• 제목/요약/키워드: 공기냉각

검색결과 425건 처리시간 0.027초

18650 리튬-이온 단일 배터리 모듈의 냉각 성능 비교에 관한 실험적 연구(공기 냉각과 PCM 기반 냉각) (Experimental Study of Cooling Performance Comparison of a 18650 Li-ion Unit Battery Module (Air Cooling vs. PCM-based Cooling))

  • 백승수;유시원;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제29권2호
    • /
    • pp.212-218
    • /
    • 2018
  • Li-ion battery system is regarded as one of the most potent power sources for electrified power-trains. For the Li-ion battery system to be widely adopted in automotive applications, the performance, safety, and cycle life issues need to be properly addressed. These issues are closely related to the thermal management of battery system. Especially, the effective cooling module design is the core part for the novel battery thermal management system development. In this paper, an experimental approach was carried out as a basic part of comprehensive battery thermal management research. The main goal of this paper is to present a comparison of two cooling systems (air cooling and phase change material (PCM) based cooling) of the unit 18650 battery module. The temperature rise with different battery discharge rate (c-rate) was mainly investigated and analyzed for two types of battery cooling systems. It is expected that this study can properly contribute to providing basic insights into the design of robust battery thermal management system for vehicular applications.

가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석 (Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System)

  • 박현우;이정수;조건환;조진수
    • 한국항공우주학회지
    • /
    • 제47권12호
    • /
    • pp.881-889
    • /
    • 2019
  • 가스터빈 이차 유로의 프리스월 시스템은 터빈의 효율을 높이고 소재의 수명을 연장하기 위해 설치되는 냉각 장치이다. 본 연구에서는 프리스월 시스템의 설계점을 기준으로 가스터빈 외기 온도와 터빈 부하 변화에 따른 탈설계점 분석을 수행하였다. 탈설계점에서 내부 유동의 특성을 분석하기 위하여 유량계수와 단열계수를 비교하였다. 터빈 부하 증가에 따라 시스템 내부 냉각 공기의 체적 유량이 증가하였고, 단열계수 또한 20% 터빈 부하와 비교하여 100% 터빈 부하에서 30.46% 상승하였다. 외기 온도가 증가할수록 질량 유량과 냉각 공기의 밀도는 감소하였지만 체적 유량은 상승하였으며, 결과적으로 프리스월 시스템 내부의 냉각 성능은 향상되었다. 프리스월 시스템 출구에서 -20℃ 외기 온도와 비교하여 55℃ 외기 온도의 단열계수는 14.82% 향상되었다.

간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구 (Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.743-749
    • /
    • 2015
  • 본 연구의 목적은 간접식 증발냉각 장치의 성능을 예측하고, 장치를 공기조화기의 배기열 회수에 적용하였을 경우의 에너지 절약효과를 분석하는 것이다. 플라스틱 열교환기를 사용한 간접식 증발냉각장치의 성능 상관식을 여러가지 조건에서 얻어진 실험 데이터로부터 구하였으며, 이 상관식을 이용하여 환기와 외기의 조건을 변화시켜가면서 장치의 성능변화를 예측하였다. 또한 간접식 증발냉각장치의 배기열 회수에 의한 에너지 절약효과를 우리나라 몇개 도시의 표준기상데이터를 사용하여 분석하였다. 여름철 배기열 회수를 위한 현열냉각장치의 사용율은 평균 44.3%이며 증발냉각장치의 사용율은 96.7% 이다. 증발냉각장치의 배기열 회수에 의한 에너지 절약은 현열냉각장치에 비해서 훨씬 높으며, 서울의 경우 약 3.89 배로 나타났다.

