• Title/Summary/Keyword: 공기부상

Search Result 164, Processing Time 0.031 seconds

Non-Contact Level on Air Levitation Table with Porous Chamber Array (다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구)

  • Kim, Joon Hyun;Jeong, Young Suk;Lee, Tae Geol;Kim, Tae Hoon;Jung, Hyo Jae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

Solid Separation and Flotation Characteristics of Livestock Wastewater Using DAF Process (DAF 공정을 이용한 축산폐수의 고형물 분리와 부상특성)

  • Kang, Byong-Jun;Yoo, Seung-Joon;Lee, Se-il;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.359-366
    • /
    • 2008
  • The series of experiments under the various conditions were carried out to evaluate the feasibility of dissolved air flotation (DAF) as an alternative of conventional gravity sedimentation (CGS) and to investigate the decrease of the loadings following to biological wastewater treatment processes in livestock wastewater system. On the basis of the experiment result between CGS and DAF processes, for the other water quality criteria as well as suspended solid the removal efficiency of DAF process was about 20~25 % better than CGS process on average. In addition, the particle removal efficiency of DAF process became higher in proportion as the increase of air to solid (A/S) ratio and the general wastewater treatment efficiency of DAF process was enough to meet the requirement of loading decrease to following biological process even at low A/S ratio range. Though DAF process is widely known as an solid separation unit, there was not the notable relationship between particle separation efficiency and several pollutant removal efficiencies like $COD_{Cr}$ and nutrients (T-N, T-P). Assume that the $COD_{Cr}$ was removed as the fraction of particle separation in this experiment, the removal efficiency of T-N and T-P were sensitive to removal efficiency of $COD_{Cr}$, especially.

Evaluation of Floc Formation Conditions for Increasing Flotation Velocity in DAF Process (DAF 공정에서 부상속도 향상을 위한 플럭형성 조건 평가)

  • Kwon, Soon-Buhm;Min, Jin-Hee;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.245-255
    • /
    • 2006
  • Dissolved air flotation is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In order to enhance the flotation velocity and removal efficiency of flocs in the flotation process, we tried to obtain pretreatment conditions for the optimum DAF process operation by comparing and evaluating features of actual floc formation and flotation velocity etc, according to coagulant types and conditions for flocculation mixing intensity by using PIA, PDA, and FSA. Accordingly, generating big flocs that have low density at low flocculation mixing intensity may reduce treatment efficiency. In addition, generating small flocs at high flocculation mixing intensity makes floc-bubbles smaller, which reduces flotation velocity, In this study, it was found that high flocculation mixing intensity could not remove the remaining micro-particles after flocculation, which had negative effects on treated water quality, Therefore, in order to enhance treatment efficiency in a flotation process, flocculation mixing intensity around $50sec^{-1}$ is effective.

An Experimental Study on Heat Transfer Characteristics of Synthetic Gas($H_2/CO$)Air Premixed Flames in an Impinging Jet Burner - Part 1 : Stretched Lift-off Flames (충돌제트 버너에서 합성가스($H_2/CO$) 공기 예혼합 화염의 열전달 특성에 관한 실험적 연구 - Part 1 : 스트레치된 부상 화염)

  • Kang, Ki-Joong;Jo, Joon-Ik;Lee, Kee-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.453-456
    • /
    • 2011
  • An experimental investigation of the heat transfer characteristics of stretched premixed flames using Synthetic gas has been performed. Hydrogen and carbon mon-oxide which could be extracted from coal gasification process are the main fuel of synthetic-gas. Heat flux at the stagnation point was increased as global strainrate was increased, then the heat flux was decreased when a global strainrate reached a sudden point. Heat flux at the stagnation point is also affected by nozzle to impingement distance. Heat flux was increased as nozzle to impingement place distance was increased. This study is a foundation study of practical use of secondary gases from coals.

