A Study on Development of Numerical Analysis Method Behavior for Properties of Steel Structure Member and Frame (강구조 부재와 골조의 거동 성상에 대한 해석수법의 개발에 관한 연구)

  • 박정민;김화중;이상재
    • Computational Structural Engineering
    • /
    • v.9 no.1
    • /
    • pp.115-123
    • /
    • 1996
  • This paper was developed to computer program, which is about to analyize nonlinear behavior of structural member and frame including to geometric and material nonlineality, and formulated to the relationship of stress-strain of steel. In order to examplity the efficiency of this program, the numerical analysis was done for H section steel beam and square steel tube column subjected to monotonic load, and braced steel frame subjected to repeated horizontal forces. The obtained results by this program were in accordance with existing experimental and analytical results respectively.

  • PDF

Seismic Performance of Gravity-Load Designed Post-Tensioned Flat Plate Frames (중력하중으로 설계된 포스트텐션 플랫플레이트 골조의 내진성능)

  • Han, Sang-Whan;Park, Young-Mi;Rew, Youn-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.31-38
    • /
    • 2010
  • The purpose of this study is to evaluate the seismic performance of gravity-designed post tensioned (PT) flat plate frames with and without slab bottom reinforcement passing through the column. In low and moderate seismic regions, buildings are often designed considering only gravity loads. This study focuses on the seismic performance of gravity load designed PT flat plate frames. For this purpose, 3-, 6- and 9-story PT flat plate frames are designed considering only gravity loads. For reinforced concrete flat plate frames, continuous slab bottom reinforcement (integrity reinforcement) passing through the column should be placed to prevent progressive collapse; however, for the PT flat plate frames, the slab bottom reinforcement is often omitted since the requirement for the slab bottom reinforcement for PT flat plates is not clearly specified in ACI 318-08. This study evaluates the seismic performance of the model frames, which was evaluated by conducting nonlinear time history analyses. For conducting nonlinear time history analyses, six sets of ground motions are used as input ground motions, which represent two different hazard levels (return periods of 475 and 2475 years) and three different locations (Boston, Seattle, and L.A.). This study shows that gravity designed PT flat plate frames have some seismic resistance. In addition, the seismic performance of PT flat plate frames is significantly improved by the placement of slab bottom reinforcement passing through the column.

An Analytical Study on the Behavior of Steel Frames with Semi-Rigidity of Beam-to-Column Connections (반강접 접합부를 갖는 강골조의 거동에 대한 해석적 연구)

  • Kim, Jong Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.551-559
    • /
    • 2003
  • In steel frames, the analysis and design techniques are based on either idealized fixed or pinned connections. In this case, it has the advantage that the structural analysis and the design procedure were simplified, but there could be given different results of analysis between the real steel frame connections and the idealized fixed and pinned connection. This is because the real connections would be analyzed by semi-rigid, and have some transfer of moment and rotational constraint about the loads. In this study, structural analysis program with considered connections that have joint rigidity of fixed, pinned and semi-rigid, was developed. Then, the effects of joint rigidity on strength and displacement. in steel frames subjected to lateral forces and axial forces, were investigate, and the results were compared with those of the Midas Gen. w program.

A Study on the Inelastic Analysis of Planar Frames Subjected to Cyclic Loads Using Direct Method (직접해석법에 의한 반복하중을 받는 평면골조의 비탄성해석에 관한 연구)

  • 정일영;이상호;윤태호
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.65-74
    • /
    • 1995
  • Direct method developed for the inelastic analysis of planar frames subjected to monotonic loads is extended to cyclic loads. Two frame elements for Direct Method(inelastic truss and inelastic beam) are developed. The accuracy and reliability of the preposed method is verified by comparing the analysis results of example with step-by-step analysis. Direct Method is superior to Step-by-step analysis in view of reliability of solution and analysis cost.

  • PDF

Inelastic Dynamic Demands of a RC Special Moment Frame Building (철근 콘크리트 특수 모멘트 골조 건물의 비탄성 동적 요구값)

  • Kim, Tae-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.11-19
    • /
    • 2005
  • Seismic design of a building is usually performed by using the linear static procedure. However, the actual behavior of the building subjected to earthquake is inelastic and dynamic in nature. Therefore, inelastic dynamic analysis is required to evaluate the safety of the structure designed by the current design codes. For the validation, a RC special moment resisting frame building was chosen and designed by IBC 2003 representing new codes. Maximum plastic rotation and dissipated energy of some selected members were calculated for examining if the inelastic behavior of the building follows the intention of the code, and drift demand were calculated as well for checking if the building well satisfies the design drift limit. In addition, the effect of including internal moment resisting frames (non lateral resisting system) on analyses results was investigated. As a result of this study, the building designed by IBC 2003 showed the inelastic behavior intended in the code and satisfied the design drift limit. Furthermore, the internal moment resisting frames should be included in the analytical model as they affect the results of seismic analyses significantly.

