• Title/Summary/Keyword: 공극비

Search Result 793, Processing Time 0.028 seconds

Earth Hummocks on the Crater Floor of Baegnokdam at Mt. Halla (한라산 백록담 화구저의 유상구조토)

  • 김태호
    • Journal of the Korean Geographical Society
    • /
    • v.36 no.3
    • /
    • pp.233-246
    • /
    • 2001
  • Topography and soil characteristics of earth hummocks are examined in the summit crater of Mt. Halla in order to evaluate their morphoclimatic significance as an indicator of a periglacial environment. The hummocks are generally oval in outline, and they have a diameter of 42 to 200 cm and a height of 9 to 27 cm Seventeen hummocks are distributed In a 5$\times$5 m quadrat at an interval of 20 to 40 cm Excavation reveals the cryoturbated soil profiles which consist of upper dark brown layer and lower brown layer. The dark brown layer has 61.8% total clay and silt content, implying Its high frost susceptibility Earth hummocks have the dry density of 0.761 to 1.009 g/㎤ the void ratio of 1420 to 2.008, and the moisture content of 24.2 to 68.8% by weight, respectively. The hummocky soils become compacted and desiccated downward. Earth hummocks are frozen as a hard solid mass during winter and early spring, and freezing fronts reach about 45 cm below their apices. The layer with high lute content appears in the upper horizon of dark brown soil. but Ice lenses are not so much segregated The moisture content of hummocky soils generally increases up to 73.9 to 118.80% for dark brown layer and 49.9 to 82.8% for brown layer during thins period Because the cohesive soil of earth hummocks indicates 72.8% of the moisture content as a liquid limit, the dark brown layer is highly fluid and consequently subject to cryoturbation processes.

  • PDF

A Study on the Prediction of Maximum Dry Density and Optimum Moisture Content in Soil Compaction (흙의 다짐에 있어서 최대건조밀도(最大乾燥密度)와 최적함수비(最適含水比)의 추정(推定)에 대(對)하여)

  • Kang, Yea-Mook;Cho, Seung-Seup;Kim, Jae-Young
    • Korean Journal of Agricultural Science
    • /
    • v.3 no.2
    • /
    • pp.207-213
    • /
    • 1976
  • In order to obtain the prediction of the maximum dry density and the optimum moisture content of soil without soil moisture test, compaction test results from 157 different places either under construction or already completed were analyzed. The analyzed results were as follow The relationship between the maximum dry density and the optimum moisture content of the soil showing a correlation coefficient of 0.96 indicated that there was a high correlation between them. From the above relationship we obtained the equation, ${\gamma}_{dmax.}={\frac{1}{0.4193+0.00937W_{opt.}}$ Equation between the optimum moisture content and the maximum wet density of the soil was $W_{opt.}={\frac{0.4193{\gamma}_{tmax.}}{0.937_{\gamma}_{tmax.}-0.01}$, and the values of the optimum moisture content being predicted with the maximum wet density of the soil showed a little difference between those and tested values. The values of the maximum dry density being predicted with the moisture content estimated by the maximum wet density of the soil were within the range of ${\pm}5%$ of its tested values. The relationship between the dry density and the void ratio showed a high correlation between them (${\gamma}=0.9706$). From the above relationship, we obtained the equation, ${\gamma}_{dmax.}={\frac{1}{0.3938+0.3426e}}$.

  • PDF

Physical and mechanical properties of volcanic glass in the Samho area, South Korea (삼호지역에 분포하는 유리질화산암에 대한 물리적$\cdot$역학적 특성)

  • Kang Seong-Seung;Lee Heon-Jong;Kang Choo-Won;Kim Cheong-Bin
    • Tunnel and Underground Space
    • /
    • v.15 no.3 s.56
    • /
    • pp.223-227
    • /
    • 2005
  • The physical and mechanical properties of volcanic glass, which is distributed in the Samho area, South Korea were studied. Laboratory rock tests were carried out in order to obtain the various properties of rocks. Specific gravity, water content, absorption, porosity and wave velocity were measured for the physical properties. Uniaxial and triaxial compressive tests, Brazilian test and point load test were also performed for the mechanical properties. The tests of volcanic glass revealed that the apparent specific gravity, water content and absorption were 2.28, $1.67\%$ and $1.72\%$, respectively. Porosity $(3.87\%)$ was lower, whereas P-wave velocity (5330m/s) and S-wave velocity (2980 m/s) were relatively higher. Brazilian tensile strength ot 7.2MPa, and point load strength of 2.6MPa were among the mechanical properties of the rock. Uniaxial compressive strength (62.4MPa) estimated ken point load strength was very closed to the value (66.0MPa) from the uniaxial compressive test. Young's modulus and Poisson's ratio were E=43.2 GPa and v=0.28, respectively. Drawing the tangent line to Mohr-Coulomb failure criterion showed the cohesion of 20.1MPa and internal fraction angle of $28.6^{\circ}$.

