• Title/Summary/Keyword: 골절 정복

Search Result 222, Processing Time 0.022 seconds

Malignant Tumor Mistaken for Infection or Stress Fracture - 4 cases report - (감염이나 피로 골절로 오인된 악성 종양 - 4례 보고 -)

  • Han, Chung-Soo;Lee, Young-Ho;Ha, Jeong-Han
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.93-100
    • /
    • 2003
  • Clinical outcome of malignant tumor heavily depends on early diagnosis and proper management of the patient. But it's very difficult to diagnose malignant tumor in early stage because of it's vague symptoms and inadequate evidences of malignancy in radiologic studies and biopsy. Malignant tumor mistaken for infection or fracture initially will undergo inadequate treatment and that will influence on it's prognosis. So it's very important to rule out the possibility of malignancy by repeated evaluation if it's diagnosis is not definite. We report 1 case of osteosarcoma initially mistaken for stress fracture and 3 cases of osteosarcoma, malignant lymphoma and Ewing's sarcoma initially mistaken for tuberculosis and review the literature.

  • PDF

Intestinal Strangulation Associated with Pubic Fracture in a Dog (개에서 치골골절과 연관된 장폐색)

  • Lee, Jae-Il;Kim, Young-Suk;Jeong, Seong-Mok;Kim, Myung-Jin;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.458-460
    • /
    • 2006
  • A 2-year-old female, 3.8kg weight, mixed-breed dog was presented for a 10-day history of vomiting and anorexia. The dog was diagnosed with pelvic fracture by vehicular accident at a local animal hospital before 2 months, but fracture did not reconstructed. After 2 months, the dog suffered from intermittent vomiting and anorexia. On barium contrast, we diagnosed the dog as intestinal obstruction. Consequently, we were found obstruction by strangulation and adhesion of intestine at the fracture site through the operation. At present after 18 months of surgery, general physical condition of the dog is good.

Biodegradable Meniscus Screw Fixation of Thin Flap Osteochondral Fracture - Two Case Report - (흡수성 반월상 연골나사를 사용한 얇은 골연골 골절의 치료 - 증례 보고 -)

  • Chon, Je-Gyun;Sun, Doo-Hoon;Song, In-Soo;Kim, Young-Woo;Jung, Jae-Yong;Lee, Bong-Ju
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.131-134
    • /
    • 2010
  • Inappropriate treatment of osteochondral fracture can cause osteoarthritis, pain, functional disorder. With large osteochondral fracture, reduction and fixation of the fragment using metal implant. However, when the bone fragment had less than 2mm, the fragment extracted because of difficulty of fragment fixation. Authors treated patients with fracture fragment thickness less than 2mm of osteochondral dissecans in medial femoral condyle and patella fracture using biodegradable meniscus screw, and then we obtained good result.

  • PDF

Traumatic Posterior Dislocation of the Shoulder with Ipsilateral Humeral Surgical Neck Fracture in a Child - A Case Report - (소아에서 동측 상완골 외과적 경부 골절을 동반한 외상성 견관절 후방 탈구 - 증례 보고 -)

  • Kang, Suk;Chung, Phil-Hyun;Kim, Jong-Pil;Kim, Young-Sung;Lee, Ho-Min;Kim, Jong-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.80-83
    • /
    • 2011
  • Purpose: Traumatic posterior dislocation of the shoulder in a child is extremely rare, and posterior dislocation of the shoulder concomitant with ipsilateral humeral surgical neck fracture has not been reported in a child previously in Korea. Materials and Methods: The authors treated a 10-year-old with posterior dislocation of left shoulder and an ipsilateral humeral surgical neck fracture, that occurred during Taekwondo practice, by open reduction of the shoulder and pin fixation under general anesthesia. Results: A normal range of motion with complete union and good remodeling was achieved without redislocation or avascular necrosis of humeral head at 1 year after surgery. Conclusion: The authors report a successfully treated case of traumatic posterior dislocation of the shoulder with an ipsilateral humeral surgical neck fracture in child.

