• Title/Summary/Keyword: 공기공급장치

Search Result 180, Processing Time 0.025 seconds

A Method of Estimation of Energy Consumption according to a Supply Pressure for Pneumatic Cylinder Driving Apparatus (공급압력 변화에 의한 공기압 실린더 구동장치의 소비에너지 변화량 추정 방법)

  • Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.15-20
    • /
    • 2012
  • Pneumatic cylinder meter-out driving apparatus is used widely because it is clean, lightweight, and can be easily serviced. In this study an estimation method of energy consumption for pneumatic cylinder meter-out driving apparatus is proposed. The proposed method is derived from state equation and energy equation of air, and, the equation of motion of a moving part of a pneumatic cylinder reflecting the characteristics of the meter-out driving. The effectiveness of the proposed method is proved by simulation study and it demonstrates that the proposed method can evaluate the energy consumption quickly and easily when the parameters of the driving apparatus are changed.

Mechanism improvement of the heat exchanger and the ventilator for the thermal efficiency increment of hot-air heater (온풍난방기의 열이용효율 증대를 위한 열교환부 및 송풍기 구조개선)

  • 이기명;박규식;최성우
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.558-563
    • /
    • 2002
  • 시설원예에서 난방장치를 사용하는 겨울철 재배 농산물의 생산비 중 난방 연료비가 30%~37% 정도를 차지하여 비중이 가장 높다. 따라서 시설원예 농가에서는 난방비를 절감하는 것이 농가소득과 직결되므로, 난방장치의 선정이 대단히 중요하다. 본 연구에서는 겨울철 재배 농산물의 생산비 중 30%-37% 정도를 차지하는 연료비를 절감하기 위해 기존의 온풍난방기와 다른 새로운 방식의 열교환기와 원심식 송풍블로워를 사용하는 블로워 송풍방식의 온풍난방기를 개발하고 개발된 온풍난방기의 가동으로 인한 난방 연료비 절감효과와 온실내의 균일한 온도분포를 획득하기 위해 8연동 비닐온실에서의 시험을 실시하였으며 얻어진 결과를 요약하면 다음과 같다. 가. 저 정압용의 전동기 축직결식 송풍팬을 대신하여 고 정압용의 블로워 송풍팬을 장착하고 열교환 면적을 크게 한 지그재그식 환류의 열교환실을 채용한 온풍난방기를 개발하였다. 나. 공시한 온실에서 기존 온풍난방기의 2일 가동시 DH당 연료 사용량이 평균 1.082$\ell$/$^{\circ}C$.hr 이며, 블로워 송풍방식 온풍난방기의 3일 가동시 DH당 연료 사용량은 평균 0.854$\ell$/$^{\circ}C$.hr로써 21%의 난방 연료비 절감효과가 나타났다. 다. 블로워 송풍방식 온풍난방기는 동일시간대 3$^{\circ}C$의 경시적 온도변화가 발생하였고, 기존의 은풍난방기의 동일시간대 온도변화는 최대 6.1$^{\circ}C$로 나타나 개발된 블로워 송풍방식 온풍난방기가 동일시간대 온실내의 온도변화를 크게 줄일 수 있었고 온도분포를 비교적 균일하게 하는 효과가 있음을 확인하였다.도 33$^{\circ}C$를 기준으로 한 열 회수 시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$ 일 각각 120분 및 140분으로 나타났다. (3) 제 3종 자갈: 축열조로 공급되는 공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때, 축열조 출구의 공기온도가 33$^{\circ}C$에 도달될 때까지 가열되는데 소요된 시간은 가열공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때 각각 180분과 150분이었고, 방열에 소요된 시간은 각각 240분 및 270분으로 나타났다. 방열과정 동안 축열조 출구의 최고 공기온도는 가열 공급공기의 온도가 52$^{\circ}C$$65^{\circ}C$일 때 각각 35.5$^{\circ}C$ 및 39.5$^{\circ}C$였다. 출구 공기온도 33$^{\circ}C$이상을 기준으로 한 에너지 회수시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$일 때 각각 140분 및 160분으로 나타났다. 이와 같이 자갈이 작을수록 축열조 출구의 공기온도가 기준온도 33$^{\circ}C$에 도달되는 시간이 길었으며, 이것은 축열조내의 공극이 작고 비중량이 커 자갈층을 가열시키는 축열시간이 길어지기 때문인 것으로 사료된다. 또한 작은 자갈일수록 방열시간도 다소 길어져 회수 가능 열에너지가 큰 것으로 나타났다

