• Title/Summary/Keyword: 공기셀

Search Result 100, Processing Time 0.032 seconds

Technology of Minimized Damage during Loading of a Thin Wafer (박판 웨이퍼의 적재 시 손상 최소화 기술)

  • Lee, Jong Hang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.321-326
    • /
    • 2021
  • This paper presents a technique to minimize damaged wafers during loading. A thin wafer used in solar cells and semiconductors can be damaged easily. This makes it difficult to separate the wafer due to surface tension between the loaded wafers. A technique for minimizing damaged wafers is to supply compressed air to the wafer and simultaneously apply a small horizontal movement mechanism. The main experimental factors used in this study were the supply speed of wafers, the nozzle pressure of the compressed air, and the suction time of a vacuum head. A higher supply speed of the wafer under the same nozzle pressure and lower nozzle pressure under the same supply speed resulted in a higher failure rate. Furthermore, the damage rate, according to the wafer supply speed, was unaffected by the suction time to grip a wafer. The optimal experiment conditions within the experimental range of this study are the wafer supply speed of 600 ea/hr, nozzle air pressure of 0.55 MPa, and suction time of 0.9 sec at the vacuum head. In addition, the technology improved by the repeatability performance tests can minimize the damaged wafer rate.

Soil Water Characteristic Curve Using Volumetric Pressure Plate Extractor Incorporated with TDR System (TDR 측정시스템이 도입된 압력판 추출 시험기를 이용한 흙-함수특성곡선 연구)

  • Jung, Young-Seok;Sa, Hee-Dong;Kang, Seonghun;Oh, Se-Boong;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.8
    • /
    • pp.17-28
    • /
    • 2015
  • The purpose of this study is to measure the volumetric water content of unsaturated soils during drying and wetting process by using volumetric pressure plate extractor (VPPE) incorporated with time domain reflectometry (TDR). The VPPE consists of a pressure cell, a pressure regulator, a burette system and a TDR probe. Two samples with different initial void ratios were prepared in the pressure cell, and the air pressure at the range of 0.1 kPa - 50 kPa was applied to adjust the matric suction by the pressure regulator. The burette system was used to measure the volumetric water content change of the sample according to the matric suction. In addition, the TDR probe, installed in the cell, was used to evaluate the dielectric constant from the reflected signal of the electromagnetic wave at the probe. The volumetric water content of specimen was estimated by the empirical equation between the volumetric water content and dielectric constant, which was calibrated with the Jumunjin sand. The test results show that the volumetric water content calculated by TDR probe is strongly correlated to the measured value by burette system. The hysteresis occurs during drying and wetting process. Furthermore, the degree of hysteresis reduces in the repeated process. This study suggests that TDR may be effectively used to evaluate the water content soil for the determination of water characteristic curve of unsaturated soils.

Dual Solutions for Steady Natural Convection of Air in Horizontal Cylindrical Annulus (수평 원주형 환형내에서의 정상상태의 공기의 자연대류에 대한 이중해)

  • Yu, Ju-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2981-2990
    • /
    • 1996
  • Dual solutions for steady natural convection of air between two horizontal concentric cylinders are numerically investigated in the range of $D_i$/TEX>/L(=diameter of inner cylinder/gap width)$\leq$10. It is found that, when the Rayleigh number based on the gap width exceeds a certain critical value, a new flow pattern forming two counter-rotating eddies in the half of the annulus can be realized, which is different from the crescent-shaped flow commonly observed. In the new flow pattern, the fluid near the top of the hot inner cylinder moves downward. This solution is found for D$_{i}$/L.geq.0.3, but not for$D_i$/TEX>/L$\leq$0.2. As $D_i$/TEX>/L increase, the critical Rayleigh number is decreased, and tends to a finite limit.t.

The behavior of corrosion potential in the mortar-embedded (부식된 철근을 사용한 모르타르의 환경에 따른 부식전위의 거동)

  • 이상호;한정섭;권순석
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.103-108
    • /
    • 1996
  • To syudy the change of prtential in the mortar-embedded precorroded rebar, a half cell method was adapted. The rebar was corroded by the salt spray and then the rebar embedded in the mortar. A saturated copper sulfate feference electrode was used. The corrosion potential of the rebar in the mortar specimen cured in air was increased, whereas that of the rebar cured in water was decreased with aging. The corrosion potential of the rebar in the mortar was decreased with corroded time by the salt spray. As the mortar thickness covered the rebar was increased, the corrosion potential of the rebar in the mortar was increased.

  • PDF

Dual Natural-Convective Flows of Air in a Horizontal Annulus with a Constant Heat Flux Cylinder (일정 열유속 실린더를 갖는 수평 환형 공간에서의 공기의 이중 자연대류 유동)

  • Yoo Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • Natural convection in a horizontal annulus with the inner cylinder heated by the application of a constant heat flux and the isothermally cooled outer cylinder is considered, and the transition of flows and the bifurcation phenomenon are numerically investigated for air with Pr=0.7. The zero initial condition always induces a crescent-sheped eddy flow. A bicellular flow in which the fluid descends along the vertical central plane of the annulus can be obtained at high Rayleigh number by introducing artificial numerical disturbances. Dual solutions are found above a certain critical Rayleigh number. Hysteresis phenomena have not been observed.