열전냉각시스템을 이용한 컴퓨터의 발열제어에 관한 연구 (A Study on Control of Heat Generation in Computer using Thermoelectric Cooling System)

  • 오율권;양호동
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.43-49
    • /
    • 2015
  • 현재의 컴퓨터는 고성능화, 다기능화, 소형화, 경량화 등의 이유로 인해 기기 내부에서 발생하는 열량이 증가하고 있는 추세이다. 컴퓨터의 성능을 높이고 수명을 연장하기 위해서는 발열을 효과적으로 제어할 수 있어야 한다. 본 연구에서는 열전소자를 이용한 열전냉각시스템을 구성하여 컴퓨터에 설치하였고, 실험을 통해 기존의 공기냉각시스템을 사용한 컴퓨터 내부의 온도분포와 열전냉각시스템을 함께 사용한 컴퓨터 내부의 온도분포를 측정한 후, 이를 비교하여 열전냉각시스템의 발열제어 성능을 알아보고자 하였다. 또한, 열전냉각시스템이 기존의 컴퓨터 냉각시스템을 대처할 수 있는 성능을 낼 수 있는지 예측해 보기 위해서 기존의 냉각시스템을 사용한 컴퓨터와 열전냉각시스템만을 사용한 컴퓨터 내부의 온도분포를 수치해석을 통해 예측하고 비교해 보았다.

자동차에서의 냉각팬의 날개 형상에 대한 유동해석 (A Flow Analysis on Wing Shape of Cooling Fan at Automobile)

  • 조재웅
    • 한국융합학회논문지
    • /
    • 제5권4호
    • /
    • pp.75-79
    • /
    • 2014
  • 본 연구에서는 자동차 냉각팬에 대해서 유동해석을 수행하였다. 냉각팬의 형상에 대하여 유동 조건은 같게 하여 Canival, Teracan 및 basic 3가지의 모델을 CATIA프로그램으로 설계하여 본 해석을 실시하였다. 날개의 모양에 따라 유체의 속도의 등고선이 변화하는 것을 볼 수 있으며, 날개의 모양 또는 넓이에 따라 각기 다른 압력분포를 볼 수 있었다. 세 가지 모델 중, Teracan 모델인 냉각팬이 공기의 유동이 많아 라디에이터의 열을 식히는데 가장 효율적이 된다고 사료된다. 그리고 디자인 면에서의 융합 기술로의 접목도 가능하여 미적인 감각을 나타낼 수 있다.

물-공기 직접접촉식 공기조화장치의 성능해석 (Performance Analysis of Water/Air Direct Contact Air Conditioning System)

  • 유성연;권화길;김광영
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

엔진 오일의 공기 혼입과 윤활 특성

  • 최재권
    • Tribology and Lubricants
    • /
    • 제11권4호
    • /
    • pp.1-12
    • /
    • 1995
  • 여러 가지 필수적인 윤활유 성상과 함께 요즘 개발된 엔진에서 요구되는 중요한 특성 중 하나가 윤활유 내의 공기 혼입(aeration) 문제이다. 만일 윤활유 내에 공기가 일정 한도 이상 혼입되면 윤활유가 수행하는 일반 기능 중 하중을 분산시키는 압력 분산 작용과 윤활 작용 및 마찰열을 식혀 주는 냉각 작용이 제대로 되지 않아 엔진 수명과 내구성에 심각한 문제를 초래한다. 특히 현재 밸브 소음 저감 및 정비성 향상을 위해 대부분의 엔진에서 채용하고 있는 hydraulic valve lash adjuster(HLA)에 미치는 영향이 가장 심각하다. HLA는 그 작동 특성이 엔진 오일의 비 압축성을 이용하고 있기 때문에 만일 HLA 내부의 고압실에 공기가 오일에 섞여 들어간다변 밸브 시스템 강성이 떨어지게 되어 오히려 HLA 사용 목적에 반해 밸크 이상 거동에 의한 소음이 유발될 뿐만 아니라 심하면 밸브가 파단되는 심각한 현상이 초래되기도 한다. 상기한 바와 같이 aeration 현상은 경우에 따라 매우 심각한 문제를 유발하기도 하며 엔진이 고속 고출력화 하면서 그 특성은 더욱 관심사가 되어 왔다. 따라서 엔진 각 부분의 올바른 기능과 신뢰성 확보를 위해 aeration의 특징 발생 원인 및 대책을 살펴보고 특히 oil aeration이 HLA와 엔진 베어링에 미치는 영향에 대해 분석 고찰해 봄으로써 그 특성을 이해하고자 한다.

