• Title/Summary/Keyword: 골절 정복

Search Result 222, Processing Time 0.03 seconds

Subservient Bone Reduction with Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate) in Hand Fractures: Two Cases of Report (수부 골절 시 Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate)을 이용한 보조적 골 정복 2례)

  • Lee, Won;Lee, Sung-Hwan;Oh, Sang-A;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.102-104
    • /
    • 2011
  • Purpose: The standard treatments of hand fractures today are fixations by K -wires, metal plates, wires and lag screws. But it is very difficult to reconstruct fractures by placing implants into small bony fragments especially in the comminuted fractures and intra-articular fractures. This paper describes a simple method of reconstruction with Histoacryl$^{(R)}$ for comminuted and intra-articular fractures in hands. Methods: 2 cases with comminuted and intra-articular fractures by crushing injury were reconstructed with Histoacryl$^{(R)}$. We performed applying Histoacryl$^{(R)}$ with swab on the bone cortex carefully to avoid Histoacryl$^{(R)}$ infiltrating into the medulla. We could rearrange and fixate bony fragments using only Histoacryl$^{(R)}$, in addition, metal plates, K-wires, wires, and lag screws could be used for secondary fixation if needed. Results: Post-operative X-ray finding of 2 patients assured that the bony fragments of the hand fractures maintained their original positions. Significant displacement and deviation, infection, nonunion, and malunion during the follow-up period were not observed. Conclusion: This study showed the possibility of using Histoacryl$^{(R)}$ in addition as a simple method of fixation in the comminuted and intra-articular hand fractures.

Modified Essex-Lopresti Reduction for the Displaced Intra-articular Calcaneal Fractures (전위된 관절 내 종골 골절에 대한 Essex-Lopresti 변형 정복술)

  • Kwak, Kyoung-Duck;Cho, Hyoun-Oh;Lim, Dae-Hwan;Ahn, Sang-Min;Jang, Jae-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.109-114
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and indications of the modified Essex-Lopresti reduction in calcaneal fractures. Materials and Methods: We reviewed retrospectively 41 cases of displaced intraarticular calcaneal fractures. The fracture was reduced with Essex-Lopresti technique with modification in compression of the lateral wall with the specially designed compression device instead of the operator's hands. We evaluated the results of treatment by AOFAS scale and the radiographic parameters including the Bohler's angle, calcaneal width, calcaneofibular distance and the congruency of the posterior facet. Results: Boler's angle was restored from 11 to 29.6 degrees on average, heel width was reduced to 112% of contralateral value, the calcaneofibular gap was restored up to 87.9% of contralateral side, and the articular surface of the posterior facet was restored less than 2 mm of step off and less than 2 mm of gap. AOFAS scale averaged 87 points. The quality of reduction was best in Sander's type II fractures. Small sized fragments in type III fractures could not be reduced. The results were better when the reductions were performed within 24 hours of injury. Conclusion: The modified Essex-Lopresti reduction was less invasive, easy to perform, and the results of treatment were similar to those of open reduction; it seemed to be a reasonable alternative for the selected intraarticular calcaneal fractures.

  • PDF

Minimally Invasive Reduction and Pin Fixation Treatment for Displaced Intraarticular Calcaneal Fracture (최소 침습적 정복술 및 금속강선 고정술을 이용한 전위된 관절내 종골 골절의 치료)

  • Lee, Jin-Young;Park, In-Heon;Kim, Gab-Lae;Kim, Tae-Hwa;Oh, Bum-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.66-72
    • /
    • 2010
  • Purpose: To evaluate the clinical efficacy of the minimally invasive posterior approach for the surgical treatment of intraarticular fracture of calcaneus. Materials and Methods: From March 2006 to October 2008, we studied retrospectively 45 patients, 56 cases who were treated with minimally invasive reduction and pin fixation treatment for displaced intraarticular calcaneal fracture and were followed up for more than 1 year. The clinical results were evaluated with Creighton-Nebraska score and AOFAS score, circle draw test after 1 year. We checked simple AP, lateral, axial and Broden's view preoperatively and 1 year after surgery, and compared Bohler angle and Gissane angle. Results: By Creighton-Nebraska score, Sanders type 1 was 81, type 2 was 75, type 3 was 69, type 4 was 61. By AOFAS score, Sanders type 1 was 88, type 2 was 82, type 3 was 78, type 4 was 63. And by circle draw test, type 1 was 8.8 cm, type 2 was 8.5 cm, type 3 was 8 cm, type 4 was 6.6 cm. Preoperative Bohler angle and Gissane angle were $7.2^{\circ}$, $98^{\circ}$, and it increased to $21.2^{\circ}$, $116^{\circ}$ after postoperative 1 year. Conclusion: Minimally invasive reduction and pin fixation treatment for displaced intraarticular calcaneal fracture was considered to be an effective treatment modality.

