• Title/Summary/Keyword: 골조 실험

Search Result 310, Processing Time 0.02 seconds

Compressive Strength Development Properties of Concrete using Sodium based Accelerating Admixtures (나트륨계 기반 조강형 혼화제를 사용한 콘크리트의 압축강도발현 특성)

  • Song, Yeong-Chan;Lee, Tae-Gyu;Kim, Yong-Ro;Seo, Chi-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.259-266
    • /
    • 2018
  • In recent years, the early strength of concrete is important in order to shorten the time of form removal at the construction site. The purpose of this study is to analyze the moment of form removal as investigating the amount of cement contents and the physical properties and strength of the concrete according to types of admixture in the curing temperature of $10^{\circ}C$ for concrete of 21 to 27 MPa. As a result, it was found that compressive strength of concrete could not be secured 5 MPa by 36 hours even if the amount of cement contents were increased to $360kg/m^3$ with plain admixture. Also, it was confirmed that the strength improvement rate was excellent when using the accelerating agent with polycarboxylic acid type, and the moment of compressive strength of 5 MPa was estimated at 30 hours.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.

Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters (교정용 마이크로 임플란트의 디자인이 토오크와 파절강도에 미치는 영향)

  • Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.171-181
    • /
    • 2007
  • Objective: The present study was aimed at an analytical formulation of the micro-implant related torque as a function of implant size, i.e. the diameter and length, screw size, and the bony resistance at the implant to bone interface. Methods: The resistance at the implant to cancellous bone interface $(S_{can})$ was assumed to be in the range of 1.0-2.5 MPa. Micro-implant model of Absoanchor (Dentos Inc. Daegu, Korea) was used in the course of the analysis. Results: The results showed that the torque was a strong function of diameter, length, and the screw height. As the diameter increased and as the screw size decreased, the torque index decreased. However the strength index was a different function of the implant and bone factors. The whole Absoanchor implant models were within the safe region when the resistance at the implant/cancellous bone $(=S_{can})$ was 1.0 or less. Conclusion: For bone with $S_{can}$ of 1.5 MPa, the cervical diameter should be greater than 1.5 mm if micro-implant models of 12 mm long are to be placed. For $S_{can}$ of 2.0 MPa, micro-implant models of larger cervical diameter than 1.5 mm were found to be safe only if the endosseous length was less than 8 mm.

A Comparison Study on Animal Models for Osteoarthritis in Temporomandibular Joint (측두하악관절에서의 골관절염 유도 동물모델 비교연구)

  • Yu, Sun-Nyoung;Yi, Young-Chul;Park, Hae-Ryoun;Ryu, Mi-Heon;Jeon, Hye-Mi;Kim, Kwang-Youn;Kim, Sang-Hun;Ok, Soo-Min;Ko, Myung-Yun;Ahn, Yong-Woo;Ahn, Soon-Cheol;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.4
    • /
    • pp.261-271
    • /
    • 2011
  • Osteoarthritis in patients with temporomandibular disorders(TMDs) induces pain, limitation of mouth opening, occlusal problems, and most commonly affects their life quality. Control method and progressive process of osteoarthritis are being extensively researched. The researchers focus on histologic changes, synovial changes, muscular and ligamental changes and observed reaction to pain. Therefore most of them developed the animal model for osteoarthritis in TMD patients. In this study, we applied several methods which induces osteoarthritis of temporomandibular joint(TMJ) in rats or mice. For locally induce osteoarthritis in TMJ, Monosodium iodoacetate(MIA) or interleukin-$1{\alpha}$(IL-$1{\alpha}$) were injected into TMJ joint space for 5 or 3 weeks. Other groups are chosen for osteoarthritis under systemic control including hormonal changes and aging. To observe cellular change, increased collagen, degenerative bony destruction and distribution of proteoglycans (PGs), safranin-O staining and Masson's trichrome staining were used.

