• Title/Summary/Keyword: 공기가열기

Search Result 98, Processing Time 0.022 seconds

A Study on Cooling Condition for Quality Improvement of Rotary Molding Machine (회전성형기의 품질 향상을 위한 냉각 조건에 관한 연구)

  • Kang, Jeong-Seok;Kim, In;Lee, Myungjae;Yoon, Jai-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.367-371
    • /
    • 2019
  • The molding for hollow products used widely in industry is rotational molding by heating and cooling. Uniform cooling is required to improve the quality of the product, and rapid cooling is required to improve the productivity. In this paper, the cooling condition is largely classified into the case of no forced cooling by the fan and forced cooling by the fan. In addition, when forced cooling by the fan is not performed, the condition for stopping the molding machine horizontally and the condition for stopping the molding machine vertically were classified. To confirm the forced cooling by the fan, the conditions were set such that only the molding machine rotates while the fan is not running and the upper and lower fans operate when only the lower fan is operated. The surface temperature of the rotary molding machine was analyzed by the STAR-CCM+ program for the case of air-cooling. The temperature distribution of the rotary molding machine was analyzed for five conditions and the temperature distribution for cooling was compared under each condition. Among the five cases, Case 4 was lowest at approximately 35 ℃ after 900sec.

Red Pepper (Capsicum annum) Drying Using Flat-Plate Solar Collectors (평판집열기(平板集熱機)를 이용(利用)한 고추 건조(乾燥)에 관(關)한 연구(硏究))

  • Kim, Dong-Man;Kim, Man-Soo;Chang, Kyu-Seob
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.1
    • /
    • pp.56-64
    • /
    • 1979
  • Two types of fiat-plate collector were designed and constructed for utilizing the solar energy as heating source of red pepper drying. It was performed to investigate the basic factors on using the collectors and the drying effect on various types of red pepper, and the results obtained are summarized as follows. 1. The optimum tilted angles of the collector in Daejeon area were ${\phi}-15^{\circ}$ in summer season and ${\phi}+15^{\circ}$ in winter season when it was adjusted two times per a year: 2. In the conditions during experiment period, average atmospheric temperature and relative humidity were $25.6^{\circ}C$ and 52.6%, respectively, and $42.0^{\circ}C$, 74.2% in the control chamber. The temperature in the drying chamber connected to the water heater was the highest but relative humidity in the chamber connected to the air heater was the lowest among the chambers. 3. The drying velocity of whole red pepper in the chamber connected to the water heater was the fastest as 2.3 times as compared to the whole type on the mat drying followed by air heater and control in decreasing order. The horizontally cut red pepper in the chamber connected to the water heater was dried exceedingly fast among twelve plots. 4. The content of capsaicine as pungent principle and of capsanthine as red pigment in the red pepper were reduced during drying but there were no differences significantly on the drying method, and it could not affect much on the quality of dried product.

  • PDF

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

Component Analysis of Softwood Vinegar (침엽수 목초액의 성분분석)

  • ;;;Sano Yoshihiro
    • Journal of Korea Foresty Energy
    • /
    • v.20 no.1
    • /
    • pp.28-34
    • /
    • 2001
  • To analyze chemical compositions of softwood vinegar prepared with continuous carbonized kiln, the chemical compositions were analyzed by GC-MS spectrometry. The results were summarized as follow : 1. The amounts of methylalcohol and acetic acid and of vinegar were 0.12% and 0.8% respectively, and acidity was 0.85 2. Perfume components of vinegar were frufual, 5-meayl-2-furancarboxyaldehyde, 2,3-pentanedione, 2-butanol, 2,3-dihydrofuran, 1-(2-furanyl)-etanone, benzaldehyde, 2-furan carboxyaldehyde and acetic acid. 3 Vinegar prepared from softwood, so that murk amount of guaiacyl compound and phenol derivetives are produced from lignin and extractives was analγzed. 4 The yield of 4-methyl-di-tert-butylphenol was the highest in the nutural and carbonyl and acetic acid in the acid fractions, 3-ethylpentane in the basic fraction, and guaiacol in the phenolic fraction.

