Dose Distribution Comparison between Arc Radiation Therapy and Tomotherapy (아크치료기법과 토모테라피치료의 선량분포 비교)

  • Kim, Ji-Yoon;Lee, Seung-Chul;Cheon, Geum-Seong;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.723-730
    • /
    • 2021
  • This study tries to compare dose distribution between arc radiation therapy and Tomotherapy, which are main radiation therapy modalities. The subjects of this study are lung cancer patients. For planning target volume (PTV), a dose of 60.0 Gy was set as a basis. The PTVmean of Arc was 61.04 Gy, and that of Tomotherapy was 58.50 Gy. The total lung capacities of Arc and Tomotherapy were 3.0 Gy and 4.24 Gy, respectively. The mean heart doses of Arc and Tomotherapy were 0.13 and 0.34, respectively; the mean trachea dose of Arc and Tomotherapy were 1.35 and 2.58, respectively; the mean esophagus dose of Arc and Tomotherapy were 0.41 and 0.86, respectively; the mean spinal cord dose of Arc and Tomotherapy were 3.65 and 4.68, respectively. With regard to the appropriateness of therapeutic effect in DHV, both modalities seemed appropriate. Tomotherapy protected normal tissues better than Arc radiation therapy. In Tomotherapy, patients need to have treatment long in a limited space. If such a point is overcome, Tomotherapy is better. Otherwise, Arc radiation therapy can be applied. This study was conducted with treatment planning images. Therefore, the results of this study are different from actual treatment results. If more research is conducted to overcome the limitation, the effects of radiation therapy are expected to increase further.

Bone Density Spatial Distribution of Radiation Dose Measurement (양방사선 골밀도 측정 장치의 공간산란선량분포측정)

  • Kim, Seon-Chil;Won, Do-Yeon;Park, Chang-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

A Preliminary Study of Virtual-micro Intensity Modulated Radiation Therapy (가상 미세 세기조절방사선치료(Virtual micro-IMRT;VMIMRT) 기법의 임상 적용을 위한 예비적 연구)

  • 김상노;조병철;서택석;배훈식;최보영;이형구
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.32-36
    • /
    • 2002
  • For Intensity Modulated Radiation Therapy(IMRT), the spatial resolution of intensity map(IM) is limited by the width of multi-leaf collimator, which would make an effect on the conformity of the target, as well as organs at risk. Several Methods are suggested to increase the spatial resolution, which can be categorized by the hardware-dependent technique and the software-based technique. However the best solution might be to make the width of MLC finer. it has several obstacles in the respects of technical difficulty and cost. This preliminary study is designed to investigate the clinical effectiveness of the virtual-micro IMRT(VMIMRT) technique, one of the software-based technique. A particular intensity map was created, which has 42$\times$54 pixel dimension ,0.5cm pixel size and 15 intensity levels. Using this intensity map, segment fields of IMRT were generated with 1$\times$lcm, 0.5$\times$1cm, 0.5$\times$0.5cm(VMIM) beamlet size, respectively As results, we found that there was no evidence of improvement for VMIMRT, compared with the 0.5$\times$lcm beamlet size which can be delivered by 1cm width MLC. The reason seems to be due to the constraint of VMIMRT. Further study is required to prove the benefit of the VIMRT in clinical case like head and neck cancer, where is expected that higher resolution than 1cm is necessary.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Electrical Characteristics on MOS Structure with Irradiation of Radiation (방사선이 조사된 MOS구조에서의 전기적 특성)

  • 임규성;고석웅;정학기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.644-647
    • /
    • 2001
  • The investigations were discussed on the radiation effects of the electrical properties to the p-type MOS capacitors, which were irradiated by cobalt-60 gamma ray sources. The characteristics of capacitance-bias voltage(C-V) and of dielectric dissipation tarter-bias voltage(D-V) on the capacitors were measured at 1 [MHz] frequency. The microscopic behaviors of spate charges in oxide and silicon-silicon dioxide(Si- $SiO_2$) interface were investigated from the experimental data. The C-V characteristics are statical and convenient for the evaluation of the steady state behavior of carriers and interface states characteristics. While, the distribution and magnitude of space charges in oxide can be found out accurately on the $V_{dp}$ in D-V curves. The density of interface states can be deduced with ease from the magnitude of D-peak at depletion state. Thus, it is also concluded that the D-V curves are more useful and easier than conventional C-V curves for analysis of the microscopic and dynamic behavior of carriers in oxide and Si- $SiO_2$interface.

  • PDF

Study on the Development and Application of Image Viewer System (Image Viewer System의 개발 및 적용에 관한 고찰)

  • Yang, Oh-Nam;Seo, In-Ki;Hong, Dong-Ki;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The number of patients receiving radiotherapy has increased every year and will keep increasing in the future. Therefore, the technique of radiotherapy is developing from day to day, as a result of it, the quantities of image and data used for radiotherapy are also considerably increasing. Therefore, there have been many difficulties in storing, keeping and managing them. Then, we developed and applied this system for improving complicated work process as well as solving these problems with the collaboration Medical Information Team. Materials and Methods: We exported its image at R & V (Record and Verify: Varis vision, Varian, USA) system and planning system after giving some code to be able to access from management system(RO) for department of radiation oncology to PACS. And, we programmed their information by using necessary information among many information included in DICOM head. Results: All images and data generated by our working environment (Simulation CT, L-gram image and internal body structure, DRR, does distribution )were realized at PACS and it became to be possible for clear image to be printed from any computer in department of radiation oncology. Conclusion: It was inevitable to use film during radiotherapy for patients in the past, however, due to the development of this system, film-less system became to be possible. Therefore, the darkroom space and its management cost in relation to the development process disappeared and it became to be unnecessary for spending tangible and intangible financial expense including human resources, time needed for finding film storing space and film and purchasing separate storing equipment for storing images. Finally, we think this system would be very helpful to handle ail complicated processes for radiotherapy and increasing efficiency of overall working conditions.

  • PDF

A Definition of Korean Heat Waves and Their Spatio-temporal Patterns (우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴)

  • Choi, Gwang-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.5 s.116
    • /
    • pp.527-544
    • /
    • 2006
  • This study provides a definition of heat waves, which indicate the conditions of strong sultriness in summer, appropriate to Korea and intends to clarify long term(1973-2006) averaged spatial and temporal patterns of annual frequency of heat waves with respect to their intensity. Based on examination of the Korean mortality rate changes due to increase of apparent temperature under hot and humid summer conditions, three consecutive days with at least $32.5^{\circ}C,\;35.5^{\circ}C,\;38.5^{\circ}C,\;and\;41.5^{\circ}C$ of daily maximum Heat Index are defined as the Hot Spell(HS), the Heat Wave(HW), the Strong Heat Wave(SHW), and the Extreme Heat Wave(EHW), respectively. The annual frequency of all categories of heat waves is relatively low in high-elevated regions or on islands adjacent to seas. In contrast, the maximum annual frequency of heat waves during the study period as well as annual average frequency are highest in interior, low-elevated regions along major rivers in South Korea, particularly during the Changma Break period(between late July and mid-August). There is no obvious increasing or decreasing trend in the annual total frequency of all categories of heat waves for the study period However, the maximum annual frequencies of HS days at each weather station were recorded mainly in the 1970s, while most of maximum frequency records of both the HW and the SHW at individual weather stations were observed in the 1990s. It is also revealed that when heat waves occur in South Korea high humidity as well as high temperature contributes to increasing the heat wave intensity by $4.3-9.5^{\circ}C$. These results provide a useful basis to help develop a heat wave warning system appropriate to Korea.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF