• Title/Summary/Keyword: 공급 밸브

Search Result 229, Processing Time 0.031 seconds

축압기 유량조절용 Vortex 밸브의 유동 특성

  • 김영인;황영동;김성오;이기영;장문희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.17-22
    • /
    • 1996
  • 차세대원자로의 안전계통 성능향상을 위하여 축압기 설계에서 채택하고 있는 피등적 유량조절 장치인 vortex 밸브의 특성을 분석하였다. 단순화된 해석모델을 이용하여 vortex chamber의 유동 pattern을 분석하였으며 vortex 밸브의 성능에 중요한 영향을 미치는 기하학적 인자들의 영향 유동모드 전환시 주유량이 공급되는 수관의 수위거동 특성을 분석하였다. 또한 3차원 모의가 가능한 FLUENT 코드를 사용하여 vortex chamber의 유동장을 해석하여 vortex 밸브의 유동특성을 분석하였다.

  • PDF

Study on the improvement in Cv of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 유량계수 향상에 관한 연구)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, in the steady operational state, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the combustion chamber. Concerning the development of MOV, TM(Technology Model) has been manufactured and normal operations of the valve have been verified. However, the Cv of TM has been proved to be too low as compared with a design specification value. Therefore, CFD analysis have been performed by modification of the configurations of TM in order to increase sufficiently Cv of EM(Engineering Model), which is the following model of TM. The modifications of TM configurations such as partial scale-up of valve, increase of stroke length, and outlet angle of 120o would result in a considerable augmentation of Cv. It has been verified by flow capacity tests that the improved Cv of EM is min. 212, which is higher than Cv of TM, 161 by about 32%.

  • PDF

Application of Valve Transfer Algorithm for Turbine Control Valve in Power Plant (발전소에서 터빈 제어밸브의 전환운전 알고리듬 구현 및 적용)

  • Woo, Joo-Hee;Jeong, Chang-Ki;Kim, Jong-Ahn;Kim, Byung-Chul;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2613-2615
    • /
    • 2005
  • 증기터빈 발전소에서 터빈제어밸브는 운전중 적절히 개도를 조절하여 보일러에서 공급되는 유량을 조절하여 터빈속도 및 발전기의 전기적 출력을 제어할 수 있도록 해준다. 이러한 터빈제어밸브는 4개로 구성되어 있으며, 운전중 최적의 발전효율을 얻기 위해 저부하에서는 4개의 제어밸브가 동일하게 조절되다가 밸브 전환 운전을 완료한 후 4개의 밸브가 주어진 특성에 따라 각기 조절되어야 할 필요성이 있다. 이때 수행되는 과도기적인 운전절차인 밸브 전환운전시 발전기 출력 등의 변화가 없어야 한다. 본 논문에서는 밸브전환 운전시 발전기 출력을 일정하게 유지하기 위하여 고압터빈 1단 압력을 궤환받아 발전기 출력을 보상하는 제어알고리듬을 제시하고 실제 발전소에 적용한 결과를 소개하고자 한다.

  • PDF

Study on the performance improvement of a Main Oxidizer shut-off Valve Using Computer Aided Structural Analysis (전산 구조해석을 이용한 산화제 개폐밸브 성능향상에 관한 연구)

  • Kim, Do-Hyung;Bae, Young-Woo;Hong, Moon-Geun;Yoo, Jae-Han;Kim, Eun-Soo;Jang, Ki-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.111-114
    • /
    • 2010
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the steady operational state. To modify the middle flange and rip of inlet valve design by Computer Aided Structural Analysis for improvement of EM core functions. In result, it has been verified to improve performance of EM by tests.

  • PDF

달착륙선의 전력시스템 개념설계와 지상시험모델용 추력기 밸브구동 전원장치 개발

  • Jang, Seong-Su;Ju, Gwang-Hyeok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.196.2-196.2
    • /
    • 2012
  • 본 논문은 달착륙선의 개념설계를 위하여 고려한 전력시스템의 설계와 달착륙선의 지상시험모델용 추력기 밸브구동 전원장치 개발에 대해 기술하였다. 달착륙선의 임무특성을 고려하여 전력시스템의 구조를 검토하고, 극한의 온도환경에서 달착륙선의 임무수행을 위하여 필요한 전력에너지를 충분히 공급할 수 있도록 태양전지 배열기와 배터리의 용량, 그리고 전장품의 용량을 설계하였다. 특히 경량의 달착륙선 개발을 위하여 고효율의 태양전지를 이용한 태양전지 배열기와 리튬-이온 배터리를 검토하였다. 극한의 우주환경에서 태양전지배열기의 동작특성을 검토하고 생성될 수 있는 최대 전력을 분석하여 최적의 태양전지 배열기의 면적을 분석하고, 장시간의 월식을 고려하여 배터리의 방전특성에 따른 배터리의 전압특성을 검토하였다. 그리고 달착륙선의 전력시스템 개념설계의 타당성 검토를 위하여 유럽에서 개념설계 중인 달착륙선의 전력시스템 사양과 용량에 대해 비교검토를 수행하였다. 현재 개발중인 지상검증모델용 달착륙선의 전력시스템 설계와 추력기 밸브구동 전원장치의 개발에 관해 기술하였다. 지상검증용 전력시스템은 태양전지배열기의 장착 없이 배터리의 전력만을 사용하여 지상검증모델용 달착륙선의 부하에 전력을 공급할 수 있도록 설계되었다. 달착륙선 지상시험모델의 비행시간과 임무에 따른 부하특성을 고려하여 상용 리튬-이온 배터리의 용량을 선정하였으며, 부하의 전력을 고려하여 간단한 보호회로를 설계하였다. 그리고 지상검증용 전원시스템은 추력기의 밸브구동을 위한 추력기 밸브구동 전원장치, DC/DC 컨버터 전원 모듈, 모니터링 모듈, 그리고 위급상황에서 전원을 차단하기 위한 "Emergency STOP" 모듈로 구성되어 있다.