용존산소 제거용 중공사 탈기막의 방사선장하에서의 영향평가에 대한 연구

  • 김문수;이두호;강덕원
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.229-229
    • /
    • 2004
  • 원자력발전소에서 원자로 냉각재 중의 용존산소 제어는 원자로 냉각재 계통에서의 전면 부식과 다양한 형태의 응력부식균열(SCC)를 완화시키는데 기여한다. 원자로 냉각재 계통내에 용존 되어있는 산소는 발전소 기동 시에는 하이드라진($N_2H_4$)을 넣거나 인위적 배기를 통해 제거하고, 정상운전 중에는 체적제어탱크(VCT)에 수소를 가압하여 제거시킨다. 계통내로 유입되는 용존산소를 최대한 억제하기 위하여 대부분의 원자력발전소는 원자로 보충수 탱크 상층부에 질소를 주입하여 탱크로 유입되는 공기를 차단하고 있으나, 이 과정에서 일부 수중에 용해되어 들어가는 질소는 계통 내에서 NH$_3$를 형성하여 화학체적제어계통(CVCS)의 이온교환 수지탑에 치환됨으로서 기포화 되어있는 Li을 계통으로 빠져나오게 하여 계통 pH에 영향을 미친다.(중략)

  • PDF

A/C 콘덴서를 포함한 차량냉각 성능예측에 관한 연구 (A Study on Prediction Method of Vehicle Cooling Performance with A/C Condenser)

  • 이상호;박정원
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.51-60
    • /
    • 2002
  • An analysis method to predict performance of a vehicle cooling system which is composed of radiator, A/C condenser, cooling fan, and etc. is suggested. Air flow through the heat exchanger system and heat rejection rate which dominate the cooling performance are analyzed. Heat transfer with A/C refrigerant phase change is also considered in the analysis. Some predicted results are compared with experimental data for various operating conditions. This evaluation procedure will be useful for the design of optimal vehicle cooling system.

3MW 풍력발전기 구조설계 및 회전자의 동특성 해석 (Mechanical Design and Dynamic Analysis of 3MW Rotor for Wind Energy Conversion System)

  • 이홍기;김동언;정영규;한홍식;서형석;정진화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.333-336
    • /
    • 2008
  • 3MW 풍력발전기용 발전기의 구조적 특성을 소개하고 회전자의 동특성 해석을 수행하였다. 이 발전기는 증속기를 사용하였으며 정격속도는 1459 rpm 이며 30% over speed trip 조건을 적용하여 설계되었다. 회전자 pole에 전원 공급 없이 자기장을 만드는 영구자석을 사용하는 형태로 구조는 간단하다. 발전기의 냉각방법은 공극을 냉각하기 위하여 팬을 이용하여 공기를 순환하며 고정자 외형에는 냉각채널을 부착하여 냉각수를 순환한다. 회전기계의 설계 시에는 반드시 진동을 고려하여 가능하면 진동을 줄이는 방향으로 설계가 되어야 하며 회전축 계의 설계에 있어서는 계의 강도, 위험속도, 불평형 진동응답 및 안정성 등을 고려하여야 한다. 본 논문에서는 물리설계를 기본으로 하여 설계된 발전기의 형상을 간단하게 설명하고, 발전기의 회전자를 상용 유한요소 해석 프로그램인 ANSYS 를 이용하여 해석을 수행하였다. 해석절차는 정적해석을 수행하고 다음으로 모드해석을 수행 하였다. 모드형상에 따른 주파수를 표기하고 해석 결과를 나타내었다.

  • PDF