• Title/Summary/Keyword: 공기의 저항

Search Result 497, Processing Time 0.025 seconds

Study of Gas-turbine Cranking Model using the Coast Down Experimental Results (Coast Down 시험데이터를 이용한 가스터빈엔진 시동모델 연구)

  • Kim, Sun Je;Kim, Yeong Ryeon;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.18-24
    • /
    • 2017
  • Appropriate selection of the starter is essential for successful starting of the gas-turbine engine. Thus, aerodynamic drag during starting phase should be analyzed to assess the feasibility of the starter. In this paper, aerodynamic drag is modeled based on the speed profile from the engine coast down test, and it is scaled with respect to the target engine by comparing the compressor load. Afterward, the govern equation of the starting phase is developed with the torque model of the starter, and the design scheme to select the feasible starter will be finally suggested. The proposed model of starting phase will be useful to perform a preliminary design of the starting system of the gas-turbine engine.

Antibiotic Susceptibility to Isolated Bacteria and Fungi from the Indoor-air (실내 공기중에서 세균 및 진균의 분포와 분리균의 항생물질 감수성)

  • 장명웅;장태호;박인달;김광혁
    • Journal of Life Science
    • /
    • v.8 no.5
    • /
    • pp.537-549
    • /
    • 1998
  • This investigation was performed to isloate and identify the total bacteria, Staphylococcus spp. and fungi from the indoor air exposed for 30 minutes on the blood agar plate at the 27 places in a hospital. Antibiotic susceptibility tests of the isolated bacteria were also studied. The mean numbers of total bacteria, Staphylococci spp. and fungi were 26, 17, and 2 in the summer and 19, 8, and 2 in the winter, respectively. Staphylococcus epidermidis was the most common isolated bacteria, and the next was Staphylococcus aureus, Aerococcus spp., Micrococcus spp., and Bacillus spp. from the indoor-air of hospital. Aspergillus spp., Cephalosporum spp., Curvularia spp., penicillium spp., and Phialophora spp. was frequently isolated from the indoor-air of hospital. The 109 strains of isolated Staphylococcus epidermidis sho-wed resistance to tetracycline(45.0%), methicillin(40.2%), erythromycin(31.2%), and kanamycin(24.8%). The 76 strains of isolated Staphylococcus aureus showed resistance to erythromycin(71.7%), methicillin(63.2%), kanamycin (44.7%), tetracycline(39.5%), and ampicillin(32.9). The 67 strains of isolated Aerococcus spp. showed resistance to erythromycin(26.9%), methicillin(25.4%), kanamycin(22%), and tetracycline(22.4%). The 48 strains of isolated Micrococus spp. showed resistance to tetracycline(27.0%), methicillin(22.9%), erythromycin(22.9%), and kanamycin(20.8%).

  • PDF

Aerodynamic Drag Reduction in Cylindrical Model Using DBD Plasma Actuator (DBD 플라즈마 구동기를 이용한 원통모델의 공기저항저감)

  • Lee, Changwook;Sim, Ju-Hyeong;Han, Sunghyun;Yun, Su Hwan;Kim, Taegyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2015
  • Dielectric barrier discharge (DBD) plasma actuator was designed to reduce aerodynamic drag in a cylindrical model and wind tunnel test was performed at various wind velocities. In addition, computational fluid dynamics (CFD) analysis and flow visualization were used to investigate the effect of the plasma on the flow stream in the cylinderical model. At low wind velocity, the plasma actuator had no effects because flow separation did not appear. The aerodynamic drag was reduced by 14% at 14 m/s and by 27% at 17 m/s, respectively. It was confirmed by CFD analysis and flow visualization that the DBD plasma actuator decreased in pressure difference around the cylindrical model, thus decreasing the magnitude of wake vortex.

