• Title/Summary/Keyword: 공기의 압축성

Search Result 389, Processing Time 0.024 seconds

Development of Compressible Three Phases Flow Simulator Based on Fractional Flow Approach (압축성을 고려한 분율 흐름 접근 방식에 근거한 삼상흐름모델 개발)

  • Suk, Hee-Jun;Ko, Kyung-Seok;Yeh, Gour-Tsyh
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.731-746
    • /
    • 2008
  • Most multiphase flow simulators following fractional flow approach assume incompressibility of fluid and matrix or consider only two phase flow (water and air, water and NAPL). However, in this study, mathematical governing equations were developed for fully compressible three-phase flow using fractional flow based approach. Also, fully compressible multiphase flow simulator (CMPS) considering compressibilities of matrix and fluid was developed using the mathematical governing equations. In order to verify CMPS, the CMPS were compared with analytical solution and the existing multiphase flow simulator, MPS, which had been developed for simulating incompressible multiphase flow (Suk and Yeh 2007; Suk and Yeh 2008). According to the results, solutions of CMPS and MPS and analytical solutions are well matched each other. Thus, it is found that CMPS has the capability of simulating compressible three phase flow phenomena assuming compressibilities of fluids and matrix.

블라인드 장착에 따른 실내 공기 순환 연구

  • Nam, Do-U;Hwang, Jae-Min
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.625-627
    • /
    • 2016
  • 본 논문은 EDISON CFD의 전처리기, eMEGA를 이용하여 격자를 생성하고, 2차원 정렬 격자 기반 비압축성 해석자를 이용하여 유동해석을 진행한 뒤 후처리기, eDAVA를 통해 유동선을 그려 블라인드 장착에 따른 실내 공기 순환에 대한 연구 내용을 담고 있다. 본 연구는 시중에 판매중인 사생활 보호용 블라인드를 포함, 여러 블라인드의 장착 여부에 따라 실내 내부 공기 순환의 양상을 확인하고 실제로 블라인드 장착 시 실내환기에 어떤 영향을 주는지 유동 선을 통해 확인해 보았다. 블라인드 미장착시, 실내 전체적으로 공기가 고루 순환되는 모습을 보였으며, 블라인드 장착 시 대체로 블라인드 형태에 따라 유동이 이동하는 것을 볼 수 있었다. 본 연구는 사생활 보호와 환기 효율성의 관점에서의 소비자 선택권에 영향을 미치는 효과를 가져 올 것으로 보인다.

  • PDF

Numerical Study on the Super Sonic Phenomenon of Compressed Air according to the Flow Path Conditions (유로조건에 따른 압축공기 초음속 유동 현상의 해석 연구)

  • Kim, Seung Mo;Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.470-476
    • /
    • 2019
  • The braking force for a train is generally provided by compressed air. The pressure valve system that is used to apply appropriate braking forces to trains has a complex flow circuit. It is possible to make a channel shape that can increase the flow efficiency by 3D printing. There are restrictions on the flow shape design when using general machining. Therefore, in this study, the compressed air flow was analyzed in a pressure valve system by comparing flow paths made with conventional manufacturing methods and 3D printing. An analysis was done to examine the curvature magnitude of the flow path, the diameter of the flow path, the magnitude of the inlet and reservoir pressure, and the initial temperature of the compressed air when the flow direction changes. The minimization of pressure loss and the uniformity of the flow characteristics influenced the braking efficiency. The curvilinear flow path made through 3D printing was advantageous for improving the braking efficiency compared to the rectangular shape manufactured by general machining.

Study for High Efficiency Heat Pump System Commercialization with Air Heat Source (고효율 공기열원 히트펌프시스템 실용화 연구)

  • Han, Jang-Min;Kim, Young-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.405-408
    • /
    • 2009
  • 공기열원 히트펌프시스템의 문제점, 즉 열효율, 안정성, 착상에 대한 현황을 파악하고 이를 해결하기 위한 연구를 수행하였다. 열효율과 안정성을 위해 기존 시스템을 보완한 8행정 냉매사이클시스템 개발과 제어시스템의 개발을 통해 히트펌프 시스템의 효율을 2배 정도 증가시키고, 안정성을 높이며, 착상 문제를 최소화할 수 있도록 하였다. 개발된 공기열원 히트펌프시스템의 COP는 평균 5정도이고, 안정적으로 운용되는 외부 온도는 $-10^{\circ}C$에서 $55^{\circ}C$까지이다. 토출되는 온수의 온도는 $50{\sim}60^{\circ}C$정도이다. 평균 제상시간은 1분 이내이다. 앞으로 개발해야 할 문제는 외부 온도 $-10^{\circ}C$ 이하지역에서 보조열원 없이 난방을 할 수 있고 친환경 냉매를 사용하며 COP가 7이상인 고효율 히트펌프시스템를 실용화하는 것이다.

