• Title/Summary/Keyword: 공급장치

Search Result 1,859, Processing Time 0.03 seconds

Assessment of CO2 Fertilization Captured in Thermoelectric Power Plant on Leafy Vegetables Grown in Greenhouse (화력발전소 포집 CO2를 이용한 시설 엽채류 시비효과 평가)

  • Jeong, Hyeon Woo;Hwang, Hee Sung;Park, Jeong;Yoon, Seong Ju;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.423-431
    • /
    • 2022
  • Due to increase of interest in 'carbon neutrality', attempts at agricultural use of CO2 are increasing. In this study, we used the dry-ice made by CO2 as by-product in thermoelectric power plant on CO2 fertilization for production of leafy vegetable in greenhouses. The dry-ice was supplied on three leafy vegetable farms (Allium tuberosum Rottl. ex Spreng, Aster scaber, and Oenanthe stolonifera DC.) located in Hadong, Gyeongsangnamdo. Two greenhouses were used in each leaf vegetable crops, one greenhouse used as the control (non-treatment), other greenhouse used as supplied CO2. For CO2 fertilization, a gas sublimated from dry ice was supplied to the greenhouse using a specially designed prototype supply machine. A. tuberosum greenhouse has no difference of CO2 concentration between the control, and CO2 fertilization and shown high CO2 concentration both greenhouses. However, the CO2 concentrations in A. scaber and O. stolonifera greenhouses were increased in CO2 fertilization treatment. The growth of A. scaber and O. stolonifera were increased in CO2 fertilization, and the yield also increased to 36% and 25% than the control, respectively. As a result of economic analysis, the A. scaber has increase of income rate, however A. tuberosum and O. stolonifera has decreased income rate. Thus, the use of the dry-ice made by CO2 as by-product in thermoelectric power plant has possibility to increase productivity of the leafy vegetable in greenhouse and have agricultural use value.

Seasonal Variations of Particle Fluxes in the Northeastern Pacific (북동태평양 심해에서 관측된 퇴적물 입자 플럭스의 계절적 변동)

  • Kim, Hyung-Jeek;Kim, Dong-Seon;Hyeong, Ki-Seong;Kim, Kyeong-Hong;Son, Ju-Won;Hwang, Sang-Chu;Chi, Sang-Bum;Kim, Ki-Hyun;Khim, Boo-Keun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.3
    • /
    • pp.200-209
    • /
    • 2008
  • Particle fluxes were measured with a time-series sediment trap from July 2003 to June 2005 at the St. KOMO(KOMO; Korea Deep-Sea Environmental Study Long-Term Monitoring Station, $10^{\circ}30'N,\;131^{\circ}20'W$) in the northeastern Pacific. Total mass fluxes at a depth of 4,960 m showed distinct seasonal variations with high values in the winter(December-February) and spring(March-May) and low values in the summer(June-August) and fall(September-November). Biogenic origin fluxes also displayed distinct seasonal variations similar to total mass fluxes. Particularly, calcium carbonate fluxes in winter and spring were more than two times greater than those in summer and fall. The prominent seasonal variations of total mass and biogenic fluxes were closely related with the seasonal changes of primary production in the surface waters; in winter and spring, primary production increased due to the enhanced supply of nutrients below the surface mixed layer by strong wind and less stratification, whereas it decreased as a result of the less supply of nutrient by reduced wind speed and strong stratification in summer and fall. The seasonal variations of total mass and biogenic fluxes in this study were higher than the differences of total mass and biogenic fluxes caused by the environmental changes such as El $Ni\tilde{n}o$ and La $Ni\tilde{n}a$ events in the previous studies. In order to understand the effects of El $Ni\tilde{n}o$ and La $Ni\tilde{n}a$ on the particle flux, therefore, the seasonal variation of particle flux in the northeastern equatorial Pacific needs to be well defined.

Speed-up Techniques for High-Resolution Grid Data Processing in the Early Warning System for Agrometeorological Disaster (농업기상재해 조기경보시스템에서의 고해상도 격자형 자료의 처리 속도 향상 기법)

  • Park, J.H.;Shin, Y.S.;Kim, S.K.;Kang, W.S.;Han, Y.K.;Kim, J.H.;Kim, D.J.;Kim, S.O.;Shim, K.M.;Park, E.W.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.153-163
    • /
    • 2017
  • The objective of this study is to enhance the model's speed of estimating weather variables (e.g., minimum/maximum temperature, sunshine hour, PRISM (Parameter-elevation Regression on Independent Slopes Model) based precipitation), which are applied to the Agrometeorological Early Warning System (http://www.agmet.kr). The current process of weather estimation is operated on high-performance multi-core CPUs that have 8 physical cores and 16 logical threads. Nonetheless, the server is not even dedicated to the handling of a single county, indicating that very high overhead is involved in calculating the 10 counties of the Seomjin River Basin. In order to reduce such overhead, several cache and parallelization techniques were used to measure the performance and to check the applicability. Results are as follows: (1) for simple calculations such as Growing Degree Days accumulation, the time required for Input and Output (I/O) is significantly greater than that for calculation, suggesting the need of a technique which reduces disk I/O bottlenecks; (2) when there are many I/O, it is advantageous to distribute them on several servers. However, each server must have a cache for input data so that it does not compete for the same resource; and (3) GPU-based parallel processing method is most suitable for models such as PRISM with large computation loads.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

Growth of the Tilapia, Oreochromis niloticus, in the Closed Aquaculture System (폐쇄식 사육 장치내에서 틸라피아(Oreochromis niloticus)의 성장)

  • KIM In-Bae;SON Maeng-Hyun;MIN Byung-Suk
    • Journal of Aquaculture
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 1991
  • A series of rearing experiments were conducted to determine the growth rates and feed conversion efficiencies of tilapia in accordance with body size or age in nearly total closed system glass aquariums ($270\;\ell$ each in water volume) and concrete tanks ($4000\;\ell$) from April 10 to October 16, 1987. The fish used for the experiments was a Japanese strain of Oreochromis niloticus, and the size of the fish ranged from 7 g to more than 1,000 g in body weight. The starting stocking rates for each experimental lot were 10 to 20 kg in the glass aquarium ($3.7{\%}$ to $7.4{\%}$ of water volume) and 200 kg in the concrete tank ($5{\%}$ of water volume). A single experimental rearing term was 14 days with slight variations on occasions. Water temperature was designed to be kept at $26^{\circ}C$ but slight fluctuations were inevitable. Dissolved oxygen level was designed to be maintained at around $3\;mg/\ell$, but it also showed some variations. The ammonia level in the glass aquarium section once reached up to $18\;mg/\ell$, but generally remained at around $4\;mg/\ell$, and in the concrete tank section it was maintained at around $1\;mg/ell$. The feed was composed of mainly soybean meal with a small amount of fish meal as the protein source, and the crude protein content was about $32{\%}$. Mean daily growth rate was $3.5{\%}$ of body weight with 0.9 in food conversion ratio in the glass aquarium when the mean weight of fish was around 10 g with gradually reduced performances as the fish grew bigger. When the mean weight was 800 g, mean daily growth rate was $0.5{\%}$ with about 1.5 in food coversion for fish in the glass aquarium, and $0.8{\%}$ and 1.6 for fish in the concrete tank, respectively. According to the mean growth rate obtained from this experiment, it was calculated that the fish reared in the concrete tank require 223 days from 50 g to reach 1,000 g which is the ideal size for market in Korea, at the conditions provided as above, and 302 days from 10 g fingerlings to 800 g fish in the glass aquarium conditions of the closed recirculating water system.