  • PDF

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

Optimal placement of isolation valves in water distribution networks based on segment analysis (단수구역 해석을 이용한 상수관망시스템 내 최적 밸브위치 결정)

  • Lim, Gabyul;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.291-300
    • /
    • 2019
  • If pipes are damaged in a water distribution network (WDN), adjacent valves are closed to isolate the pipes for repair. Due to the closed valves, parts of WDN are isolated from water supply sources. The isolated area is divided into Intended Isolation Area (IIA) and Unintended Isolation Area (UIA). The IIA occurs by intention to isolate the damaged pipe, while UIA is unintentionally disconnected from the sources due to IIA. Thus, the extension of isolated area and suspended flows are mainly affected by number and location of installed valves in WDN. In this study, optimization models were developed to determine optimal valve locations in WDN. In a single-objective model, total water supply suspension is minimized, while a multi-objective model intends to simultaneously minimize the suspended flow and valve installation cost. Optimal valve placement results obtained from both models were compared and analyzed using a sample application network.

Improvement of Valve Transfer Algorithm for Turbine Control Valve in Power Plant (발전소에서 터빈 제어밸브의 전환운전 알고리듬 개선)

  • Woo, Joo-Hee;Jeong, Chang-Ki;Kim, Jong-Ahn;Kim, Byung-Chul;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1873-1874
    • /
    • 2006
  • 증기터빈 발전소에서 터빈제어밸브는 운전중 적절히 개도를 조절하여 보일러에서 공급되는 유량을 조절하여 터빈속도 및 발전기의 전기적 출력을 제어할 수 있도록 해준다. 이러한 터빈제어밸브는 4개로 구성되어 있으며, 운전중 최적의 발전효율을 얻기 위해 저부하에서는 4개의 제어밸브가 동일하게 조절되다가 밸브 전환운전을 완료한 후 4개의 밸브가 주어진 특성에 따라 각기 조절되어야 할 필요성이 있다. 대상 발전소에서 시행하고 있는 운전절차중 하나인 밸브전환 운전은 발전기 출력의 변화가 수반되며 이를 최소화하기 위해 고압터빈측의 1단 압력을 궤환하여 보상하는 알고리듬을 사용하고 있다. 사용중에 발전기 출력변화가 발생되어 이를 개선하기 위해 적용되는 알고리듬을 보완하여 실제 발전소 현장에 적용한 결과를 소개하고자 한다.

  • PDF

Opening Characteristics of a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 개방 특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.11
    • /
    • pp.989-997
    • /
    • 2017
  • We study opening transient responses of a self-sustainable poppet valve, which is usually used for the main oxidizer shut-off valve of liquid rocket engines. In order to perform numerical analysis, a pneumatic supply system was simulated as an orifice with a diameter of 3.2 mm and the equations of motion of valve moving part were derived. For the validation of the study, a comparison of numerical predictions and experimental results has been done. As one of the practical applications of this study, the employment of an orifice in a high pneumatic pressure has been presented to control the valve opening time.

Opening Characteristics of a Main Oxidizer Shut-off Valve at Different Valve Inlet Pressures (밸브 입구 압력 변화에 따른 연소기 산화제 개폐밸브 열림 특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.801-807
    • /
    • 2020
  • Opening characteristics of a main oxidizer shut-off valve at different valve inlet pressures have been experimentally investigated. The pilot pressure at the moment of the valve opening increases linearly with increasing the valve inlet pressure and the increased pilot pressure reduces the valve travel time. As the pilot pressure increases at the moment of valve opening, the time to start opening the valve is delayed resulting in increasing the valve opening time. With the increment of the valve inlet pressure, the valve opening time is mainly determined by the time required for the pilot pressure to start opening the valve. Therefore the design of a pilot gas supply system can readily control the valve inlet pressure at the valve opening as well as the amount of oxidizer supplied to a combustion chamber during the engine startup.