  • PDF

Simulation of Pressure Oscillation in Water Caused by the Compressibility of Entrapped Air in Dam Break Flow (댐 붕괴 유동에서 갇힌 공기의 압축성에 의한 물의 압력 진동 모사)

  • Shin, Sangmook
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.1
    • /
    • pp.56-65
    • /
    • 2018
  • Pressure oscillation caused by the compressibility of entrapped air in dam break flow is analyzed using an open source code, which is a two-phase compressible code for non-isothermal immiscible fluids. Since compressible flows are computed based on a pressure-based method, the code can handle the equation of state of barotropic fluid, which is virtually incompressible. The computed time variation of pressure is compared with other experimental and computational results. The present result shows good agreements with other results until the air is entrapped. As the entrapped air bubbles pulsate, pressure oscillations are predicted and the pressure oscillations damp out quickly. Although the compressibility parameter of water has been varied for a wide range, it has no effects on the computed results, because the present equation of state for water is so close to that of incompressible fluid. Grid independency test for computed time variation of pressure shows that all results predict similar period of pressure oscillation and quick damping out of the oscillation, even though the amplitude of pressure oscillation is sensitive to the velocity field at the moment of the entrapping. It is observed that as pressure inside the entrapped air changes quickly, the pressure field in the neighboring water adjusts instantly, because the sound of speed is much higher in water. It is confirmed that the period of pressure oscillation is dominated by the added mass of neighboring water. It is found that the temperature oscillation of the entrapped air is critical to the quick damping out of the oscillations, due to the fact that the time averaged temperature inside the entrapped air is higher than that of surrounding water, which is almost constant.

Static Analysis of Gas Bearing with Ultra Low Clearance by the Direct Numerical Solution Method (극소 공기막을 갖는 공기베어링의 직접수치해법을 이용한 정적해석)

  • Park, Sang-Sin;Chang, In-Bae;Hwang, Pyung;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.120-126
    • /
    • 1991
  • An expanded scheme of a direct numerical solution method for solving the Navier-Stokes equation considering the modified boundary conditions for gas lubrication with ultra low clearance at high .LAMBDA. region is presented. Many examples are calculated by this scheme and their results are compared to the previous solutions using P$^{2}$H$^{[-992]}$ . This scheme has the advantages of fast calculation time and stable convergence in high .LAMBDA. region, and gives very good results in the case of fluid film thickness discontinuity.

The Effect of the Integration Methods of Gas Turbine and Air Separation Unit on IGCC Plant Performance (가스터빈과 산소분리공정의 연계 방법에 따른 IGCC 플랜트 성능영향 분석)

  • 서석빈;김종진;조상기;이윤경;안달홍
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.533-539
    • /
    • 1999
  • Integration methods of a Gas Turbine and a Air Separation Unit have a potential to improve plant performance and cost of IFCC. Several studies on those integrations schemes were carried out. Then some of the methods were accually in commercial plants. Thus paper reviewed the integration schemes of a Gas Turbine and a Air Separation Unit. In order to compare the plant performance of IGCC with each scheme, simulation model was developed for IGCC power cycle with Texaco Quench gasification process. The simulation results showed that the thermal efficiency of the plant was appeared to be the best when all of the air consumption required for Air Separation Unit was supplied from the Gas Turbine and the net plant power output was maximized when 75% of the total ASU an requirement was supplied from Gas Turbine.

  • PDF

Air Compressibility Effect in CFD-based Water Impact Analysis (CFD 기반 유체충격 해석에서 공기 압축성 효과)

  • Tran, Huu Phi;Ahn, Hyung-Taek
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.6
    • /
    • pp.581-591
    • /
    • 2011
  • This paper describes the air compressibility effect in the CFD simulation of water impact load prediction. In order to consider the air compressibility effect, two sets of governing equations are employed, namely the incompressible Navier-stokes equations and compressible Navier-Stokes equations that describe general compressible gas flow. In order to describe violent motion of free surface, volume-of-fluid method is utilized. The role of air compressibility is presented by the comparative study of water impact load obtained from two different air models, i.e. the compressible and incompressible air. For both cases, water is considered as incompressible media. Compressible air model shows oscillatory behavior of pressure on the solid surface that may attribute to the air-cushion effect. Incompressible air model showed no such oscillatory behavior in the pressure history. This study also showed that the CFD simulation can capture the formation of air pockets enclosed by water and solid surface, which may be the location where the air compressibility effect is dominant.