  • PDF

Cognitive Performance Following Oxygen Administration (외부 산소 공급에 따른 인지 능력 변화)

  • 정순철;이유진;이정미;손진훈;김승철
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.05a
    • /
    • pp.111-114
    • /
    • 2003
  • 산소는 인간의 신체 및 정신 활동에 필수적인 물질이며, 특히 뇌 기능에 중요한 역할을 수행한다. 본 연구에서는 일반 공기 중의 산소 농도(21%) 환경에 비해 외부에서 고 농도(30%)의 산소 공급이 인지 능력 중 특히 공간 지각 능력에 어떠한 변화를 유발하는지 관찰하고자 한다. 8명의 남자 대학생(평균 23.5세)을 본 연구의 실험 참여자로 선정하였다. 21%와 30% 산소 농도를 각각 8L/min의 양으로 일정하게 공급할 수 있는 장치를 개발하여, 마스크를 통하여 실험 참여자에게 전달하였다. 공간 지각 능력 측정으로 위해 각각 20문항을 포함하는 두 개의 문제지를 제작하였고, 과제 수행 결과로부터 정답률과 평균 반응 시간을 산출하였다. 평균 정답률은 21%와 30% 산소 농도에서 각각 50.63 $\pm$ 8.63과 62.50 $\pm$ 9.64 이었고, 두 농도간의 통계적 유의차가 발생하였다. 평균 반응 시간의 21%와 30% 산소 농도에서 각각 6.60 $\pm$ 0.77〔sec〕이었고, 두 농도간의 통계적 유의차가 발생하지 않았다. 본 연구 결과로부터 외부에서의 고농도의 산소 공급이 공간 지각 능력 증가에 긍정적인 영향을 미친다는 결론을 도출할 수 있다.

  • PDF

Changes of $SPO_2$, heart rate and GSR at resting state due to oxygen administration (안정상태에서 외부의 산소공급에 따른 혈중산소포화도, 심박동율, 피부전도도의 변화)

  • 정순철;이현정;민병찬;김승철
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.11a
    • /
    • pp.71-73
    • /
    • 2003
  • 본 연구에서는 안정 상태에서 일반 공기 중에 산소 농도(21%) 환경에 비해 외부에서 고 농도(35%)의 산소 공급이 혈중 산소 포화도(SPO2), 심박동율(Heart rate), 피부전도도(Galvanic skin response)에 어떠한 영향을 미치는지를 검증하고자 한다. 35%의 고농도 산소를 2L/min의 양으로 일정하게 공급할 수 있는 산소 공급 장치를 이용하였고, 뇌 질병이 없는 5명의 대학생들이 피험자로 참여하였다. 21%의 비해 35% 산소 농도에서 모든 실험 참여자의 3분 동안의 평균 심박동율은 감소하였고 평균 혈중 산소 포화도는 증가하였다. 그러나 피부전도도는 차이가 없었다.