Durability of Concrete Using Insulation Performance Improvement Materials (단열성능 향상 재료를 사용한 콘크리트의 내구성에 관한 연구)

  • Park, Young-Shin;Kim, Jung-Ho;Kim, Se-Hwan;Kim, Sang-Heon;Jeon, Hyun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.22-29
    • /
    • 2015
  • In this study, we tested to develop and apply structural insulation performance improvement concrete to field, which had compressive strength in 24 MPa and thermal conductivity twice as much as normal concrete. After experiment about slump and air contents, combination product of Plain and calcined diatomite powder showed reduction of slump and air contents and combination product with micro foam cell admixture, we cannot find result of slump and air contents reduction. Unit weight of combination product with insulation performance improvement materials decreased more than that of Plain. In the test of compressive strength, compressive strength of insulation performance improvement concrete decreased more than that of Plain but was content with 24 MPa. thermal conductivity of insulation performance improvement concrete tended to decrease. Freezing and thawing resistance of insulation performance improvement concrete was similar to that of Plain. In carbonation resistance test, combination product with calcined diatomite powder showed the result which was similar to that of Plain. In carbonation resistance test, combination product with micro foam cell admixture showed a increase compared to that of Plain and length variation of combination product generally increased.

A Study on the Improved Ignition Limit with Resistor for Propan-air Mixture Gas (저항을 이용한 프로판-공기 혼합가스의 점화한계 개선에 관한 연구)

  • 이춘하;오종용;옥경재;지승욱;이광식;심광렬
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • This paper describes the minimum ignition limits for propane-air 5.25 Vol.% mixture gases in low voltage inductive circiuts. The improved effects on the ignition limit are studied by parallel safety components(resistors) for propane-air 5.25 Vol.% mixture gas in low voltage inductive circuits. The experimental devices used in this test are the IEC type spark ignition test apparatus. The minimum ignition limits are controlled by the values of current in inductive circuit. Energy supplied from electric source is first accumulated at the inductance, it's extra energy is working as ignition source of the explosive gas. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 330% by composing parallel circuits between inductance and resistor as compared with disconnecting inductance with the safety components. The more values of inductance increase the higher improved effects of ignition limit rise. The less values of resistor the higher improved effects of ignition limit rise. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in dangerous areas but also for datum for its equipment tests.

Numerical Study for Air-Side Flow Characteristics of Fin-Tube Heat Exchangers with Oval-Tube (타원관형 핀-관 열교환기의 공기측 열유동특성에 대한 수치해석)

  • 김승택;최윤호;김형택
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.166-175
    • /
    • 2001
  • 핀-관 열교환기의 효율을 증대시키기 위하여는 열저항을 결정하는데 있어서 중요한 역할을 하는 공기측 열전달 특성의 향상이 필요하다. 본 연구에서는 슬릿핀과 같은 핀 형상의 개선으로 인한 높은 압력손실을 감소시키기 위하여 타원관형 열교환기를 고려하였으며 이를 자체 개발한 3차원 비압축성 Navier-Stokes 코드를 이용하여 공기측 성능을 해석하였다. 이 코드는 시간항에 스칼라 내재적 근사분해법(scalar implicit approximate factorization)절차, 공간항에 유한체적법과 2차의 풍상차분법을 사용한다. 핀 형상이 평판핀인 타원관에 대하여 세장비가 0.3, 0.5, 0.75인 경우와 핀 형상이 슬릿핀이고 세장비가 0.5인 타원관에 대하여 공기측 유동을 해석하였으며 이를 원관의 성능과 비교하였다. 평판핀의 경우, 압력강하량은 원관과 비교하여 세장비가 작아질수록 감소하는 것을 볼 수 있었으며, 열전달 계수는 고려한 유입속도 범위에서 원관을 기준으로 약 5%이하의 변화로 거의 동일하게 유지되는 것을 볼 수 있었다. 슬릿핀의 경우 역시 문제되는 높은 압력강하량은 타원관을 도입함으로써 효과적으로 낮출 수 있음을 볼 수 있었다.