Contact-less Conveyance of Conductive Plate by Controlling Permalloy Sheet for Magnetic Shield of Air-gap Magnetic Field from Magnet Wheels (마그네트 휠의 공극 자기장 차폐판 조절에 의한 도전성 평판의 비접촉 반송)

  • Jung, Kwang-Suk;Shim, Ki-Bon;Lee, Sang-Heon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.109-116
    • /
    • 2010
  • The magnet wheel which generates on its interfacing conductive part a repulsive force and a traction torque by rotation of permanent magnets is used to manipulate the conductive plate without mechanical contact. Here, the air-gap magnetic field of the magnet wheel is shielded partially to convert the traction torque into a linear thrust force. Although a magnitude of the thrust force is constant under the fixed open region, we can change the direction of force by varying a position of the shield sheet. So, the spatial position of conductive plate is controlled by not the force magnitude from each magnet wheel but the open position of shield sheet. This paper discusses non-contact conveyance system of the conductive plate using electromagnetic forces from multiple magnet wheels.

Hydraulic Properties of Duksan Hot-spring Area (덕산온천 지역의 수리적 성질)

  • 함세영;조병욱;성익환
    • The Journal of Engineering Geology
    • /
    • v.9 no.2
    • /
    • pp.101-118
    • /
    • 1999
  • The pumping test analysis on 28 pumping test data in Duksan hot-spring area was performed using the fractal model, the leaky fractal model, and the steady-state dual-porosity fractal model. The fractional flow dimension 1.9 or 2.0 was determined in the central put of the hot spring and the fractional flow dimension 1.5-1.7 in the marginal area. For the flow dimension 2.0, the correlation between the transmissivity and the productivity index by the aquifer loss was much better than that between the transmissivity and the specific yield by the total drawdown. On the other hand, for the flow dimension 1.9, the correlation between the generalized transmissivity and the productivity index was very similar to that between the generalized transmissivity and the specific yield.

  • PDF

Development of Polymer-Concrete Composite(I) - Physical Properties of Polymer-Cement Concrete Composites - (폴리머-콘크리트 복합재료 개발(I) - 폴리머-시멘트 콘크리트의 물성 -)

  • Hwang, Eui-Hwan;Kil, Deog-Soo;Oh, In-Seok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.979-984
    • /
    • 1997
  • Test specimens of polymer-cement concrete composites were prepared using styrene-butadiene rubber(SBR) latex, ethylenevinyl acetate(EVA) and polyacrylic ester(PAE) emulsions as polymer dispersions in cement modified system at constant slump($10{\pm}0.5cm$), then compressive and flexural strengths water absorption, pore size distribution, and microstructures were investigated. Compressive and flexural strengths of these composites were remarkably improved with an increase of polymer-cement ratio. These composites had a desirable pore size distribution against frost damage due to a small capillary pore volume. Continuous polymer film was able to form in higher than 15% of polymer cement ratio.

  • PDF

A Numerical Study on Nonlinear Flow in Porous Medium (다공성 매질에서 비선형 흐름에 대한 수치적 연구)

  • Jeong, Woo Chang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.384-384
    • /
    • 2017
  • In this study, the numerical investigation of nonlinear flow in a porous medium was carried out. The applied numerical model is ANSYS CFX which is a three-dimensional fluid dynamic model, and the verification of this model was carried out by using the experimental data obtained from Mayer et al works(2011). The experimental and numerical results of velocity and Reynolds number-friction coefficient relationship show relatively a good agreement. Based on the experimental results, we analysed numerically the velocity and Reynolds number-friction coefficient relationship with the variation of permeability, dynamic viscosity and porosity and quantitatively the variation by applying the best curve fitting for each case.