Subacute Osteomyelitis on Phalangeal Bone Resulting from Multiple Kirschner Pin Fixation: Case Report (원위지 골절에 K-강선을 이용한 비관혈적 정복술 후 생긴 아급성 골수염 1례)

  • Kim, Jae Woo;Choi, Hwan Jun;Kim, Mi Sun;Kim, Jun Hyuk
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.409-412
    • /
    • 2007
  • Purpose: Percutaneous Kirschner wire fixation is common method for hand fracture. It is simple but has risk of ascending infection through the pin and bony injury by multiple drilling. Ascending infection through pin tract is mostly superficial and can be treated with antibiotics and aseptic dressing. This is a case review of subacute osteomyelitis on phalangeal bones after Kirschner wire fixation with literature review. Methods: A 40-years-old man with distal phalangeal fracture on right second finger is presented. He went to a local clinic and had percutaneous Kirschner wire fixation under local anesthesia. He was transferred to our hospital for ulcerative wound on DIP joint at 4 weeks after operation. Radiography showed osteolytic change around medulla of middle and distal phalanges, leading to diagnosis of a subacute osteomyelitis. We treated it with amputation at the level of shaft of middle phalanx. Results: The postoperative course was uneventful. We thought several possible reasons for osteomyelitis in our case. First, it could resulted from ascending infection through the wire. Second, it could be resulted from a bony burn by repeated drilling. And bony necrosis could be a consequence of arterial insufficiency caused by 2 pin insertion. Conclusion: We suggest that a precise pinning based on accurate anatomical understanding is required for a percutaneous Kirschner wire fixation. The frequency of drilling should be minimized. Careful observation and patient education for pin site care are essential.

The Useful Method on Temporary Fixation with Screw-wire Technique (안면골절의 정복 및 고정을 위한 나사-강선의 사용)

  • Kim, Myung Hoon;Kwon, Yong Seok;Heo, Jung;Lee, Keun Cheol;Kim, Seok Kwun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.181-186
    • /
    • 2008
  • Purpose: Until now, many kinds of treatment modalities for facial bone fractures have been proposed. Among them, the semi-rigid fixation using miniplates has become the most popular procedure due to its simplicity and good clinical results. However, achieving anatomic reduction of bone fragments with miniplates may be difficult because of inadequate instrumentation for fracture fragment stabilization. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of fractured segment. Methods: We used this method for reduction in 50 cases of facial bone fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning bony segment. Postoperative radiologic and clinical follow-ups were performed.Results: Radiologic follow-up showed correct reduction and fixation in all cases. Nonnunion and malunion were not shown. Clinical follow-up showed an satisfactory results. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the bony segment to their preinjury position is easy to perform and it enables us to make more accurate reduction, ensure wider visual field.

Closed Reduction of Zygomatic Arch Fracture with Intraoperative Mobile Computed Tomography Scan (관골궁 골절의 정복 시 술중 이동식 CT의 유용성)

  • Kim, Myung-Good;Noh, Yong-Joon;Lee, Hoon-Young;Kim, Min-Ho;Lee, Sin-Chul
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.91-94
    • /
    • 2010
  • Purpose: The purpose of this study is to describe the usefulness of intraoperative mobile CT scans in the reduction of zygomatic arch fracture. Method: Two patients with zygomatic arch fractures were selected who were indications of closed reduction by Gilles' approach. After the reduction was done in the operating room with zygomatic arch elevator, intraoperative CT scan was done to check the extent of reduction. Additional reduction was performed according to the obtained images from the intraoperative mobile CT scan. Examination of the preoperative CT, intraoperative CT after the reduction, and postoperative plain X-ray films were done for documentation and analysis. Results: Reduction was carried out successfully to the patients without any complications. Both patients were satisfied with the postoperative cosmetic and functional outcome. Revisional surgery was not necessary during the 6 months follow up. Conclusion: The advantage of this method is that it is easier to obtain three dimensional relationships of the fracture site. Furthermore, the operator is less exposed to radiation hazards compared to other methods that obtain intraoperative images such as the C-arm. In conclusion, intraoperative mobile CT scan can be a useful surgical aid in the reduction of zygomatic arch fractures.

Open Reduction and Internal Fixation of Displaced Intra-Articular Fractures of the Glenoid (전위된 견갑골 관절내 골절의 관혈적 정복 및 내고정술)

  • Kim Seung Key;Park Jong Beom;Choi Woo-Sung;Kwon Young-Jeong;Chang Han
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.230-235
    • /
    • 1998
  • Fractures of the scapula are relatively uncommon injuries and treatment in the vast majority of cases remains nonsurgical and the results have been quite satisfactory. But the scapular fracture itself may be neglected because of its high incidence of many kinds of associated injuries so its delayed treatment sometimes gives bad and unpredictable results. Although open reduction and internal fixation has been accepted as the treatment of choice for displaced intra-articular fractures in many anatomical regions, there has been no definite treatment principles of surgical indications and approaches in the glenohumeral joint. At our institution, II displaced intra-articular fractures of the glenohumeral joint were treated with open reduction and internal fixation from March 1993 to February 1997. This paper reports the results of treating 11 displaced intra­articular fractures of the glenoid by open reduction and internal fixation. There were 10 men and one woman and the fractures were classified according to Ideberg : Type Ⅰa(4), Type Ⅱ(3), Type Ⅲ(1), Type IV(1), Type Va(1), and Type Vc(1).

