• Title/Summary/Keyword: 공기가열기

Search Result 98, Processing Time 0.021 seconds

Temperature Distribution in Water Cascading Horizontal Retort (열수식 살균기의 온도 분포에 관한 연구)

  • Chung, Myong-Soo;Ahn, Tae-Hoe;Lee, Yong-Gab;Yoo, Moo-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.827-833
    • /
    • 1995
  • Temperature distribution tests for a water cascading horizontal retort utilizing superheated water with overpressure as a heating medium were carried out under three different loading conditions, that is, empty(P-0), half-fully(P-3000) and fully(P-6000) loaded operating conditions. Tank volume and full loading capacity of sterilizer used for this study were about 5,900 liter and 1,140 kg(6000 pouches having 190 g weight each), respectively. Set point condition for sterilization was $122^{\circ}C$, 23 minutes and pressure was maintained in the range of $1.8{\sim}2.0\;kg/cm^2$ during sterilization. For each experiment, time-temperature data and F values were obtained from temperature microprocessor($F_0$ monitor). There were significant variations in the temperature distribution at different positions in the sterilizer. The temperature distribution was also affected by the pouch loading condition significantly. The application of the temperature distribution test to a product (retort pouched curry sauce) was conducted at the fully(P-6000) loading condition. Although heat transfer parameters($f_h\;and\;f_c$), and F values were varied with the position of sterilizer, sensory evaluation showed that the temperature distribution of the sterilizer used in this study didn't affect the quality of retorted curry sauce.

  • PDF

On Securing Continuity of Long-Term Observational Eddy Flux Data: Field Intercomparison between Open- and Enclosed-Path Gas Analyzers (장기 관측 에디 플럭스 자료의 연속성 확보에 대하여: 개회로 및 봉폐회로 기체분석기의 야외 상호 비교)

  • Kang, Minseok;Kim, Joon;Yang, Hyunyoung;Lim, Jong-Hwan;Chun, Jung-Hwa;Moon, Minkyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.3
    • /
    • pp.135-145
    • /
    • 2019
  • Analysis of a long cycle or a trend of time series data based on a long-term observation would require comparability between data observed in the past and the present. In the present study, we proposed an approach to ensure the compatibility among the instruments used for the long-term observation, which would allow to secure continuity of the data. An open-path gas analyzer (Model LI-7500, LI-COR, Inc., USA) has been used for eddy covariance flux measurement in the Gwangneung deciduous forest for more than 10 years. The open-path gas analyzer was replaced by an enclosed-path gas analyzer (Model EC155, Campbell Scientific, Inc., USA) in July 2015. Before completely replacing the gas analyzer, the carbon dioxide ($CO_2$) and latent heat fluxes were collected using both gas analyzers simultaneously during a five-month period from August to December in 2015. It was found that the $CO_2$ fluxes were not significantly different between the gas analyzers under the condition that the daily mean temperature was higher than $0^{\circ}C$. However, the $CO_2$ flux measured by the open-path gas analyzer was negatively biased (from positive sign, i.e., carbon source, to 0 or negative sign, i.e., carbon neutral or sink) due to the instrument surface heating under the condition that the daily mean temperature was lower than $0^{\circ}C$. Despite applying the frequency response correction associated with tube attenuation of water vapor, the latent heat flux measured by the enclosed-path gas analyzer was on average 9% smaller than that measured by the open-path gas analyzer, which resulted in >20% difference of the sums over the study period. These results indicated that application of the additional air density correction would be needed due to the instrument heat and analysis of the long-term observational flux data would be facilitated by understanding the underestimation tendency of latent heat flux measurements by an enclosed-path gas analyzer.