  • PDF

Study on High Degree of Efficiency Chemical Reactor for Air Purification Using the Glow Discharge (글로우 방전을 이용한 고효율 공기 정화용 화학 반응기의 특성관찰에 관한 연구)

  • Kim, Gi-Ho;Bu, Min-Ho;Lee, Sang-Cheon
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.1
    • /
    • pp.14-22
    • /
    • 2006
  • the basic model of chemical reactor using glow discharge, we used cathode discharge cell with vacant cavity in the middle. Currently glow discharge is widely studied as a radiation source or atomization device in atomic spectroscopy and remarkable technological achievements are made through the graft with other analysis devices such as microanalysis and steel analysis.1 Additionally, as the characteristics of basic glow discharge and radiation have been reviewed many times, those results could be used in this experiment.2-3 In 1993, an article regarding the treatment of poisonous gas in the air using low temperature plasma was published. According to this article, if DC Glow Discharge is used under continuous atmospheric flow, poisonous gases such as SO2 and NO can be removed.4 Based on those findings, we designed highly efficient reactor where stable air plasma is composed and all air flow pass the negative glow area passing through the tube. It was observed that the cathode tube type glow discharge developed in this study would be economical, easy to use and could be used as radiation source as well.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

밀폐형 압축기의 소음진동에 대한 연구 예와 시급한 연구과제에 관하여

  • 김종혁
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.17-24
    • /
    • 1998
  • 압축기의 종류는 크게 dynamic type과 positive displacement type으로 우선 나눌 수 있다. 전자는 제트엔진에 사용되는 압축기에서 보는 바와 같이 기체의 속도를 변화시켜 동압을 정압으로 바꾸어 압력을 얻는 경우이다. 후자는 기체를 둘러싼 체적을 줄여서 압력을 얻는데 가전제품에 쓰이는 냉각용 압축기의 대부분의 종류가 이에 해당된다. 압축 기체의 종류에 따라 공기 압축기, 가스 압축기, 냉각용 압축기로도 나눌 수 있겠다. 냉각용 압축기는 다시 여러 가지 방법으로 분류할 수 있겠지만, 구동 모타의 용량이나 냉각 용량에 따라, 대형, 소형으로 분류하거나, 압축기를 둘러싼 셀의 구조에 따라 밀폐형과 반 밀폐형으로 나눌 수 있다. 밀폐형은 냉매를 반 영구적으로 보충할 필요가 없도록 용접형 셀을 가진 구조로 압축기를 다시 열어서 보수할 수가 없다. 냉장고나 냉방기 같은 가전 제품에 쓰이는 압축기는 대부분 소형 밀폐형이 되겠다. 산업용의 중,대형 압축기는 보수의 목적으로, 자동차 냉방용 압축기는 동력이 엔진축에서 공급되는 구조 상의 이유로 반 밀폐형이 채택된다. 보수가 사실상 불가능한 밀폐형의 구조 상 소형 냉장용 압축기는 거의 무한 수명을 감안한 설계를 요하게 되고, 이것이 압축기의 보수적인 설계 및 개발 성향에 어느 정도 영향을 주었다고 볼 수 있다. 이런 소형 밀폐형 압축기(positive displacement, fractional horsepower, hermetic compressor)에 관한 연구의 소개가 이 글의 주 관심이 되겠다. 압력을 얻기 위해 체적을 변화시키는 mechanism도 여러 가지가 있는 바, 왕복동식 피스톤(reciprocating piston) 압축기가 가장 오랫동안 사용되어 온 구조이다. 회전식으로 압축을 얻는 방식으로는 로타리 피스톤식, 스크류식, 스크롤식 압축기가 있다. 로타리 피스톤(rotary piston)식 압축기는 약 20여년 전 부터 냉방용 압축기에서부터 널리 쓰이게 되었다. 약 10여년전부터 상용화 된 스크롤(scroll) 형 압축기도 현재 상대적으로 용량이 큰 가정용 냉방기를 중심으로 많이 쓰이고 있다. 스크류형 압축기는 보통 중대형 상업용에 주로 쓰인다.

  • PDF

Performance Evaluation of Paving Blocks Based Ambient Temperature Reduction Using a Climatic Environment Chamber (기후환경챔버를 활용한 블록의 공기온도 저감 성능평가)

  • Ko, Jong Hwan;Park, Dae Geun;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.187-192
    • /
    • 2017
  • This study evaluated the reduction performance of ambient temperature and the amount of evaporation that takes place depends on the temperature difference of paving blocks which are used in the sidewalk, roadway, parking lot, park, plaza, and etc. The water-retentive block of the LID (Low Impact Development) practice was compared with the conventional concrete block. For the quantitative performance evaluation, experiments were performed in a climatic environment chamber capable of controlling the climatic environment (solar radiation, temperature, humidity, rainfall, and snowfall). The method for performance evaluation was proposed using temperature, humidity, and ambient air of paving blocks which changes according to the solar radiation and the wind speed after the rainfall. As a result, the evaporation amount of the water-retentive block was 2.6 times higher than that of the concrete block, the surface temperature of water-retentive block was $10^{\circ}C$ lower than the concrete block, and the air temperature of water-retentive block was $4.6^{\circ}C$ lower than the concrete block. Therefore, it is analyzed that the water-retentive block with a large amount of evaporation is more effective in reducing the urban heat island phenomenon as compared with the concrete block.