• Title/Summary/Keyword: 공기공동

Search Result 259, Processing Time 0.025 seconds

Lung Cancer Incidentally Found on Surgery of Spontaneous Pneumothorax -A case report- (자연기흉 수술 중 발견된 폐암의 수술치험 1예 -1예 보고-)

  • Kim, Mi-Jung;Song, Chang-Min;Jung, Sung-Chol;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.949-952
    • /
    • 2006
  • Spontaneous pneumothorax is rarely occurred as an initial sign of primary lung cancer. As a lot of these cases have already advanced, even then surgical resection is performed, the prognosis is often undesirable, We happened to find a ruptured cavity on a 65-year-old male patient who had suffered from pulmonary tuberculosis in the past, while performing VATS bullectomy for simple spontaneous pneumothorax, Then, as a result of frozen biopsy, it was diagnosed as squamous cell cancer Because the tumor was infiltrated from the upper lobe into the lower lobe passing by fissure, we should remove by pneumonectomy and the pathologic stage was found stage I(T2N0M0). When we made an follow-up observation for one year and a half, there was neither relapse nor complication. When there appears spontaneous pneumothorax to the high risk group for lung cancer who were smokers over forty-year old, with chronic bronchitis or pulmonary emphysema, it needs to have a closer observation on a base lung disease such as lung cancer through chest CT, and it is also necessary to make more active approach by performing the surgical operation through a thoracoscopy when there is a continued air release.

A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

  • 민병균;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.109-117
    • /
    • 1997
  • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

  • PDF

Pneumothorax due to Metastasis of Angiosarcoma to the Lung (혈관 육종의 폐 전이에 의한 기흉)

  • Haam, Seok-Jin;Paik, Hyo-Chae;Kim, Chang-Wan;Kwon, Ji-Eun;Choi, Hyung-Yoon;Lee, Doo-Yun
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.228-231
    • /
    • 2010
  • An 80 year-old male with a medical history of angiosarcoma of the scalp visited the Emergency Department complaining of dyspnea, and the chest X-ray revealed pneumothorax. He has undergone scalp resection and radiotherapy three years ago due to angiosarcoma. Due to a persistent air leak, he underwent wedge resection of the lung and was pathologically diagnosed with metastatic angiosarcoma to the lung. He underwent radiotherapy following the lung resection, but he died from his disease at 15 month following surgery due to further aggravation of the lung metastasis. Angiosarcoma is a highly malignant tumor and it frequently occurs on the scalp and face in elderly patients. Angiosarcoma frequently metastasizes to the lung and it may cause pneumothorax as a consequence of a ruptured cavitary lesion. We report here on a case of pneumothorax that was caused by lung metastasis in an elderly patient with a history of angiosarcoma of the scalp.

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers (kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정)

  • Lee Kang Kyoo;Lim Chunil;Chang Sei Kyung;Moon Sun Rock;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2005
  • The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60-300 kV beam (lSO-4037) installed in KFDA and specified in energy spectra and beam qualities, and the chambers of PTW N23333 and N30001 were investigated. In calculations, the $R_{\mu}\;and\;R_{Q,Q_{0}}$ in IAEA dosimetry protocols were determined from the air kerma and the cavity dose obtained by theoretical and Monte Carlo calculations. It is shown that the N30001 chamber has a flat response of $\pm1.7\%$ in $110\~300kV$ region, while the response range of two chambers were shown to $\pm3\~4\%$ in $80\~250kV$ region. From this work we have discussed dosimetry protocol for the kV X-rays and we have found that the estimation of energy dependency is more important to apply dosimetry protocol for kV X-rays.

