• Title/Summary/Keyword: 공간선량분포

Search Result 59, Processing Time 0.024 seconds

Evaluation of the Apron Effectiveness during Handling Radiopharmaceuticals in PET/CT Work Environment (PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가)

  • Cho, Yong-In;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.237-244
    • /
    • 2015
  • Health professionals in nuclear medicine were known that they get high radiation exposure. To reduce radiation exposure, using shielding materials is needed. In this study, we analyzed the shielding effect about apron during 18F-FDG treatment by using simulation based on Monte Carlo techniques and actual measurement. As a result, absorbed dose distribution of organ varies with handling position of the source. Dose reduction ratio by lead thickness of apron tended to decease, when handling position of the source come close to organ and away from radiation source for simulation. In the case of actual measurement with the dosimetry device, It showed that mean spatial dose distribution was different due to characteristics of dosimetry device. However, spatial dose rate was exponentially reduced according to distance with increasing lead content.

Spatial dose distribution and exposure dose during lumbar lateral test (요추 측면 검사 시 공간선량 분포와 피폭선량)

  • Kim, Chang-Gyu
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • During the lateral x-ray testing of lumbar, in order to obtain the optimal image for diagnosis and to minimize the exposure dose, a glass dosimeter and spatial dose measuring meter was used to measure and evaluate the exposure dose and spatial dose distribution of each organs. The exposure dose of the organs have increased as they were closer to the X-ray tube and when the radiation field was completely opened, the exposure dose was increased. In addition, scattered rays have increased as the distance got closer to the subject and with the distance of more than 200cm, 95% of scattered rays was reduced. Such results can anticipate the exposure dose of patients during the lumbar x-ray test in the future and it can be proposed as a data for determining the testing methods and expected to be widely used as an important basic data for reducing the medical exposure dose.

Dosimetry by Using EBT2 Film for Total Skin Electron Beam Therapy (TSET) (전신 피부 전자선 치료(TSET)에서 EBT2 필름을 사용한 선량측정)

  • Hwang, Ui-Jung;Rah, Jeong-Eun;Jeong, Ho-Jin;Ahn, Sung-Hwan;Kim, Dong-Wook;Lee, Sang-Yeob;Lim, Young-Gyung;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Park, Sung-Young;Pyo, Hong-Ryull;Chung, Weon-Kuu
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.60-69
    • /
    • 2010
  • For treatment of Total Skin Electron beam Therapy (TSET), measurement of dose at various conditions is need on the contrary to usual radiotherapy. When treating TSET with modified Stanford technique based on linear accelerator, the energy of treatment electron beam, the spatial dose distribution and the actual doses deposited on the surface of the patient were measured by using EBT2. The measured energy of the electron beam was agreed with the value that measured by ionization chamber, and the spatial dose distribution at the patient position and the doses at several point on the patient's skin could be easily measured by EBT2 film. The dose on the patient that was measured by EBT2 film showed good agreement with the data measured simultaneously by TLD. With the results of this study, it was proven that the EBT2 film can be one of the useful dosimeter for TSET.

Distribution and Management of Spatial Dose Rate in Neuro Angio Room (두개부 혈관조영실에서 공간산란선량의 분포와 관리)

  • Lee, Mi-Hwa;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Kim, Ki-Jeong;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.427-435
    • /
    • 2014
  • This study is performed in the intervention unit, during interventional procedures and in accordance with the direction and distance during the exposure indoor space is to measure the dose. I was classified at an angle of $45^{\circ}$ counterclockwise from the phantom. Seven(A, B, C, D, E, F, G) were classified as direction. Length was measured from the center of the phantom. Each direction 50cm, 100cm, 150cm, 200cm were classified. I was analyzed by measuring of frontal, lateral, Bi-plan fluoroscopic Spatial dose rate in all 28 points. Measured dose was the highest at 50cm and over 200cm, dose was rapidly decreasing as increased distance. Dose was different more than nine times depending on the distance and direction, Installation of shielding wall can reduce exposure about 84.52% to 93.54%.

Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

Calculation of Shielding Rate and Dose Distribution of Space of L-Block-Type Protective Equipment for Radioactive Fluorine using the Monte Carlo Method (몬테칼로 방법을 이용한 방사성 불소에 대한 L-블럭형 방호장비의 차폐율 및 공간의 선량분포 계산)

  • Han, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.813-819
    • /
    • 2021
  • In this study, the shielding rate of L-block-type shielding equipment used for radiation protection when radioactive fluorine is injected into the human body and the dose distribution of the space in the injection room were calculated using the Monte Carlo method. The shielding rate of the body and window parts of the L-block-type shielding equipment was 99.99%. The dose distribution calculated at a distance of 1 m was relatively high at 135°, 45°, 225°, 315°, and 180° of the XZ plane, and was calculated to be very low at 0°, 90°, and 270°. In the YZ plane, it was relatively high at 135°, 180°, and 225°, and was calculated very low at the remaining angles. The AZ and BZ planes also showed similar results to the YZ plane. In addition, it was confirmed that the shielding rate was the best in the range of 225° to 315° through the dose distribution in the horizontal direction of the source and the 45° direction above the source. These results can be used as basic data necessary for radiation protection of radiation workers.