  • PDF

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

Study of CO2 Carbonation-Regeneration Characteristics of Potassium-Based Dry Sorbents According to Water Vapor Contents of Inlet Gas and Regeneration Temperature in the Cycle Experiments of Bubbling Fluidized-Bed Reactor (회분식 기포유동층 반응기에서 K-계열 건식흡수제의 주입수분농도 및 재생반응온도에 따른 CO2 흡수-재생 반응특성 연구)

  • Park, Keun-Woo;Park, Yeong Seong;Park, Young Cheol;Jo, Sung-Ho;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.349-354
    • /
    • 2009
  • In this study, a bubbling fluidized-bed reactor was used to study $CO_2$ capture from flue gas using a potassium-based dry sorbent. A dry sorbent, manufactured by the Korea Electric Power Research Institute, consists of 35% of $K_2CO_3$ for $CO_2$ absorption and 65% of supporters for mechanical strength. $H_2O$, a reactant of the carbonation reaction, was supplied in the reactor as a form of saturated water vapor at a given temperature. The experiment of the regeneration reaction was performed by raising up to a given temperature using $N_2$ as a fluidization gas. It was indicated that sorption capacity and regenerability of dry sorbents showed high-efficiency at $1.97\;mol\;H_2O/mol\;CO_2$ and $400^{\circ}C$, respectively. The regenerated sorbent samples were analyzed by TGA to confirm the extent of the reaction. When the regeneration temperature was $150^{\circ}C$, the regenerability of dry sorbents was about 60%, which was capable of applying those sorbents to a two-interconnected fluidized-bed reactor system with continuous solid circulation. The results obtained in this study can be used as basic data for designing and operating a large scale $CO_2$ capture process with two fluidized-bed reactors.

Application of Dynamic Reaction Cell - Inductively Coupled Plasma Mass Spectrometry for the Determination of Calcium by Isotope Dilution Method (반응셀 유도결합플라스마 질량분석분석기를 이용한 칼슘 동위원소비율의 측정과 동위원소희석법의 적용)

  • Suh, Jungkee;Yim, Yonghyeon;Hwang, Euijin;Lee, Sanghak
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.417-426
    • /
    • 2002
  • Inductively Coupled Plasma Dynamic Reaction Cell Quadrupole Mass Spectrometry (ICP-DRC-QMS) was characterized for the detection of the six naturally occurring calcium isotopes. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio. This experiment shows that the potentially interfering ions such as $Ar^+$, ${CO_2}^+$, ${NO_2}^+$, $CNO^+$ at the calcium masses m/z 40, 42, 43, 44 and 48 were removed by flowing $NH_3$ gas at the rate of 0.7 mL/min $NH_3$ as reactive cell gas in the DRC with a RPq value (rejection parameter) of 0.6. The limits of detection for $^{40}Ca$, $^{42}Ca$, $^{43}Ca$, $^{44}Ca$, and $^{48}Ca$ were 1, 29, 169, 34, and 15 pg/mL, respectively. This method was applied to the determination of calcium in synthetic food digest samples (CCQM-P13) provided by LGC for international comparison. The isotope dilution method was used for the determination of calcium in the samples. The uncertainty evaluation was performed according to the ISO/GUM and EURACHEM guidelines. The determined mean concentration and its expanded uncertainty of calcium was ($66.4{\pm}1.2$) mg/kg. In order to assess our method, two reference samples, Riverine Water reference sample (NRCC SLRS-3) and Trace Elements in Water reference sample (NIST SRM 1643d), were analyzed.

Effect of the Particle Size and Unburned Carbon Content on the Separation Efficiency of Fly ash in the Countercurrent Column Flotation (向流컬럼浮選機에서 石炭灰의 크기 및 未燃炭素 含量이 分離特性에 미치는 영향)

  • 이정은;이재근
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.36-44
    • /
    • 2000
  • Fly ash was composed of the unburned carbon and mineral particles. The former was able to attach on the bubbles, while the latter was not. Therefore, it was possible to separate the unburned carbon and the mineral from fly ash using the froth flotation process. This study was carried out to evaluate the separation efficiency as a function of the ny ash particle properties in the column flotation. Separation efficiency was analyzed for various size fraction of -38 fm,38~125 fm and 1125 W, and for various fly ash samples containing 7, 11, and 20 wt% unburned carbon. For the size fractions of -38 fm containing 7 wt% unburned carbon, separation efficiency was 86ft, whereas separation efficiency was found to be 74% for the size fraction of +125$\mu\textrm{m}$ containing 20 wt% unburned carbon. The results indicated that separation efficiency increased with the decrease in the particle size and the unburned carbon content of the fly ash.

  • PDF