  • PDF

Effect of noise and reverberation on subjective measure of speech transmission performance for elderly person with hearing loss in residential space (주거 공간에서 고령자 청력손실을 고려한 소음 및 잔향에 따른 음성 전송 성능의 주관적 평가)

  • Oh, Yang Ki;Ryu, Jong-Kwan;Song, Han-Sol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.369-377
    • /
    • 2018
  • This study investigated the effect of noise and reverberation on subjective measure of speech transmission performance for elderly person with hearing loss in residential space through listening test. Floor impact, road traffic, airborne, and drainage noise were employed as the residential noise, and several impulse responses were obtained through room acoustical computer simulation for an apartment building. Sound sources for the listening test consisted of residential noises and speech sounds for boh the young (the original sound) and the aged (the sound filtered out by filters with frequency responses of hearing loss of 65 years elderly person). In the listening test, subjects evaluated speech intelligibility and listening difficulty for the presented word ($L_{Aeq}$ 55 dB) at three noise levels ($L_{Aeq}$ 30, 40, 50 dB) and three reverberation times (0.5, 1.0, 1.5 s). Results showed that the residential space with noise level lower than equal to 50 dB ($L_{i,Fmax,AW}$) for jumping noise and 40 dB ($L_{Aeq}$) for road traffic, airborne, and drainage noise had speech intelligibility of 90 % and over and listening difficulty of 30 % and below. Speech intelligibility and listening difficulty for the aged sound source was shown to be 0 % ~ 5 % lower and 2 % ~ 20 % higher than those for the young sound source, respectively.

A 3D ground penetrating radar imaging of the heavy rainfall-induced deformation around a river levee: a case study of Ara River, Saitama, Japan (폭우에 의해 발생된 강 제방 주변 변형의 3차원 GPR 영상화: 일본 사이타마현의 아라강에 대한 현장적용사례)

  • Yokota, Toshiyuki;Inazaki, Tomio;Shinagawa, Shunsuke;Ueda, Takumi
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • This paper describes a three-dimensional ground penetrating radar (GPR) survey carried out around a levee of the Ara River in Saitama, Japan, where deformation of the ground was observed after heavy rainfall associated with the typhoon of September 2007. The high-density 3D GPR survey was conducted as a series of closely adjacent four directional sets of 2D surveys at an area surrounding vertical cracks on the paved road caused by deformations induced by heavy rain. The survey directions of the 2D surveys were 0, 90, 45, and -45 degrees with respect to the paved road and the intervals between lines were less than 0.5 m. The 3D subsurface structure was accurately imaged by the result of data processing using Kirchhoff-type 3D migration. As a result, locations and vertical continuities of the heavy rainfall induced cracks in the paved road were clearly imaged. This will be a great help in considering the generation mechanisms of the cracks. Moreover, the current risk of a secondary disaster was found to be low, as no air-filled cavities were detected by the 3D GPR survey.

Thermal Energy Balance Analysis of a Packed Bed for Rock Cavern Thermal Energy Storage (충전층을 이용한 암반공동 열에너지저장시스템의 열에너지 수지 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.241-259
    • /
    • 2013
  • A packed bed thermal energy storage (TES) consisting of solid storage medium of rock or concrete through which the heat transfer fluid is circulated is considered as an attractive alternative for high temperature sensible heat storage, because of the economical viability and chemical stability of storage medium and the simplicity of operation. This study introduces the technologies of packed bed thermal energy storage, and presents a numerical model to analyze the thermal energy balance and the performance efficiency of the storage system. In this model, one dimensional transient heat transfer problem in the storage tank is solved using finite difference method, and temperature distribution in a storage tank and thermal energy loss from the tank wall can be calculated during the repeated thermal charging and discharging modes. In this study, a high temperature thermal energy storage connected with AA-CAES (advanced adiabatic compressed air energy storage) was modeled and analyzed for the temperature and the energy balance in the storage tank. Rock cavern type TES and above-ground type TES were both simulated and their results were compared in terms of the discharging efficiency and heat loss ratio.