  • PDF

Cause of Break-up and Flotation Characteristics for Sludge from DAF Process (DAF 공정에서 발생한 슬러지의 Break-up 원인과 부상 특성)

  • Yoo, Young-Hoon;Moon, Yong-Taik;Kim, Seong-Jin;Lee, Kwang-Joon;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.527-536
    • /
    • 2010
  • Although the bubble-floc agglomerate floated and formed the float layer on the surface of the water in the DAF process, after inducing in the thickening tank a part of the bubble-floc agglomerate come up again to the surface and the other is settled at the bottom of the tank. The bubble-floc agglomerate divided into two group as the scum on the surface and the sludge of the bottom gives rise to operational troubles for the thickening process. In order to find out the cause of break-up and the effective thickening method for sludge from the DAF process, the composition of the bubble-floc agglomerate was investigated and a series of flotation experiments carried out. There was no difference of composition between the scum on the surface and the sludge of the bottom in the thickening tank. The coagulation was not effective to improve the trouble that the bubble-floc agglomerate divided into the scum and the sludge. It was estimated that for the bubble-floc agglomerate of thickening tank the trouble was caused by not the change or the difference of chemical composition but whether the bubble-floc agglomerate hold bubbles. Furthermore, for the effective thickening of sludge from the DAF process, it is required an additional flotation applied the AS ratio depending upon the solid concentration of sludge as the operation parameter.

Effect of Coagulants and Separation Methods on Algal Removal in Water Treatment Process (정수처리에서 응집제 종류와 분리공정이 조류 제거에 미치는 영향)

  • Park, Hung-Suck;Lee, Sang-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.279-289
    • /
    • 2000
  • The objective of this study was to investigate the effect of coagulants and solid-liquid separation methods on algal removal in water treatment processes. Thus characterization of raw water quality in terms of turbidity. UV-254, $KMnO_4$ consumption, chlorophyll-a and correlation analysis of these parameters were conducted. In addition, the effect of commercial Al-based coagulants(Alum. PAC and PACS) on algal removal was studied by turbidity and organic removal, algal species removal, characteristic of pH drop and alkalinity consumption using laboratory jar tests. Organic components including UV-254, $KMnO_4$ consumption, chlorophyll-a in case of algal bloom were highly correlated with turbidity and the correlation coefficients of UV-254, $KMnO_4$ consumption, chlorophyll-a with turbidity were 0.775, 0674 and 0.623, respectively. In coagulation and sedimentation, the Al-based coagulants showed similar efficiency of organic and turbidity removal in low organic($KMnO_4$ consumption below 15mg/l) and low turbidity(below 30NTU). However, PAC and PACS showed better algal removal than alum in high organic concentration($KMnO_4$ consumption above 20mg/l) and high turbidity(above 100NTU) raw water conditions generated by high algal growth, which is considered to be due to the floc settleability. In comparison of sedimentation and flotation after chemical coagulation and flocculation, the removal efficiency of organic and turbidity were higher in case of alum dose with flotation than with sedimentation, while those were better in case or PAC and PACS with sedimentation than with flotation. Thus, Alum with flotation and PAC and PACS with sedimentation is recommended for efficient algal removal. The dominant phytoplankton in raw water were Microcystic and pediastrum simplex and the removal efficiency of algae with sedimentation using alum. PAC and PACS were 27%, 45% and 22% respectively, while those with DAF showed 100% removal of phytoplankton and zooplankton.

  • PDF

Study on the design factor to scale up the zinc/air fuel cell (아연/공기전지의 scale-up을 위한 설계인자 연구)

  • Lee, Hoil;Oh, Taeyoung;Park, Sangmin;Kim, Jungyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.74.2-74.2
    • /
    • 2010
  • 전세계는 $CO_2$ 규제강화와 에너지의 효율적 사용에 대한 사회적, 경제적 요구가 증대되면서 친환경 에너지 설비와 지능형 전력망(smart grid)가 크게 예상되고 있다. 이에 따라 기존 내연기관에 근거한 발전산업 및 자동차 산업은 필연적으로 청정에너지 기반의 전기에너지로 점진적으로 대체될 것으로 판단된다. 따라서, 청정 발전 시스템의 보급 확대와 기존 에너지의 효율적 사용을 위해서 2차전지 기반의 전력저장 기술과 연료전지 기반의 분산발전 기술이 향후 미래에너지 산업의 근간이 되는 중요한 기술들로 부상하게 되었다. 아연/공기전지는 현재는 연료전지 개념의 1차전지에 기술수준이 머물러 있지만 향후 미래에는 기존의 리튬이온전지의 낮은 에너지밀도를 극복할 수 있는 미래 2차전지 기술의 하나로 평가받고 있다. 본 연구에서는 이러한 연료전지 개념의 아연/공기전지에 대하여 기존의 수소연료전지 기반의 분산발전 분야에 적용한다면 약 1/10 이하의 가격으로 조기에 시장진입이 가능할 것으로 판단하여 사전 타당성 연구 및 대면적화를 위한 기초 설계인자 연구를 수행하였다. 연구결과, 소형 단전지부터 약 800cm2까지의 대면적 단전지까지 대면적화를 위한 기초연구를 실시하였으며, 4개의 cell로 구성된 최고출력 90W급 전해질 순환형 미니스택 시스템을 구성하여 발전시스템으로서의 가능성과 문제점 등을 도출하였다. 이러한 시험결과를 바탕으로 25개의 cell로 구성된 약 1kW 급 스택을 설계하여 향후 소형 발전시스템을 제작하고자 하였다.