  • PDF

An fMRI study on verbal cognition ability due to oxygen administration (외부의 산소 공급에 따른 언어 능력 변화에 대한 뇌기능 연구)

  • 김익현;정순철;김승철;손진훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.11a
    • /
    • pp.1111-1115
    • /
    • 2003
  • 본 연구에서는 일반 공기 중의 산소 농도(21%) 환경에 비해 외부에서 고 농도(30%)의 산소 공급이 인지 능력 중 특히 언어 능력에 어떠한 변화를 유발하는지 관찰하고자 한다. 9명의 오른 손잡이 남자 대학생을 본 연구의 실험 참여자로 선정하였다. 21%와 30% 산소 농도를 각각 8L/min의 양으로 일정하게 공급할 수 있는 장치를 개발하여, 마스크를 통하여 실험 참여자에게 전달하면서 언어 과제를 수행하게 하였다. 동시에 3T MRI를 이용하여 뇌기능 영상을 획득하였다. 언어 능력 측정을 위해 28 문항을 포함하는 두 개의 문제지를 제작하였고, 과제 수행 결과로부터 정답률을 산출하였다. 21%에 비해 30% 산소 농도에서 평균 정답률은 유의미한 증가를 하였고, 뇌 활성화 양도 증가하였다. 본 연구의 결과로부터 외부에서의 고농도의 산소 공급이 언어 능력 증가에 긍정적인 영향을 미친다는 결론을 도출할 수 있다.

  • PDF

The Effect of the Air Temperature and Air-assisted Pressure on the Fuel Droplet Atomization (분무 공간의 공기온도와 보조공기의 공급압력이 연료입자의 미립화에 미치는 영향)

  • Kim, Y.S.;Lee, J.S.;Yoon, S.H.;Chung, S.S.;Ha, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.16-24
    • /
    • 1998
  • The fuel injection type, in the gasoline engines of atomization of fuel droplet and its distribution hae influenced directly on the decision of engine performance and harmful emission. In this paper, atomization characteristics of fuel spray is investigated with microscopic visualization system. Particle motion analysis system is used to measure the SMD from fuel spray of air-assisted injector by initial factors such as temperature of ambient air and air-assisted pressure. As air-assist pressure and ambientair temperature increase, the SMD is decreased, and its variation is more stable.

  • PDF

Design and Performance Test of Cooling-Air Test Equipment for the Environmental Control System in Aircraft (항공기 ECS 냉각공기 시험장비 설계 및 성능 시험)

  • So, Jae-uk;Kim, Jin-sung;Kim, Jae-woo;Kim, Jin-bok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • In this paper, the configuration and design of the test equipment are presented to examine the impact of rapid temperature change in cooling-air that may occur during the operation of the fixed wing aircraft Environmental Control System (ECS) on avionic electronic equipment. At the start of the ECS, the temperature of the air supplied by the aircraft ECS may be increased to 5.0℃ per second. In order to ensure operating of the avionic electronic equipment that is mounted on the aircraft and receives cooling-air from the ECS, testing equipment that can implement the cooling-air characteristic test environment is required. During design of test equipment was verified cooling-air rapid rate of temperature change by performing a thermal/flow analysis, performance of the test equipment implemented was verified by applying an avionic electronic equipment.

Development of A Drying Unit of Agricultural Wastes (농업폐기물 건조장치 개발)