  • PDF

Application Techniques of 2D-Resistivity Structure for Estimation of Inferred Fracture Zone in Weathered Slope (풍화사면에서의 추정파쇄대 평가를 위한 2차원 전기비저항 구조도 적용 기법)

  • Kim, Jae-Hong;Park, Chal-Sook;Lee, Hyun-Jae;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.323-330
    • /
    • 2009
  • Electrical resistivity survey is applied for estimation of inferred fault and fractured zone in civil engineering and environment field. While 15 m diameter and 3 lines tunnels are excavated. It is recognized that core stone and fractured zone is existed in the weathered slope of the entrance to a tunnel. To make confirmation geological characteristics, dipole-dipole electric resistivity survey was carried out in weathered slope of the entrance to a tunnel. Core stone distribution and fracture zone characteristics are estimated by reverse analysis and 2D-resistivity structure using FDM.

Laboratory study on the electrical resistivity characteristics using an artificial agar specimen with clay minerals (점토광물을 함유하는 한천인공시료를 이용한 전기비저항 특성에 관한 실험적 연구)

  • Park, Mi-Kyung;Park, Sam-Gyu;Kim, Hee-Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.65-70
    • /
    • 2005
  • A low resistivity zone is found in many places such as a fractured fault zone, weathered zone and aquifer. The electrical resistivity is influenced mainly by pore fluid as well as the clay mineral types and contents, Hence, it is very important to understand the relationship between the electrical resistivity and clay contents associated with the low resistivity zone for geotechnical applications such as civil engineering. This study examines the characteristics of clay mineral types and contents to electrical resistivity through sample measurements, and proposes an expression relating the resistivity and clay content. The electrical resistivity is measured for an artificial agar specimen with clay minerals instead of a natural rock. The clay minerals used are Kaolinite and Montmorillonite. Montmorillonite shows remarkably lower resistivity than Kaolinite, although its clay content is fewer than that of Kaolinite. Also, the proposed expression shows a good correlation coefficient as high as 0.89 or more in all clay minerals.

  • PDF

No-Tillage Agriculture of Korean-Style on Recycled Ridge II. Changes in Physical Properties : Water-Stable Aggregate, Bulk density, and Three Phase Ratio to Retain Water at Plastic Film Greenhouse Soil in No-Tillage System (두둑을 재활용한 한국형 무경운 농업 II. 시설 무경운 토양의 물리적 특성 : 입단과 용적밀도 및 삼상변화)

  • Yang, Seung-Koo;Shin, Gil-Ho;Kim, Sun-Kook;Kim, Hee-Kwon;Kim, Hyun-Woo;Jung, Woo-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.24 no.4
    • /
    • pp.719-733
    • /
    • 2016
  • This study was carried out to investigate the effect of no-tillage on sequential cropping supported from recycling of first crop ridge on the productivity of crop and physical properties of soil under green house condition. This study is a part of "No-tillage agriculture of Korea-type on recycled ridge". From results for distribution of soil particle size with time process after tillage, soil particles were composed with granular structure in both tillage and no-tillage. No-tillage soil in distribution of above 2 mm soil particle increased at top soil and subsoil compared with tillage soil. Tillage and one year of no-tillage soil were not a significant difference at above 0.25 mm~below 0.5 mm, above 0.5 mm~below 1.0 mm, and above 1.0 mm of water-stable aggregate. Two years of no-tillage soil was significantly increased by 8.2%, 4.5%, and 1.7% at above 0.25 mm~below 0.5 mm, above 0.5 mm~below 1.0 mm, and above 1.0 mm of water-stable aggregate, respectively, compared with one year of no-tillage. Bulk density of top soil was $1.10MG\;m^3$ at tillage and $1.30MG\;m^3$ at one year of no-tillage. Bulk density of top soil was $1.14MG\;m^3$ at two years and $1.03MG\;m^3$ at three years of no-tillage, respectively. Bulk density of subsoil was a similar tendency. Solid phase ratio in top soil and subsoil was increased at one year of no-tillage compared with tillage soil, while soil phase ratio decreased at two and three years of no-tillage. Pore space ratio in tillage top soil (58.5%) was decreased by 8.5% at compared with no-tillage soil (51.0%). Pore space ratio was 56.9% and 61.2% at two and three years of no-tillage soil, respectively. Subsoil was a similar tendency. Gaseous phase ratio was decreased at one year of no-tillage soil, and increased at two and three years of no-tillage soil compared with tillage soil. Liquid phase ratio in top soil was increased at one year of no-tillage (28.3%), and decreased at two years (23.4%) and at three years (18.3 %) of no-tillage soil compared with tillage soil (24.2%). Subsoil was a similar tendency. Liquid phase ratio in subsoil was increased than top soil.