  • PDF

공기간극이 소방보호복의 열보호성능에 미치는 영향

  • Bang, Yeong-Jun;Lee, Jun-Gyeong;Sin, Hwan-Jun;Lee, Gwan-Geun;Yun, Chang-Sik;Bang, Chang-Hun;Gwon, Jeong-Suk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.57-58
    • /
    • 2013
  • 소방보호복은 고열유속에 의한 화상방지를 위해 3층 이상의 복합소재로 구성되어 있으며, 각 소재 사이는 공기 간극이 존재한다. 화재에 의한 고열유속 노출 시 공기 간극 내에서의 열전달은 대류와 복사에 의해 주로 발생하며, 그로 인해 간극의 크기에 따라서 비선형 특징의 열 저항 크기를 갖게 된다. 그러므로 본 연구에서는 보호복 소재 사이의 여러 가지 공기 간극에 대한 보호복의 열 보호성능을 자세히 파악하기 위한 실험을 수행하였다.

  • PDF

Numerical Modeling for Air-Side Flow Characteristics of Fin-TUbe Heat Exchangers for Air-Conditioning Applications (공조용 핀-관 열교환기의 공기측 열유동특성에 대한 수치모사)

  • 김승택;최윤호
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.309-318
    • /
    • 2000
  • 핀-관 열교환기의 효율을 증대시키기 위하여는 열저항을 결정하는 데 있어서 중요한 역할을 하는 공기측 열전달 특성의 향상이 필요하다. 본 연구에서는 핀-관 열교환기의 공리측 성능을 해석하기 위해서 3차원 비압축성 Navier-Stokes 코드를 개발하였으며 이 코드는 시간항에 스칼라 내재적 근사분해법(scalar implicit approximate factorization)절차, 공간항에 유한체적법과 2차의 풍상차분법(upwind differencing)을 사용한다. 서로 다른 3개의 핀형상(평판핀, 슬릿핀, 파형핀)을 고려하였고 이들의 유동 및 열전달 특성을 연구하였다.

  • PDF

Distribution of HF Concentration Around Source (배출원 주변지역의 HF 농도 분포)

  • 서성규;이선원;황원준;문정선
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.348-349
    • /
    • 2000
  • HF는 주로 음료수와 식수에 의해 폭로되며, 작업자의 경우는 공장 작업과정에서 공기 흡입과 피부 접촉으로 폭로된다. 단기적인 흡입에 의한 폭로는 폐수종 및 자극 등을 주며, 눈과 피부에 직접 폭로시에는 화상과 자극을 준다. 장기간의 폭로는 주로 음료수와 음식에 의해 폭로되며, 공기에 의한 폭로는 코, 인후 및 기관지에 충혈 및 자극을 주고(U. S. EPA, 1989; U. S. EPA, 1993), 식물의 경우에는 잎의 끝이나 가장자리의 변색, 발육 부진 및 병에 대한 저항성 약화 등에 영향을 미치는 것으로 알려져 있다(Cao, 1998). (중략)

  • PDF

The Effects of Silica in Polymeric Membrane On Gas Transport (고분자중 실리카가 기체투과에 미치는 영향)

  • 송병준;김건중;남세종
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.44-45
    • /
    • 1998
  • 1. 서론 : 공기의 산소/질소 분리용 고분자막은 높은 선택도와 높은 투과도를 동시에 요구한다. 이 두가지 조건을 만족시키는 새로운 소재 개발과 기존의 고분자물질을 수식하는 연구가 진행되고 있으나 trade-off 현상으로 인하여 선택도가 증가되면 투과계수가 감소되고, 투과계수가 증가되면 선택도가 감소되는 경향이 있다. 다공성 지지체의 표면에 selective thin layer를 coating한 복합막은 투과저항을 줄여 투과속도는 증가시킬 수 있으나 선택도는 고분자 고유의 80%정도까지 감소되는 것으로 알려져 있다. (생략)

  • PDF