A study on the optimal reinforcement area for excavation of a small cross-section shield TBM tunnel in fault fracture zone through parameter analysis (매개변수 분석을 통한 단층파쇄대의 소단면 쉴드 TBM 터널 굴착 시 최적 보강영역 연구)

  • Kang, Byung-Yun;Park, Hyung Keun;Cha, Jae-Hoon;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.261-275
    • /
    • 2020
  • When excavating a small cross-section tunnel in a fault fracture zone using the shield TBM method, there is a high possibility of excessive convergence and collapse. Appropriate ground reinforcement is required to minimize construction cost loss and trouble due to a fault fracture zone. In this study, the optimal reinforcement area was suggested and the surrounding ground behavior was investigated through numerical analysis using MIDAS GTS NX (Ver. 280). For the parameters, the width of the fault fracture zone, the existence of fault gouge, and the groundwater level and depth of cover were applied. As a result, when there is not fault gouge, the convergence and ground settlement are satisfied the standard when applying ground reinforcement by up to 0.5D. And, due to the high permeability coefficient, it is judged that it is necessary to apply 0.5D reinforcement. There is a fault gouge, it was possible to secure stability when applying ground reinforcement between the entire fault fracture zone from the top of the tunnel to 0.5D. And, because the groundwater discharge occurred within the standard value due to the fault gouge, reinforcement was unnecessary.

Full Scale Testing of the Effect of Stairwell Pressurization on Pressure Differential and Flow Velocity

  • Son, Bong-Sae;Park, Kyung-Hwan;Chang, Young-Bae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • A series of full-scale testing was conducted to examine the effect of stairwell pressurization on the pressure differential between the stairwell and the auxiliary room and between the auxiliary room and the residence. Also, flow velocity profiles at open doors were measured. The building tested was a condominium that had twenty floors above the ground and two floors underground. For pressurization of the stairs, a blower was used to supply air into the stairwell at one location underground. Thirteen different cases were tested, and test variables included the number of floors with open doors and the flow rate of the air supply. When the doors on the first floor were open, the pressure differential between the stairwell and the auxiliary room was distributed almost uniformly except for locations near the first floor. When the flow rate was in the range of 180~270 CMM and the doors of one floor were open, the flow velocity could satisfy the requirement of fire safety standards and the stairwell pressure was positive at all levels. However, the minimum pressure requirement (10 Pa) could not always be satisfied. When doors on two floors were open, the flow velocity requirement could be satisfied by increasing the flow rate, but it was found impractical to satisfy the minimum pressure requirement without causing excessive pressure differential in the area near the blower.

A study on the improvement of the protective shield construction method and explosion-proof tube performance for tunnel blasting (터널 발파에 대한 방호쉴드 공법 및 방폭튜브 성능 개선 연구)

  • Sang-Hwan Kim;Soo-Jin Lee;Jung-Nam Kwon;Dong-gyun Yoo;Yong-Woo Kim;Kwang-Eun Cho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.4
    • /
    • pp.285-303
    • /
    • 2023
  • Interest in building underground spaces is increasing for the creation of downtown infrastructure and efficient space utilization. A representative method of utilizing underground space is a tunnel, and in addition to road tunnels, the construction of utility tunnels such as power conduits and utility conduits is gradually increasing. The current basic tunnel construction method can be divided into NATM (New Austrian Tunnelling Method) and TBM (Tunnel Boring Machine). The NATM is a reliable method, but it is accompanied by vibration and noise due to blasting. In the case of the TBM excavation method, there are disadvantages in terms of construction period and construction cost, but it is possible to improve economic feasibility by introducing appropriate complementary methods. In this study, a blasting method was develop using the NATM after TBM pre-excavation using the protective shield method. This is a method that compensates for the disadvantages of each tunnel construction method, and is expected to reduce construction costs, blasting vibration, and noise. In order to review the performance of the developed method, an experiment was conducted to evaluate the performance of explosion-proof tube to which a protective shield scale model was applied, and the impact of blasting vibration of the protective shield method was analyzed.