Numerical Analysis on Heat Gain of Liquid from Ambient Air with Various Fin Heights and Pitches of Fin-and-Tube Heat Exchanger in Hybrid Solar Collector (핀-튜브 열교환 구조를 갖는 복합집열기에서 핀 높이 및 간격에 따른 공기열 이용 액체 가열 성능에 관한 수치해석 연구)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Lyu, Nam-Jin;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.53-61
    • /
    • 2016
  • Solar assisted heat pump system uses solar thermal energy as a heat source of evaporator of heat pump. So, COP can be enhanced as well as collector efficiency. For improving performance of this system, some research about hybrid solar collector that has fin-and-tube heat exchanger has been conducted. This collector can get a thermal energy from ambient air for liquid heating, so heated liquid can be used as a heat source of evaporator in heat pump even the solar radiation is not enough. In this study, numerical analysis was conducted for confirming heat gain of liquid according to fin height and pitch of fin-and-tube heat exchanger in collector. As a result, higher heat gain was obtained on lower fin height and narrow fin pitch, but the pressure drop also increased with increment of heat gain. Thus the JF factor considering both heat transfer enhancement and pressure drop was investigated and the maximum value was shown when the fin height and pitch were 40mm and 45mm. So it is considered that this installation condition has a highest heat transfer improvement when comparing with pressure drop. However heat gain of liquid at this condition was less than the other installation conditions of fin pitch on same height. Then, after establishing a proper minimum heat gain of liquid, actual production and experiment of collector will be conducted with fin height and pitch showing maximum JF factor and satisfying selected minimum heat gain of liquid on the basis of results of this study.

The Effects of Metathesis for Concentrating the Tocopherols from Soybean and Rice-bran Scum Oils (대두유 및 미강유의 찌꺼기유로부터 토코페롤의 농축을 위한 메타세시스 반응효과)

  • 안호근;문일식
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.449-454
    • /
    • 1995
  • The effects of metathesis for concentrating the tocopherols from soybean and rice-bran scum oils were studied by using the batch reactor under helium atmosphere. The contents of tocopherols in the scum oils decreased consticuously when heated under air atmosphere or when kept in hexane solution above 5 days even at room temperature. The sterols in the scum oils were removed by the mixed solvent method. Metathesis of the sterol-removed scum oils in hexane was performed over Re2O7/Al2O3 and WO3/Al2O3 catalysts, and the concentrate was obtained by distillation in vacuum at $190^{\circ}C$. The effect of metathesis was evaluated as relative ratio of ${\alpha}$-tocopherol in the concentrate to that in scum oil. The maximum ratio for both scum oils was obtained on 12.8%(w/w)$Re_2O_7/Al2O_3$ catalyst which formed effectively the active sites for metathesis by the reaction between the added tetramethyltin and $Re_2O_7$ on the surface of the catalyst. The optimum amount of the catalyst was 0.5g pre l0g scum oil, and the optimum reaction temperature was $25^{\circ}C$ for both scum oils. The metathesis was more effective in rice-bran scum oil than in soybean scum oil. These facts indicated that the tocopherols in the scum oils can be highly concentrated by applying metathesis.

  • PDF

The effect of heat to remove cement on implant titanium abutment and screw (시멘트 제거를 위해 가한 열이 임플란트 티타늄 지대주와 나사에 미치는 영향)

  • Yi, Hyo-Gyoung;Gil, Ki-Sung;Lee, Jung-Jin;Ahn, Seung-Geun;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.179-187
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effect of heat applied to disintegrate cement on the removal torque value and fracture strength of titanium abutment and abutment screw. Materials and methods: Implants, titanium abutments and abutment screws were prepared for each 20 piece. Implant abutments and screws were classified as the control group in which no heat was applied and the experimental group was heated in a vacuum furnace to $450^{\circ}C$ for 8 minutes and cooled in air. The abutments and screws were connected to the implants with 30 Ncm tightening torque at interval 10 minutes and the removal torque value was measured 15 minutes later. And the fracture strength of abutment screw was measured using universal testing machine. Results: The mean removal torque value was $27.84{\pm}1.07Ncm$ in the control group and $26.55{\pm}1.56Ncm$ in the experimental group and showed statistically significant difference (P < .05). The mean fracture strength was $731.47{\pm}39.46N$ in the control group and $768.58{\pm}46.73N$ in the experimental group and showed statistically no significant difference (P > .05). Conclusion: The heat applied for cement disintegration significantly reduced the removal torque value of the abutment screw and did not significantly affect fracture strength of the abutment screw. Therefore, in the case of applying heat to disintegrate cement it is necessary to separate the abutment screw or pay attention to the reuse of the heated screw. However further studies are needed to evaluate the clinical reuse of the heated screw.