The effect of air integration on IGCC performance (공기연계시 IGCC 플랜트 성능 영향 분석)

  • 서석빈;김종진;조상기;이윤경
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.45-48
    • /
    • 1999
  • 석탄가스화복합발전(Integrated Gasification Combined Cycle)기술은 우수한 환경성능과 열성능을 지니고 있어 장래 미분탄화력을 대신할 수 있는 대체기술로서 각광을 받고 있다. IGCC는 석탄가스화, 정제, 복합발전계통 및 공기분리계통 등 그 구성요소가 복잡하여 이들간의 시스템 최적화 정도에 따라 경제성 및 플랜트 성능이 크게 좌우된다. 최근에 가스터빈과 공기분리설비(Air Separation Unit)를 연계시켜 IGCC플랜트 성능을 향상시키는 연구가 다수 진행되었다[1],[2],[3]. 본 연구에서는 가스터빈과 ASU 간의 연계시 공기추출량을 결정하는 인자들을 검토하고 Texaco quench 가스화공정을 채용한 IGCC 플랜트에 대해 GatecCyle code등 상용코드를 이용하여 모델링하고 가스터빈 압축기 공기추출량에 따른 IGCC 플랜트 성능을 분석하였다. 본 연구 결과를 통하여 대상 IGCC 플랜트의 적정 공기추출량을 결정하고 플랜트 성능을 계산하였다. 본 연구 결과는 전력연구원에서 수행중인 300MW급 IGCC 예비기본설계에 활용될 것이다.(중략)

  • PDF

Hydraulic stability evaluation for deep tunnel on continuous precipitation (연속강우에 대한 대심도 터널의 수리적 안정성 평가)

  • Oh, Jun Oh;Park, Jae Hyeon;Park, Chang Keun;Jun, Sang Mi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.99-99
    • /
    • 2016
  • 최근 홍수의 특성과 피해 양상은 과거와는 다르게 변화하고 있으며, 급격한 도시화로 인하여 기존 하천유역의 저류 능력이 감소하였는데 이러한 한계를 극복하기 위하여 이미 외국에서는 대심도 터널을 활용한 홍수재해 관리방안이 오래전부터 활용되어 왔다. 본 연구에서는 현재 서울시에 건설중인 '신월 빗물저류배수시설' 연속강우 시 대심도 터널의 수리적 안정성 평가와 운영방안 수립을 위한 수리모형실험을 실시하였다. 모형은 Froude 상사법칙을 사용하여 원형의 1/50크기로 제작하였다. 모형의 전체 저류 가능량은 모형기준 $2.78m^3$ (원형 $347,778m^3$)이며, 터널 내 잔류수는 전체 저류 가능량의 0 ~ 100%까지 10%씩 변화시켜 실험 CASE를 선정하였다. 각 실험CASE별 수직 유입구 안정성 평가를 실시한 결과 터널 내 잔류수가 10%~80%까지 존재 할 때는 저지수직구1에서의 압축공기 폭발현상으로 인한 월류현상이 발생하였으며, 10%~40%까지는 저지수직구2에서 월류현상이 발생하였다. 하지만 고지수직구에서는 모든 CASE에서의 공기폭발 현상 및 월류현상이 발생하지 않아 유입성능 및 공기배출 성능이 충분히 발휘되고 있는 것으로 분석되었다. 또한 저지수직구1에서의 월류현상 발생 시점은 5분55초에서 3분42초까지 빨라졌으며 저지수직구2에서의 월류현상 발생 시점은 5분57초에서 4분57초로 빨라졌다. 이는 터널 내 잔류수량이 증가할수록 터널 내 만관시점이 빨라져 발생하며, 저지수직구1,2에서의 압축공기 폭발현상 및 월류 현상은 터널 내에서 발생한 반사파의 영향으로 판단된다. 차후 터널 내 반사파 발생에 대한 연구가 추가적으로 진행되어야 할 것이다.

  • PDF