3-D Configuration Effects of Prestressing Cable Bracing Used for Retrofitting a RC Frame Subjected to Seismic Damage (RC 골조의 내진 보강을 위한 예압 가새의 3-D 배치)

  • Lee, Jin-Ho;Oh, Sang-Gyun;Hisham, El-Ganzori
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.183-191
    • /
    • 2003
  • A four-story reinforced concrete moment resisting frame damaged from an ultimate limit state earthquake is upgraded with prestressing cable bracing. The purpose of this study is to investigate the bracing configuration effects on the 3-D building response using thee different locations of the bracing systems for the retrofitted building. Since the previous work done by the author proved that static incremental loads to collapse analysis as a substitute to dynamic non-linear time history analysis was a valid alternative tool. Thus, static load to collapse analysis is solely applied to evaluate the seismic performance parameters of both the original and upgraded buildings in this study. In results, the exterior bracing system is effective in restraining torsional behavior of the structure under seismic loads, and no sudden failure occurs in this system that enhances the ductility of the building due to the gradual change of building stiffness as the lateral load increases.

Analysis of Behaviors of SPS Underground Composite Frames Considering the Rigidity of RC Wale-Steel Beam Joint (RC 띠장-철골 보 접합부의 고정도에 따른 SPS 지하복합골조 거동 해석)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.243-250
    • /
    • 2004
  • In SPS system, steel beams are used as not only temporary struts supporting the wale but main flexural members of building. Previous experimental works show that RC wale-steel beam joints have some flexural rigidity. In this paper, nonlinear analysis is performed using DRAIN-2DX program to investigate the behaviors of the underground composite frames constructed with SPS system when the rigidity of RC wale-steel beam joints change. Analysis variables are the procedure of construction, magnitude of lateral forces, and flexural rigidity of the RC wale-steel beam joint with stud connector. Analysis results show the effects of joint rigidity for the yielding process of frame and the moment and deflection at the mid-span of beam.

Nonlinar Analysis of Reinforced Concrete Frames Considering The Strain-Softening of Concrete (변형연화현상을 고려한 철근콘크리트 골조의 비선형 해석)

  • 김진근;이태규
    • Magazine of the Korea Concrete Institute
    • /
    • v.1 no.1
    • /
    • pp.105-114
    • /
    • 1989
  • 휨을 받는 철근콘크리트 부재 단면의 연화현상은 구조물의 파괴하중 해석시 중요한 인자로 작용한다. 일반적인 탄-소성 이론에 근거한 소성한계해석법을 사용할 경우 철골 구조물에는 적합하지만 철근콘크리트 구조물에는 최대하중 이후의 연화현상으로 인하여 이 이론은 부적합하게 된다. 따라서 본 논문의 주목적은 변위제어방법을 사용하여 철근콘크리트 구조물이 파괴될 때까지의 완전한 거동을 이끌어 내는 것이다. 프로그램을 사용한 계산결과를 보다 빠르고 경제적으로 이끌어 내기 위하여 단면의 성질인 모멘트-곡률, 축력-축\ulcorner향 변형률, 그리고 전단력 변형률 곡선 등을 여러개의 직선적으로 단순화한 모델식을 사용하여 해석한다. 또한 연화현상을 고려한 유한요소의 해석결과는 사용된 요소의 크기에 따라 결과가 매우 다르게 나타나기 때문에 이를 방지하기 위하여 파괴에너지 개념을 도입하여 모멘트-곡률 곡선을 보정하여 구조계산에 적용시킨다. 이와 같이 단면을 층으로 나누어 해석하지 않고 직접 단면의 성질을 나타내는 곡선들을 적용한 본 프로그램으로 보와 골조를 해석한 결과는 실제적인 실험결과와 비교하였을 경우 거의 일치하게 나타난다.

Seismic Analysis of Mid Rise Steel Moment Resisting Frames with Relative Stiffness of Connections and Beams (접합부와 보의 상대강성을 고려한 중층 철골 모멘트 골조의 내진해석)

  • Ha, Sung-Hwan;Kang, Cheol-Kyu;Han, Hong-Soo;Han, Kweon-Gyu;Choi, Byong-Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.595-606
    • /
    • 2011
  • This study was conducted to investigate the seismic behavior of steel member resisting frames considering the relative stiffness of the connection and beams. Six-story steel moment frames were designed to study the seismic behavior. The connections were classified into Double Web-Angle connections (DWAs), Top- and Seat-angles with double Web-angles (TWSs), FEMA-Test Summary No. 28, Specimen ID: UCSD-6 (SAC), and Fully Restrained (FR). The rotational stiffness of the semi-rigid connections was estimated using the Three-Parameter Power Model adopted by Chen and Kishi. The relative stiffness, which is the ratio of the rotational stiffness of the connections to the stiffness of the beams, was used. Push-over, repeated loading, and time history analysis were performed for all the frames. The seismic behavior of each frame was analyzed with the story drift, plastic hinge rotation, and hysteretic energy distribution.