  • PDF

The Early Detection of the Protein Toxin using Sanification and Fluorescent Dye in the Field (현장에서 초음파 파쇄와 형광시약을 이용한 단백질 독소의 조기 탐지)

  • Ha, Yeon-Chul;Choi, Ki-Bong;Kim, Seong-Joo;Choi, Jung-Do
    • KSBB Journal
    • /
    • v.22 no.1
    • /
    • pp.48-52
    • /
    • 2007
  • This study was carried out to establish the optimum disruption condition of a sonificator for the protein toxin for the purpose of developing automatic biological agent detector equipped a sonificator. One of the best-known collisional quenchers is molecular oxygen, which quenches almost all known fluorophores. The sonification does an excellent job of degassing, which decreased the quenching effect and increased the fluorescence quantity. The fluorescence measurement for the protein using 0.7 X fluorescent dye concentration and above must be done in 1 minute and the fluorescence measurement for the protein using 0.3 X fluorescent dye concentration and below has to be done between 2 and 3 minute. The fluorescence quantity of the sonificatied protein sample was much higher that of the non-sonificatied protein sample. Sonificating the sample turned out to be favorable for the fluorescence measurement when measuring at the low protein concentration.

A Glove Box for the Subsampling of Suboxic and Cold Core Sediment (아산화 및 저온의 코아 퇴적물 중 부시료 채취를 위한 글러브박스)

  • JUNG, HOI-SOO;KWEON, SOO-JAE;KIM, CHONG-KUN
    • 한국해양학회지
    • /
    • v.25 no.4
    • /
    • pp.240-244
    • /
    • 1990
  • To solve two problems, temperature shock to the man and difficulty in exchanging the air in the glove box into N2 gas, during the subsampling of Suboxic and cold core sediments, a portable glove box with a refrigerating machine and a gas exchanging bag was constructed for subsampling of sediment cores on board. The refrigerator of the glove box can cool down 200 litter air at 30$^{\circ}C$ to 2$^{\circ}C$${\pm}$2$^{\circ}C$ within 5 minutes. The box was successfully operated during the second KORDI's deep sea research cruise of 1989 in the North equatorial Pacific. Pore water data obtained from the cruise show no evidence for artifacts caused by warming up or oxidation of sediments during subsampling.

  • PDF

Gas-sensing Characteristics of $WO_3$-$SnO_2$Thin-film Sensors ($WO_3$-$SnO_2$박막 센서의 가스감지특성)

  • 유광수;김태송
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.12
    • /
    • pp.1180-1186
    • /
    • 2001
  • W $O_3$-Sn $O_2$thin film sensors with approximately 1${\mu}{\textrm}{m}$ in thickness were fabricated by using a high-vacuum resistance-heating evaporator, were annealed at 50$0^{\circ}C$ for 4 hours in air, and then their crystallinities and surface microstructures were analyzed. As results of gas-sensing characteristics to oxidizing gas, N $O_2$, and reducing gas, CO, of 100 ppm, the highest gas sensitivities (S= $R_{gas}$/ $R_{air}$) were the W $O_3$thin-film sensor measured at 25$0^{\circ}C$ for N $O_2$(S≒1000) and the Sn $O_2$thin-film sensor measured at 15$0^{\circ}C$ to 25$0^{\circ}C$ range for CO (S≒0.25), respectively.ely.

  • PDF

A study on the burn-in test to accomplish high quality cockpit air of an ultra-sonic aircraft in the early stage of production (생산 초기 초음속 항공기 조종석의 고품질 공기 확보를 위한 burn-in test 연구)

  • Shin, Jae Hyuk;Park, Sung Jae;Seo, Dong Yeon;Jeong, Suheon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.871-876
    • /
    • 2016
  • Abnormal odor similar with burning smell often appears at the cockpit in the beginning of ultra-sonic aircraft without air filter due to the heating of production materials remained at the bleed air duct. Sources of the odor should be removed by burn-in test before test flight in order to prevent pilot confuses order with emergency such as fire of engine. However, the present method cannot prevent abnormal odor completely at the high altitude flight because maximum temperature of flight is higher than it of burn-in-test. This paper suggests burn-in test improved based on the analysis of thermal conditions of high altitude flight. It is verified that the existing burn-in test cannot cover thermal conditions of high altitude flight due to the discontinuous flow control, high change rate of temperature per unit time and difference between limit temperature of condenser and turbine. In order to overcome the limitations of current methods, the new burn-in test with continuous flow control are suggested. The continuous flow control are achieved by ram air inlet control. The effect of suggested method are verified by ground tests and flight tests. The results show the bleed air temperature can cover the temperature of high altitude flight and prevent abnormal odor at the flight test.

