• Title/Summary/Keyword: 공기의 저항

Search Result 496, Processing Time 0.032 seconds

Parametric Study on the Capacity of Vacuum Pump for Tube Structure (튜브열차 구조물의 진공 펌프 용량에 관한 파라메타 연구)

  • Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.516-520
    • /
    • 2010
  • Parametric study has been conducted to calculate the capacity of vacuum pump system that will be used to maintain the pressure of the tube structure under atmosphere level. Recently many railroad researchers pay attention to the tube train system as one of the super high speed transportation system. To achieve the super high speed, the inside of tube system should be maintained at low pressure level. In the low pressure environment, it is well known that air resistance of train is drastically decreased. Vacuum pump system will be used to make low pressure state for tube structure, exhaust the leakage air and supplement additional vacuum pumping. As results of these studies, we get the lump capacity of vacuum pump for various parameters. These results can be applied to analyze the effects of the reduction of air resistance.

Super-hydrophobic Electrodeposited Zinc Layer for Anti-Corrosion by Phosphatization (인산염처리를 이용한 방식용 초발수성 아연 도금층)

  • Jeong, Hae-Chang;Kim, Wang-Ryeol;Gang, Min-Ju;Kim, Gwon-Hu;Lee, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.78-78
    • /
    • 2018
  • 전기 아연도금은 철강의 내식성을 향상시키기 위한 희생양극으로 사용되어 왔다. 이러한 아연 도금층의 내식성은 그 아연에 의하여 부식으로부터 보호받는 철강 소재의 수명과 직결됨에 따라 아연 도금층의 성능 특히 부식저항성을 높이는 연구는 소재 수명 뿐만이라 성능의 유지하는데 있어서 매우 중요하다. 본 연구에서는 전기 아연 도금층에 표면에너지가 낮은 물질인 테플론을 얇게 코팅함으로써 발수성 표면을 구현하였다. 발수성 표면은 물에 대한 젖음성이 매우 낮기 때문에 부식 저항성이 높은 것으로 알려져 있는데, 이는 표면의 거칠기를 제어함으로써 그 효과를 극대화 할 수 있다. 본 연구에서는 특히 전기 아연 도금의 후처리로 알려진 인산염 처리를 이용하여 전기 아연 도금층의 표면형상 구조를 제어하였다. 그리고 그 표면에 테플론을 코팅함으로써 초발수 성질을 구현하였고, 이를 통해 아연 도금층의 내식성 향상에 대하여 분석하였다. 그 결과, 인산염처리에 의하여 표면형상의 구조가 거칠어질수록 테플론 코팅 후 접촉각과 물방울의 이동성은 증가하였다. 이는 표면형상에 의해서 공기층이 물방울 아래에 고립되어 있다는 것을 의미하고, 이러한 공기층으로 인하여 아연 도금층의 내식성은 크게 증가하였다.

  • PDF

A Study on the Necessary Thrust of Tugs through the Ship's Towing Test (실선 예항시험을 통한 예인선의 소요마력 산출에 관한 연구)

  • Jung, Chang-Hyun;Nam, Taek-Kun;Choi, Hyuek-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.405-411
    • /
    • 2014
  • It needed the calculation of the required tugboat's power to move the damaged vessel to the safe area for reducing the additional damages. In this paper, it was verified the theoretical calculation method on the required power of tugboat through the 93m real ship tests. From the experiments, it was considered that the theoretical calculation method was sufficient to estimate the required power of tugboat. The resistance of the locked propeller was relatively big portions compared with other static resistances such as air resistance, frictional resistance and residual resistance. And dynamic resistance induced by swing movement and yawing was continuously occurred and it also was great effects on the total resistance. In the future, the safety factor will be considered and the exact prediction of ship's resistance will enhance the efficiency of tugboat because of the minimization of safety factor.

