prototype grain cooler. The first test was carried out during summer season in a steel bin with 180.3ton of paddy at Sunchon. And the second test was carried out during harvesting season in a steel bin with 272.2ton of paddy at Ulsan. At the first test, initial paddy temperature of 23.6$^{\circ}C$ was dropped to 14$^{\circ}C$, and initial moisture content of 19.9% was dropped to 19.3% after 52.5 hours of cooling. At the second test, initial paddy temperature of 16.1$^{\circ}C$ dropped to 5.5$^{\circ}C$ after 78.0 hours of cooling. And, at the first test, the average air flow rates of chilled air leaving the grain cooler and penetrating the grain layer were 77.5 ㎥/min and 42.5 ㎥/min, respectively. To prevent leakage of chilled air from plenum chamber of steel bin, which was about 45% of the average air flow rates of chilled air leaving the grain cooler, a proper method was required. The average total power consumption at the first test during summer was 22.1 ㎾ with control of fan damper. At the second test, it was 17.4 ㎾ due to controlling the capacity of compressor with unloading solenoid valve and changing the flow rates of hot refrigerant gas flowing into evaporator and reheater from compressor, resulting in 27% reduction of energy consumption.

A Unified Theoretical Treatment for Thermal Analysis of Cooling Towers, Evaporating Condensers, and Fluid Coolers (냉각탑, 증발식 응축기 및 밀폐식 냉각탑의 전열해석을 위한 통일이론)

  • Ryu, Hae-Seong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.67-81
    • /
    • 1986
  • 냉각탑, 밀폐식냉각탑, 증발식응축기는 증발식냉각기의 분류에 속한다. 열은 증발에 의해 제거되어, 중력에 따라 유하하는 수 film으로 부터 충전물, 또는 밀폐식냉각탑, 증발식응축기의 관군상을 흐르는 공기에 전달된다. 따라서 공기측에서의 열과 물질의 이동프로세스는 기본적으로는 동일하다. 각 형식에서의 차이는 냉각되는 유체측에서의 열저항의 형태가 다르다는 점이다. 이 무저항은 냉각탑에서는 아주 작으나 다른 두 경우에 있어서는 계산상 고려하지 않으면 안된다. 이 논문은 이들 세 형식에 대해 통일된 이론을 적용할 수 있다는 것을 보여주기 위한 것이다. 그러므로 열 및 물질이동저항의 계산을 위한 식에 대해 논의하고 있다. 또한 복잡성을 피하기 위해, Merkel의 근사식을 공기측의 열 및 물질이동계산에 이용하였다.

  • PDF

Analysis of Temperature Distribution of Solid and Gas in the Rotary Cooler (회전냉각기에서 고체와 가스의 온도분포해석)

  • 이만승;최주석;전철근
    • Resources Recycling
    • /
    • v.11 no.3
    • /
    • pp.25-30
    • /
    • 2002
  • Heat transfer occurring in the rotary cooler was analyzed by applying a one-dimensional steady state. The temperature of inlet gas and the measured temperature of outlet gas were used as boundary conditions. Axial temperature distribution of solid, gas and wall were calculated by solving two differential equations and two algebraic equations under the constraint of two point boundary conditions and operating conditions. The temperatures of outer wall calculated in this study were in good agreement with those measured from running rotary cooler.

On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor (CDA 인입공기 증발냉각을 통한 압축기 성능 개선장치 개발 연구)

  • Kim, Gyu Wan;Park, Jin Ouk;Kim, Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.873-879
    • /
    • 2014
  • In the present study, water vapor is injected at various positions in a Clean Dry Air (CDA) system such as a system inlet duct, compressor inlet, and compressor outlet by humidified air turbines. The application of evaporative cooling reduces the compression work and enhances the Energy Consumption Index (ECI) per unit volume. The main purpose of this study is to investigate the compressor power performance with different inlet air temperatures and humidity conditions. It is found that the actual power consumption and discharge flow are significantly influenced by the inlet air temperature as well as relative humidity. The results obtained during this study are compared both numerically and experimentally and are found to be in very good agreement.

전력기기의 에너지절약 및 이용 합리화

  • KOREA ELECTRIC ASSOCIATION KOREA ELECTRIC ASSOCIATION
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.309
    • /
    • pp.83-87
    • /
    • 2002
  • 전력계통에서의 발전, 송변전, 배전의 각각에 대한 에너지절약 및 이용 합리화를 미쓰비시(삼릉)전기는 여러 방면에서 노력하고 있으며, 여기서는 전력기기에 대한 그간의 노력에 대하여 기술한다. 발전에 관해서는 공기냉각과 수소냉각 터빈발전기의 효율 향상으로 성(省)에너지화를 지향하고 있다. 동사에서는 세계 최대급의 공기냉각 터빈발전기를 제작하여 수소냉각기와 거의 동등한 높은 효율을 얻고 있다. 송변전에 대해서는 전력용 대형 변압기의 본체 체적 축소, 신(新)절연구조의 채용으로 대형변압기의 설치면적을 반감시키고 손실저감도 실현시킬 수 있었다. 성숙기종으로 생각되는 분야에 대해서도 새로운 발상으로 더욱 개선해 나갈 계획이다. 배전분야에 대해서는 전력의 합리적 사용이나 고효율 변압기의 채용에 의한 전력삭감 등 필요성이 재검토되고 있다. 동사에서는 배전설비 구성의 일익을 담당하는 손실이 극히 적은 수퍼 고효율 유입변압기를 개발, 배전분야에서 활용되고 있다. 성(省)에너지를 위한 발전기의 응용 예의 하나로 자연에너지를 이용하는 풍력발전을 들 수 있다. 동사가 개발하여 실용화되고 있는 풍력발전기는 회전자 자극(磁極)에 영구자석을 사용한 동기발전기를 사용하고 있어, 여자장치나 기어기구가 불필요하여 전기적, 기계적인 손실을 경감시키고 있다.

  • PDF

Mixing Augmentation with Cooled Pylon Injection in Scramjet Combustor (냉각 파일런 분사를 이용한 스크램제트 연소기 내 혼합증대)

  • Lee, Sang-Hyeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.20-28
    • /
    • 2010
  • The mixing characteristics of pylon injection in a Scramjet combustor and effects of film cooling to protect pylon from air-heating were investigated. Three-dimensional Navier-Stokes equations with $k-{\omega}$ SST turbulence model were used. Fuel hydrogen and air were considered as coolants. There were remarkable improvements of penetration and mixing rate with the pylon injection. There was also over-heating on the front surface of the pylon without film cooling. The coolant injected parallel to the front surface of the pylon protects the pylon from over-heating.

A Numerical Study on the Combustion Characteristics in a Liquid Rocket Engine with Film Cooling Effect (막냉각 효과를 고려한 액체로켓 엔진의 연소 특성에 관한 연구)

  • Byeon,Do-Yeong;Kim,Man-Yeong;Baek,Seung-Uk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.69-76
    • /
    • 2003
  • For stable combustion and safety of a structure of the propulsion system, a cooling system to the liquid rocket engine should be incorporated. In this study, Eulerian-Lagrangian scheme for two phase combustion, nongray radiation and soot formation effect, and film-wall interaction have been introduced to study the effect of film cooling. After briefly introducing the governing equation, combustion characteristics with change of wall temperature has been investigated by varying such parameters as fuel mass fraction for film cooling, diameter of the fuel droplet, overall mixture fraction of oxygen to fuel. Also, radiative heat flux is compared with the conductive one at the combustor wall.