The Measurement of Spatial Dose Rate by Gravity Ventilation after Technegas Scanning (Technegas 스캐닝 후 중력환기에 의한 공간선량율 측정)

  • Kim, Sung-Bin;Won, Do-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.667-674
    • /
    • 2019
  • Because examination with technegas produces images through simple diffusion accumulation, the examination room can become contaminated after scan. Therefore, radiation workers and patients awaiting examination will be affected by internal exposure from technegas inhalation. Before and after gravity ventilation, I am trying to find a way to reduce the exposure dose of waiting patients according to a comparative analysis of horizontal spatial dose rates over time. Spatial dose ratio were measured for 10 minutes from various distances and angles around ventilator's location before and after gravity ventilation. Then, mean values, standard deviation and reduction ratio were calculated. The highest reduction rate of gravity ventilation was 95.31% and the highest reduction ratio was 1 to 3 minutes. Therefore, the gravity ventilation could reduce the exposure dose of radiologic technologists, waiting patients, patient guardians and nurses. In conclusion, the reduction of the exposure dose during the technegas ventilation study through gravity ventilation will play a role in optimiging the protection and it is in accordance with the recommended reduction of the medical exposure by ICRP 103.

The Study and Measurement of Three Dimensional Spatial Dose Rate from Radioiodine Therapy (고용량 옥소 치료 시 3차원적 공간선량률 측정 및 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.251-257
    • /
    • 2013
  • Spatial dose rates of high dose $^{131}I$ therapy patients were Measured Three dimensional (X, Y, Z) distributions. I have constructed geometrical an aluminum support structure for spatial dose meters placed in 5 different heights, 8 different azimuthal angles, 6 different time interval and distance 100 cm from High dose$^{131}I$ therapy patients. when the height of vertical plane Spatial dose distribution is 100 cm, the Spatial dose rates is max and the error range is low. the vertical plane Spatial dose rates was found to be 71.85 ${\mu}Sv/h$ on the average at a distance of 100 cm, height 100 cm, from the patients 24 hours after $^{131}I$ oral administration. I divided 12 patients into two groups. I have analysed group A (drinking 5 L water) and group B (drinking 3 L water) in order to measure decrease spatial dose rates. I have found the spatial distributions of patient dose rates is $44.9{\pm}7.2$ ${\mu}Sv/h$ in group A and $100.3{\pm}8.1$ ${\mu}Sv/h$ in group B by 24 after $^{131}I$ oral administration. the reduction factor was found to be approximately 54 % through drinking 5 L water during 24 hours.

포항방사광가속기 저장링시운전시의 방사선측정

  • 이희석;김제한;홍석모;박응수;정진화
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.899-905
    • /
    • 1995
  • 포항방사광가속기(Pohang Llght Sousrc)의 시운전기간동안 저장링건물에서의 방사선발생량을 측정하였다. Ionization Chamber와 Moderated BF$_3$ Counter로 구성된 지역방사선감시기시스템(RMS)외에 Pocket Inonization chamber, 연속기록이 가능한 Surveymeter를 고정 또는 이동시키면서 사용하였다. 시운전기간동안 선형가속기로부터의 입사시기와 저장시기에서의 방사선방출분포 및 선량의 정도가 명확히 구별되었으며 RF Cavity나 Bump Magnet등의 오동작에 의한 방사선 발생경로를 추정해 볼 수 있었다 여기서는 저장링실험지역 등에서의 공간선량분포와 부분차폐에 따른 변화를 측정하였으며 측정결과로부터 차폐계산시 사용된 방법을 통해 역으로 각 지역의 빔손실정도를 추정하고 계산식의 타당성을 검토해 보았다.

  • PDF

Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields (Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.337-345
    • /
    • 1998
  • Purpose : To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated Materials and Method : The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of target-skin distance (TSD) and full collimator size (35*35 $cm^2$ on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cm * 105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. Results : The full width at half maximum(FWHM) of dose profile was 130 cm in large field of 105*105 $cm^2$ The width of $100\pm10\%$ of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose unifomity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80$\%$ depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. Conclusion : The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within$\pm10\%$ difference except the protruding area of skin which needs a shield and deeply curvatured region of skin which needs boosting dose.

  • PDF