Evaluation of Segment Lining Fire Resistance Based on PP Fiber Dosage and Air Contents (세그먼트 라이닝의 PP섬유 혼입량과 공기량 변화에 따른 화재저항 특성 평가)

  • Choi, Soon-Wook;Kang, Tae Sung
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.469-479
    • /
    • 2021
  • As a material for preventing spalling of concrete, the effectiveness of PP fiber has already been confirmed. However, it is necessary to consider the maximum temperature that occurs during a fire, and to solve the mixing problem and the strength reduction problem that occur depending on the mixing amount. In this study, the fire resistance performance of tunnel segment linings according to the PP fiber content and air volume under the RABT fire scenario was investigated. As a result, no spalling or cross-sectional loss occurred in all test specimens, and when the PP fiber content was small, the maximum temperature was relatively high and the maximum temperature arrival time was also fast. On the other hand, no trend was found for the maximum temperature and arrival time according to the difference in air volume. In the internal temperature distribution results for the PP fiber mixing amount of 0.75, 1.0, 1.5, and 2.0 kg/m3, the results of 0.75 and 1.0 kg/m3 showed similar temperature distribution, and the results of 1.5 and 2.0 kg/m3 were similar. It was confirmed that the internal temperature distribution tends to decrease at the same depth when the amount of PP fiber mixed is large, and it was confirmed that a remarkable difference occurred from the results of 1.0 kg/m3 and 1.5 kg/m3 of PP fiber mixed amounts.

Study on the Evaluation of Frictional Drag Reduction by Air Lubrication and the Arrangement of Air Injection Parts for a Liquefied Natural Gas Carrier (공기윤활에 의한 액화천연가스운반선의 마찰저항저감 평가 및 공기 분사부 배치에 대한 연구)

  • Kim, Hee-Taek;Kim, Hyoung-Tae;Kim, Hyun-Joe;Kim, Jung-Joong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.3
    • /
    • pp.144-157
    • /
    • 2021
  • Brake Horse Power (BHP) reduction ratios by air injection to the underside of the hull surface in an actual ship are predicted using an unstructured finite-volume CFD solver and compared with the sea trial results. In addition, air lubrication system installed on the existing vessel is investigated to find a good solution for additional drag reduction. As a results, it is found that the thickness of the air layer should be minimized within a stable range while securing the area covered by the air layer as much as possible. Furthermore, the amount of frictional drag reduced by air injection is found to be independent of surface roughness and still effective on rough surface. Based on the results of this study, it is expected that systematic and reliable air lubrication system can be designed and evaluated using the proposed method.

Effects of Fouling Reduction by Intermittent Aeration in Membrane Bioreactors (MBR에서 간헐포기에 의한 오염저감 효과)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.276-286
    • /
    • 2015
  • The effects of relaxation and backwashing on fouling in ultrafiltration were investigated using full-scale membrane bioreactors (MBRs) which operated at a constant flux of 30 LMH. This paper also estimated the feasibility of using intermittent aeration strategies for minimizing the hydraulic resistance to filtration in comparison with the continuous aeration for running MBRs. Multiple cycles of filtration (14.5 min each) and relaxation (0.5 min each) were repeated. Similarly, a backwash was conducted by replacing a relaxation after each filtration cycle for the comparative performance test. The attached cake thickness on the membrane rapidly increased, caused by subsequent no aeration leading to easier combining with gel layer and the formation of heterogeneous layer on the membrane surface. During periodic backwashing, it is expected that gel and thin cake layer might sufficiently be removed by heterogeneous layer. After periodic backwashing, subsequent cake layer formation during time of no aeration was rapid than frequent no aeration, acting as a prefilter and preventing further irreversible fouling. Based on the Pearson correlation analysis, overall period fouling (dTMP/min) and average of all cycles (dTMP/min) were strongly correlated with the on-off period of aeration for operating MBRs.