Diagnosis and Management of Suspected Deltoid Injury (삼각인대 손상 의심 시 진단과 치료방법)

  • Yang, Sung Hun;Lee, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.1
    • /
    • pp.16-21
    • /
    • 2022
  • When an ankle lateral malleolar fracture is accompanied by a deltoid ligament rupture without a medial malleolar fracture, such an injury is called a bimalleolar equivalent fracture. This means that even if there is no bony injury on the medial side, there may be functional instability of the ankle joint due to damage to the deltoid ligament. Manual or gravity external rotational stress radiography is used to differentiate an ankle bimalleolar equivalent fracture from an isolated lateral malleolar fracture. If the medial joint gap is widened on the stress radiography, the deltoid ligament injury can be diagnosed, and surgical treatment for fibula fractures is recommended. After open reduction of the fibula fracture (with syndesmotic fixation if needed), a decision on the repair of the deltoid ligament is taken depending on the surgeons' preference and intraoperative findings. The deltoid ligament repair is performed by inserting a suture anchor (or anchors) in the medial malleolus and fixing the deep and superficial deltoid ligaments to the medial malleolus. The only randomized study to evaluate the utility of deltoid ligament sutures in ankle fractures did not support the deltoid ligament suture, but the study itself had many limitations. An appropriately powered, randomized, controlled trial of the deltoid ligament repair with both patient-reported outcome and radiographic outcome evaluation is needed in the future.

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Clinical Observation and Treatment of Fracture-Dislocation of Talus (거골 골절 및 탈구의 임상적 고찰)

  • Lee, Dong-Chul;Kim, Se-Dong;Jung, Hae-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.302-311
    • /
    • 1992
  • Talus is a important structure of the ankle joint and its function is critical for ambulation and weight bearing. The talus fracture is rare, but the complications of fracture and dislocation are serious and resulting in avascular necrosis, osteoarthritis. So its treatment is carefully considered at initial status. Authors reviewed 11 cases of fracture and dislocation of the talus treated at Yeungnam university hospital from 1984 to 1991. The longest follow up was 8 years and shortest, 1 year. The results were as follows. 1. There were all males, the average age was 30 years old. 2. The most common cause was fall down(8 cases), and next traffic accident(2cases), sports injury(1 case). 3. According to Marti-Weber classification, 1 cases was type I, 1 in type II, 4 in type III and 5 in type IV. 4. The method of treatment were open reduction and internal fixation in 6 cases, the others were closed reduction in 5 cases. 5. Final results(by Hawkins grading system) were as follows, 3 cases were excellent, 4 cases were good, 1 case was fair and 3 cases were poor. 6. Complications were AVN in 2 cases, degenerative arthritis in 8 cases, malunion in 1 case. 7. The range of motion of the ankle joint was relatively preserved(74%), but in the subtalar joint it was decreased(43%).

  • PDF

Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb (오픈소스 기반 수술항법장치의 하지 골절수술 응용검토)

  • Joung, Sanghyun;Park, Jaeyeong;Park, Chul-Woo;Oh, Chang-Wug;Park, Il Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.497-503
    • /
    • 2014
  • Minimally invasive intramedullary nail insertion or plate osteosynthesis has shown good results for the treatment of long bone fractures. However, directly seeing the fracture site is impossible; surgeons can only confirm bone fragments through a fluoroscopic imaging system. The narrow field of view of the equipment causes malalignment of the fracture reduction, and radiation exposure to medical staff is inevitable. This paper suggests two methods to solve these problems: surgical navigation using 3D models reconstructed from computed tomography (CT) images to show the real positions of bone fragments and estimating the rotational angle of proximal bone fragments from 2D fluoroscopic images. The suggested methods were implemented using open-source code or software and evaluated using a model bone. The registration error was about 2 mm with surgical navigation, and the rotation estimation software could discern differences of $2.5^{\circ}$ within a range of $15^{\circ}$ through a comparison with the image of a normal bone.

Alternative Fixation Technique for Bony Bankart Lesion with Using Suture Anchor (봉합나사와 골터널을 이용한 골성 반카르트 병변의 고정)

  • Kim, Byung-Kook;Lee, Ho-Jae;Kim, Go-Tak;Dan, Jinmyoung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.574-578
    • /
    • 2019
  • For the treatment of a bony Bankart lesion accompanied by an acute traumatic shoulder dislocation, anatomical reduction and stable fixation of the bone fragment and glenohumeral ligament are essential to avoid chronic instability or degenerative changes. If the Bankart lesion has large bony pieces or comminuted fragments, it can be difficult to perform precise and secure fixation of the big intraarticular fragment to the fracture site because of the limited visualization of the arthroscopic procedure. In addition, in the case of the open procedure, it requires an extensive surgical dissection to access the fractured fragment, which may cause surgical approach-related morbidity, such as neurovascular complications, delayed subscapularis healing, and increased risk of stiffness. This paper describes an alternative open suture anchor technique for a large bony Bankart lesion, which was secured anatomically with squared knots after a shuttle relay through bony tunnels and adjacent soft tissue and labrum. This technique can achieve anatomical and firm fixation under direct vision, and reduce the number of surgery related morbidities.

Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures (Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법)

  • Song, Joo-Hyoun;Lee, Joo-Yup;Yang, Sung-Cheol;Lee, Han-Yong;Kim, Jong-Ik
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.199-203
    • /
    • 2007
  • Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.