Solid Flow Rate and Gas Bypassing with Operating Variables of J-valve in Multistage Annular Type Fluidized Beds (다단 환원형 유동층에서 J-valve의 운전변수에 따른 고체 흐름량 및 기체 우회)

  • Hong, Yoon-Seok;Kang, Gyung-Soo;Park, Joo-Sik;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.62-68
    • /
    • 2011
  • Hydrodynamic characteristics in multistage annular type fluidized bed (riser: $0.01{\times}0.025{\times}2.8m^3$, J-valve: $0.009{\times}0.015m^2$)were investigated. Glass beads ($d_p=101{\mu}m$, ${\rho}_b=1,590kg/m^3$, $U_{mf}=1.25{\times}10^{-2}m/s$, Geldart classification B) was used as a bed material. Accumulated weight by the electronic balance was measured to determine the solid flow rate in batch-type. In circulation condition, we measured the accumulated weight of particle transported from riser. At the steady state condition, solid circulation rate was calculated from time interval of the heated bed material passing between two thermocouples. Solid flow rate increased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 2.2 to 23.4 kg/s. However, mean residence time decreased with increasing inlet gas velocity ($1.2-2.6U_{mf}$) and the static bed height (z, 0.24-0.68 m) from 1,438 to 440 s. The solid holdup in the riser was determined by measuring pressure differences according to the riser height. These results showed a similar trend to that of simple exponential decay type except for the top section of the riser. To verify the gas bypassing from top bubbling beds to middle bubbling beds, $CO_2$ gas was injected by tracer gas in constant ratio, and then was measured $CO_2$ concentration in outlet gas by gas chromatography. Gas bypassing occurred below 2.6% which is negligible value.

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF

Effect of Heating by Nano-Carbon Fiber Infrared Lamps on Growth and Vase Life of Cut Roses and Heating Cost (나노탄소섬유 적외선등 난방이 절화장미의 생육과 수명 및 난방비에 미치는 영향)

  • Lim, Mi-Young;Ko, Chung-Ho;Son, Moon-Sook;Lee, Sang-Bok;Kim, Gil-Ju;Kim, Byung-Soo;Kim, Young-Bok;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The greatest and major cost for cut rose production during winter seasons in Korea is cost of heating the greenhouse. A study was conducted on a cost-efficient heating system to reduce expenses of cut rose growers in times of high energy prices. An infrared heating system utilizing radiant energy has an obvious advantage over other heating methods in that the energy is first used to raise temperatures of plants and other objects and subsequently that of the atmosphere, resulting in faster reaching to desired plant temperatures at a reduced heating cost. In this study the heating effect and heating cost saving of a nano-carbon fiber infrared heating system (NCFIHS) installed in cut rose greenhouses in Gimhae, Gyeongnam Province were analyzed comparatively. In addition growth, quality, and vase life of 'Orange Fresh' roses grown in greenhouses heated by NCFIHS against those grown in greenhouses heated by so called an electrical heating system. In greenhouses with a NCFlHS with a set point air temperature of $20^{\circ}C$, plant temperature was maintained at $1{\sim}2^{\circ}C$ higher than the air temperature, and temperatures of growing bed surface and root zone were maintained at $17{\sim}19^{\circ}C$ throughout cold winter nights. The cost for heating in NCFIHS was about 25 and 51% of that of an electrical heating system and a hot water heating system heated by petroleum, respectively. Growth of roses harvested in greenhouses with a NCFIHS was similar to those grown in greenhouses with an electrical heating system. However, cut roses with more intense petal and leaf colors and a longer vase life (fresh weight and amount of water uptake) were harvested in greenhouses with a NCFIHS as compared to those harvested in greenhouses with an electrical heating system.