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF

Considerations in implant crestal module to preserve peri-implant tissue (임플란트 주위 조직 보존을 위한 임플란트 경부의 디자인에 관한 고찰)

  • Kim, Hong-Jun;Kim, Jee-Hwan;Kim, Sung-Tae;Lee, Jae-Hoon;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • Purpose: The peri-implant soft tissue is remodeled by the initial marginal bone resorption affecting the prognosis and esthetic result of treatment. Thus various designs on implant neck design are studied to preserve peri-implant bone. The purpose of this study is to review on the causes of initial marginal bone resorption, the configuration of peri-implant soft tissue, and the implant crestal module favorable in preserving peri-implant tissue. Materials and methods: The studies on the causes of initial marginal bone resorption and the implant crestal modules are researched and reviewed using Pubmed database. The implant crestal modules including one piece and two-piece implant, internal and external hex abutment, taper and butt joint connection, scalloped design abutment, and platform switching concept are reviewed. Results: A number of clinical and experimental studies preferred one piece implant to two-piece in preserving initial peri-implant tissue. For two piece implants, internal hex abutment and taper joint connection appear more favorable than external hex abutment and butt joint connection relatively. Controversial issues still exist on scalloped design requiring more studies on it. Although the rationale is not certain, the concept of platform switching seems favorable in preserving initial peri-implant tissue based on clinical and experimental studies. Conclusion: Each implant crestal module contains its own advantages and disadvantages with various controversial issues. In the aspect of preservation of initial peri-implant tissue, however, one-piece implant seems beneficial. In cases when two-piece implant is more appropriate due to prosthodontic concerns or any other problems, the application of platform switching concept, internal connection abutment, and taper joint connection may be favorable for the preservation of peri-implant tissues.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

EFFECTS OF $INTERFERON-\gamma$ ON COLLAGEN AND FIBRONECTIN SYNTHESIS IN PRIMARY CULTURED PERIODONTAL LIGAMENT CELLS ($Interferon-\gamma$가 치주인대 세포의 Collagen 및 Fibronectin의 합성과 Alkaline Phosphatase 활성에 미치는 영향)

  • Kim, Gwang-Seok;Sung, Jae-Hyun;Choi, Je-Yong;Ryou, Hyun-Mo
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.229-248
    • /
    • 1993
  • [ $Interferon-\gamma$ ] has been suggested as a cytokine of connective tissue stabilizer. In addition, it has also been demonstrated that this cytokine inhibited bone remodeling activities of the bone derived cells. In order to illuminate the effects of this cytokine in orthodontic force induced bone remodeling, it was administered to primary cultured periodontal ligament cells which have been known to have some osteoblast like characteristics. $Interferon-\gamma$ slightly decreased $[^3H]thymidine$ incorporation rate without a significant change in the total cellular DNA content up to 1000 U/ml, which meant these doses were not cytotoxic to the cell. Total protein synthesis was not influenced by various concentration of interferon-y whether it was determined by the $[^3H]proline$ incorporation rate or by the Lowry smethod. The effect of $interferon-\gamma$ on the individual protein was, however, differential, ie, it increased $[^3H]proline$ incorporation into the noncollagenous protein marginally, while it decreased $[^3H]proline$ incorporation into the collagen, so that it caused dose-dependent suppression of the relative collagen synthesis. On the contrary, the fibronectin synthesis determined by the ELISA was increased by 1000 U/ml of $interferon-\gamma$. The differential effects of the interferon-y on the collagen and fibronectin synthesis exhibited not only their protein level but also the steady state mRNA level. $Interferon-\gamma$ decreased steady state level of ${\alpha}1(I)$ procollagen mRNA significantly, while showing no significant changes in the fibronectin mRNA level. In addition to this, it was also found that indomethacin did not affect on the $interferon-\gamma$ induced collagen decrease in this cell, which meant prostaglandins were not involed in the process of $interferon-\gamma$ induced collagen decrease. So it can be concluded that the incubation of periodontal ligament cells with 1000 U/ml of $interferon-\gamma$ for 24 hr showed differential effects on the type I collagen and fibronectin gene expression. The decrease in relative collagen synthesis in the protein level was related with decrease in the steady state level of mRNA, while the increase in the fibronectin synthesis in the protein level was not correlated with the mRNA level.

  • PDF