A Study On the Electrical Characteristic of WO3 and NiO-WO3 Thin Films Prepared by Thermal Evaporation (Thermal Evaporation법에 의해 제조된 WO3 박막과 NiO-WO3박막의 전기적 특성에 관한 연구)

  • Na Eun-young;Na Dong-myong;Park Jin-seong
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.1
    • /
    • pp.32-36
    • /
    • 2005
  • [ $WO_3$ ] and $NiO-WO_3$ thin films were deposited on a Si (100) substrate by using high vacuum thermal evaporation. The effects of various film thicknesses on the surface morphology $WO_3$ and $NiO-WO_3$ thin films were investigated. X-ray diffraction (XRD), Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy(XPS) were employed to characterize the deposited films. The results suggest that as $WO_3$ thin films became thick, their grain grew up to a $0.6{\mu}m$. On the other hand, NiO-doping to $WO_3$ thin films inhibited the grain growth five times less than undoped $WO_3$ thin films. This results show that NiO doping inhibited the grain growing of $WO_3$ thin films. Also, the variation of NOx sensitivity $(R_{NOx}/R_{air})$ to the thickness of $WO_3$ and $NiO-WO_3$ thin films were measured according to the thickness change of thin films and the working temperature of sensor in 5ppm NOx gas. As a result, $NiO-WO_3$ thin films showed more excellent properties than $WO_3$ thin films for NOx sensitivity.

Studies on the Sources of Bacterial Contamination in U. H. T. Processed Milk (살균시유(殺菌市乳)의 세균오염원(細菌汚染源)에 관한 연구(硏究))

  • Kim, Jong Woo
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.103-108
    • /
    • 1980
  • In order to elucidate the source of bacterial contamination during processing U. H. T. milk and to ensure its hygienic control, bacterial numbers were determined each step of the processes on the milks, water, tanks and pipe lines, and environments. The results obtained were as follows. 1. The viable numbers of mesophilic bacteria were $1.2{\sim}1.9{\times}10^7/ml$ of milk in the storage tank and in pipe line connected to the preheater. These were decreased to $7.0{\times}10cells{\sim}3.4{\times}10^2cells/ml$ after preheating and homogenization, and to $1.0{\times}10cells/ml$ after sterilization, then increased up to $1.2{\times}10^2cells/ml$ after packing. 2. The numbers of thermophilic bacteria were $5.0{\times}10cells{\sim}1.0{\times}10^2cells/ml$ of milk before preheating ; $3.0{\sim}5.0{\times}10cells/ml$ after homogenization ; none in the sterilizer and surge tank ; and $1.0{\sim}8.0{\times}10cells/ml$ after packing. 3. The levels of psychrophilic bacteria were $1.0{\sim}3.7{\times}10^6cells/ml$ of milk before preheating ; $1.0{\sim}4.0{\times}10cells/ml$ after homogenization ; $1.0{\times}10cells/ml$ after sterilization ; and $2.0{\times}10cells{\sim}2.5{\times}10^2cells/ml$ after packing. 4. No coliform bacteria were detected after sterilization, while the level before preheating was $2.1{\times}10^4cells{\sim}6.5{\times}10^5cells/ml$ of milk. 5. The level of mesophiles was $3.0{\times}10cells{\sim}7.4{\times}10^2cells$ in the environmental air, water supply, and unfilled packs and bottles ; that of thermophiles $1.0{\sim}3.0{\times}10cells$ in the air and water ; that of psychrophiles $1.0{\times}10cells{\sim}1.0{\times}10^2cells$ in the air, water, packs and bottles ; however no coliform was detected.

  • PDF