Effect of Waste Cooking Oil on Durability of High Volume Mineral Admixture Concrete (폐유지류가 혼화재 다량 치환 콘크리트의 내구성에 미치는 영향)

  • Han, Min-Cheol;Woo, Dae-Hoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.173-180
    • /
    • 2013
  • This paper is to investigate an effect of waste cooking oil(WCO) on the engineering properties and durability of high volume admixture concrete. Fly ash with 30% and blast furnace slag with 60% were incorporated in OPC to fabricate high volume admixture concrete with 0.5 of W/B. Emulsified refining cooking oil(ERCO) was made by mixing WCO and emulsifying agent to improve fluidity. ERCO was replaced by cement from 0.25 to 1.0%. As results, the increase of ERCO resulted in decrease of slump and air contents. For compressive strength, the use of ERCO led to decrease the compressive strength at 28 days, while it had similar strength or much higher strength than plain concrete at 180 days. Resistance to carbonation and chloride penetration was improved with the increase of ERCO contents due to decreased pore distribution by saponification between ERCO and concrete, while freeze-thaw resistance was degraded due to air loss.

Study on Vacuum Pump Capacity with Leakage of Tube Structure (튜브구조물의 누설을 포함한 진공 펌프 용량에 관한 연구)

  • Nam, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1157-1161
    • /
    • 2011
  • Parametric study has been conducted to calculate the capacity of vacuum pump system that will be used to maintain the pressure of the tube system under atmosphere level. Recently many railroad researchers pay attention to the tube train system as one of the super high speed transportation system. To achieve the ultra super high speed, the inside of tube system should be maintained the low pressure level. In the low pressure environment, it is well known that air resistance of train is drastically decreased. Vacuum pump system will be used to make the low pressure level of tube system, exhaust the leakage air and supplement additional vacuum pumping. Qualitative and quantitative study has been conducted to review the effects of major parameters concerned with the capacity of vacuum pump system. As a results of these studies, we get the lump capacity of vacuum pump for various parameters. These results can be used to analyse the effects of the reduction of air resistance.

  • PDF

Experimental Study of Polymer Electrolyte Membrane Fuel Cell Performance Under Low Operating Temperatures (상온 작동 환경하에서의 고분자 전해질막 연료전지의 성능에 대한 실험적 연구)

  • Cha, Dowon;Kim, Bosung;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.8
    • /
    • pp.687-693
    • /
    • 2014
  • In this study, the performance characteristics of a polymer electrolyte membrane fuel cell (PEMFC) were investigated at low operating temperatures under steady-state and dynamic conditions. The performance of the PEMFC was analyzed according to the external humidifying rate and air stoichiometry. The ohmic resistance was also investigated using EIS tests. At the operating temperature of $35^{\circ}C$, voltage fluctuation occurred to a greater degree compared to that at $45^{\circ}C$. Therefore, it was found that the air stoichiometry should be higher than 2.5 for the stable operation of the fuel cell. In addition, the relative humidity of the reactant gases should be higher than 60 to reduce the ohmic resistance.

Development of Racing Track Cycle for Elite Players Considered Stiffness and Aerodynamic Effects (공기저항 및 강성을 고려한 선수용 자전거 프레임 설계)

  • Kim, Taekyun;Lim, Woochul;Lee, Tae Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1077-1082
    • /
    • 2013
  • To improve cycling performance, the power output of the rider and the sources of resistance (e.g., air resistance, frame stiffness, and cycle mass) must be considered. From a mechanical viewpoint, we consider how the bike frame performance can be increased while decreasing the resistance. First, to improve the competitive ability of a racing track cycle, we should consider the stiffness of the bike frame including the pedal loading and aerodynamic effects when riding. Therefore, we obtained the cross-sectional area of each part of the bike frame and then aimed to minimize the drag force through an aerodynamic parametric study. In addition, the frame should remain safe under the loading applied by the rider. Under the guidelines of the UCI (union Cycliste Internationale) regulations, the bike frame has been evaluated under the proposed loading condition, and we developed a racing track cycle for elite cyclists.