  • PDF

Wastewater Treatment using Air-lift Biofilm Reactor (공기부상 생물막 반응기를 이용한 산업폐수 처리)

  • 최광수;한기백
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.351-367
    • /
    • 2000
  • Air-lift biofilm reactor should be an admirable process substituting conventional activated sludge process, because of its small area requirement as well as high volumetric loading capacity and stability against loading and chemical shocks. However most of the past research on the performance of ABR was focused on the sewage treatment. This research studied the applicability of ABR to treat high strength wastewater. A bench-scale ABR was operated to treat high strength synthetic wastewater, tannery wastewater and petrochemical wastewater, and its applicability was conclusive In case of synthetic wastewater, ABR showed good performance in which the substarate removal efficiency was higher that 80% even under short HRT(1.4 hr) and high volumetric loading rate(9.3 kgCODcr/$m^3$.day). When ABR was applied to treat tannery wastewater, it was suggested that the maximum volumetric loading rate and F/M ratio should be 7.7kgCODcr/$m^3$.day, 0.76 $day^{-1}$, respectively. And high substrate removal efficiency over than 90 % was observed with 4,000 mgCODcr/L of petrochemical wastewater. Even though effluent concentration was quite high, ABR should be applicable to treat the high strength wastewater, because of its high loading capacity.

  • PDF

Study on Through Paths Inside the Air Pressure Pick-Up Head for Non-Contact Gripper (비접촉식 그리퍼 적용을 위한 공기압 파지식 헤드 내부 관통로 고찰)

  • Kim, Joon-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.563-569
    • /
    • 2012
  • In the semiconductor and display device production processes, the handling of sensitive objects needs new carrying technology. Floating carrying motion is a practical alternative solution for non-contact handling of parts and substrates. This paper presents a study of through paths inside the air pressure pick-up head to generate the floating motion. The air motion by conceptual designed paths inside the head gradually develops positive pressure and vacuum between narrow objects. Positive pressure occurs through the head tip before discharging outside of the head. Negative pressure is developed by evacuating the inside head bottom as result of the radial flow connecting the vertical through-holes. The numerical analysis was done to figure out the stable levitation caused by the two acting forces between surfaces. In comparing with the standard case that the levitation gap gets 0.7-0.9 mm, it confirms the suggested head characteristics to show floating capacity in accordance with the head size, number of through-hole, and locations of through-hole in succession of conceptual design for a prototype.

The Optimal Design of Air Bearing Sliders of Optical Disk Drives by Using Simulated Annealing Technique (SA 기법을 이용한 광디스크 드라이브 공기베어링 슬라이더의 최적설계)

  • Chang, Hyuk;Kim, Hyun-Ki;Kim, Kwang-Sun;Rim, Kyung-Hwa
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1545-1551
    • /
    • 2002
  • The optical storage device has recently experienced significant improvement, especially for the aspects of high capacity and fast transfer rate. However, it is necessary to study a new shape of air bearing surface for the rotary type actuator because the optical storage device has the lower access time than that of HDD (Hard Disk Drives). In this study, we proposed the air bearing shape by using SA (Simulated Annealing) algorithm which is very effective to achieve the global optimum instead of many local optimums. The objective of optimization is to minimize the deviation in flying height from a target value 100nm. In addition, the pitch and roll angle should be maintained within the operation limits.