  • Song, Dae Bin;Lim, Ki Hyeon;Jung, Dae Hong
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.115-115
    • /
    • 2017
  • 2013년 국내 시설(비닐, 유리 온실)에서 재배되는 토마토, 풋고추, 파프리카의 생산량은 총 632,315 톤으로 잎, 줄기 등 발생되는 부산물은 수확량의 약 30%에 해당되는 189,695 톤으로 추정되며 대부분 노지에 방치 유실되거나, 소각 처리된다. 본 연구에서는 이처럼 단순 폐기되는 농업폐기물을 재활용한 고형연료 제조에 필요한 건조장치를 개발하고 실험을 통해 그 성능을 확인하고자 하였다. 연구를 위해 건조용량 100 kg/hr인 실험실용 건조기를 제작하였다. 경상남도 진주시 농업기술원 온실에서 재배되는 파프리카, 토마토, 딸기, 가지, 고추 등의 부산물을 실험원료로 사용하였다. 원료성상, 원료이송방식, 송풍량, 건조온도, 건조시간에 따른 부산물 건조특성을 파악하였다. 원료를 비교적 짧게 절단하고 열풍이 배출되는 다공판위를 견인형 컨베어로 이송시키는 형태의 경우 건조실험 결과 세절된 원료에서 추출된 내부 수분이 외부로 유출되어 원료들 사이의 공극을 채워 건조공기가 원료층을 통과하지 못하게 하고, 특히 $100^{\circ}C$ 이상 고온에 노출되는 경우 원료표면에 잔류하는 유출 수분이 건조되면서 막을 형성하여 내부 원료들은 전혀 건조가 되지 못하는 현상이 관측되었다. 이러한 원료내부의 공극형성 불량으로 국부적으로 공기가 통과되는 부분만 집중적으로 급격한 건조가 진행되고 공급된 건조공기 대부분이 이 부분으로 유출되어 효과적인 건조가 전혀 진행되지 못하였다. 피건조물 사이의 공극형성을 위해 원료를 절단하지 않고 수행한 건조실험 결과 건조 풍량 및 온도에 따라 건조속도 및 처리용량이 다르게 나타나는 것을 알 수 있다. 특히 송풍량과 압력을 증가 시킨 건조 결과로 건조 상하층 간 불균일 건조 해소 및 건조속도, 건조능력에서 연구목표 치를 상회하는 결과를 보여준다. 특히 건조공기온도 $150^{\circ}C$ 이하에서 풍량을 증가시켜서 원하는 건조작업 수행이 가능함을 확인할 수 있었다.

  • PDF

Development and Performance Evaluation of a Liquid Particle Generator (액적 발생 장치 개발 및 성능 평가)

  • Heo, Jung-Hyuk;Kim, Dae-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4334-4340
    • /
    • 2012
  • In this work, we developed and evaluated the Liquid Particle Generator for generating fine particles in the air. The Liquid Particle Generator, which was based on the spray-evaporation method, had two kinds of orifices: 0.3 mm and 0.5 mm. The Liquid Particle Generator was operated at different pressure between 1 bar and 4 bars to find relationship between input pressure and droplet output rate. In addition, the size distribution of the droplets generated by the Liquid Particle Generator with different orifices was measured by the SMPS system and the optical particle counter. As a result, it was shown that the Liquid Particle Generator with 0.3 mm orifice generated droplets of around 0.3 ${\mu}m$ and atomized particles very stably. The Liquid Particle Generator having 0.5 mm orifice generated bigger droplets, compared with the Liquid Particle Generator with 0.3 mm orifice. Additionally, in these Liquid Particle Generators (0.3 mm and 0.5 mm orifice), little coagulation of particles did occur because of fine droplets atomized by the jet. Therefore, the Liquid Particle Generator could be used as an aerosol generator for atomizing fine particles.

Humidification model and heat/water balancing method of PEMFC system for automotive applications (자동차용 연료전지 시스템의 가습모델과 열/물균형 유지방법)

  • Jung, Seung-Hun;Yoon, Seok-Ho;Kim, Min-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.339-344
    • /
    • 2005
  • A PEMFC system model for FCEV was constructed and simulated numerically to examine the heat/water flow of the system and air/fuel humidification process for various operation conditions (ambient pressure /temperature/humidity, operating temperature, power load). We modeled PEMFC stack which can generate maximum electricity of about 80 kW. This stack consists of 400 unit cells and each unit cell has $250cm^2$ reacting area. Uniform current density and uniform operating voltage per each cell was assumed. The results show the flow characteristics of heat and water at each component of PEMFC system in macro-scale. The capacity shortage of the radiator occurred when the ambient was hot $(over\;40^{\circ}C)$ and power level was high (over 50 kW). In spite of some heat release by evaporation of water in stack, heat unbalance reached to 20kW approximately in such a severe operating condition. This heat unbalance could be recovered by auxiliary radiators or high speed cooling fan with additional cost. In cold environment, the capacity of radiator exceeded the net heat generation to be released, which may cause a problem to drop the operating temperature of stack. We dealt with this problem by regulating mass flow rate of coolant and radiator fan speed. Finally, water balance was not easily broken when we retrieved condensed and/or unused water.

  • PDF