  • PDF

Airway Improvement After Reduction of Nasal Bone Fracture (비골 골절 정복 후 비강 내 기도 폐색의 개선)

  • Kim, Sang-Bum;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.49-54
    • /
    • 2005
  • Evaluations and treatments of nasal bone fracture have been mainly focused on aesthetic aspect, but nose has an important role as an airway. The purpose of this study was evaluation of nasal bone fractures in the view of nasal obstruction and its improvement after reduction. Acoustic rhinometry was applied to the 77 nasal bone fractured patients who received closed reduction from August 2002 to July 2003 and received closed reduction. This was tested twice, before and 6 days after reduction, for all 77 patients and additional acoustic rhinometry was also possible in 26 patients after 6 months. The analysis of acoustic rhinometry were based on data of minimal cross-sectional area(MCA) according to fracture sites(one side, both side and tip) and septal displacement. Mean MCA for all cases before reduction was $0.43{\pm}0.21cm^2$, which was 19% decrease compared to normal adult data($0.53{\pm}0.12cm^2$). Depending on fracture sites the MCA were $0.45{\pm}0.16cm^2$ for one side fracture, $0.35{\pm}0.18cm^2$ for both side fracture, and $0.42{\pm}0.25cm^2$ for tip fracture. The patients with septal displacement showed more severe obstruction than ones without septal displacement, $0.26{\pm}0.26cm^2$ and $0.46{\pm}0.10cm^2$, respectively. The MCA was improved up to $0.50{\pm}0.22cm^2$ after reduction and showed slight decrease after 6 month($0.48{\pm}0.23cm^2$). Based on the results of this study, nasal bone fracture really caused airway obstruction(19% decrease). Both side fracture showed more profound decrease than one side fracture and septal displacement was an important parameter which causes nasal obstruction. Closed reduction improved MCA by 14% right after reduction, and 11% after 6 month follow up.

The Result of Open Reduction and Fixation in Sternal Fracture with Displacement (흉골 전위골절에 대한 수술적 정복고정술의 결과)

  • Kim, Young-Jin;Cho, Hyun-Min
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.175-179
    • /
    • 2010
  • Purpose: Sternal fractures after blunt thoracic trauma can cause significant pain and disability. They are relatively uncommon as a result of direct trauma to the sternum and open reduction is reserved for those with debilitating pain and fracture displacement. We reviewed consecutive 11 cases of open reduction and fixation of sternum and tried to find standard approach to the traumatic sternal fractures with severe displacement. Methods: From December 2008 to August 2010, the medical records of 11 patients who underwent surgical reduction and fixation of sternum for sternal fractures with severe displacement were reviewed. We investigated patients' characteristics, chest trauma, associated other injuries, type of open reduction and fixation, combined operations, preoerative ventilator support and postoperative complications. Results: The mean patient age was 59.3years (range, 41~79). The group comprised 6 male and 5 female subjects. Among 11 patients who underwent open reduction and fixation for sternal fracture with severe displacement, 6 cases had isolated sternal fractures and the other 5 patients had associated other injuries. Sternal fractures were caused by car accidents (9/11, 81.8%), falling down (1/11, 9.1%) and direct blunt trauma to the sternum (1/11, 9.1%), respectively. 3 of the 7 patients (42.9%) who underwent sternal plating with longitudinal plates showed loosening of fixation. Otherwise, none of the 4 patients who underwent surgical fixation using T-shaped plate had stable alignment of the fracture. Conclusion: Sternal fractures with severe displacement need to be repaired to prevent chronic pain, instability of the anterior chest wall, deformity of the sternum, and even kyphosis. In the present study, a T-shaped plate with a compression-tension mechanism constitutes the treatment of choice for displaced sternal fractures.

Reduction of Bowed Tibia Fracture by Fixation with Kirschner and Cerclage Wires in a Dog: A Case Report (Kirschner 철사와 원형 철사를 이용하여 개의 휘어진 경골 골절을 정복한 증례)

  • Uhm, Mi-Young;Kim, Young-Ki;Wang, Ji-Hwan;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.25 no.5
    • /
    • pp.408-410
    • /
    • 2008
  • A four months old, 3.6 kg intact female Miniature Dachshund dog was referred for non-weight bearing lameness at right hind limb due to car accident. On physical examination, the patient was non-weight bearing on the right hind leg and had moderate swelling in the proximal to middle tibia region. There was palpable crepitus. Radiographs revealed a slightly displaced, spiral, oblique fracture involving the proximal diaphyseal region of the right tibia. Fibular fracture was also noted. Internal fixation was performed to repair the fracture. Due to bowed shape of fractured tibia, it was not possible to apply K-wire, containing appropriate diameter ($60{\sim}80%$ of bone marrow diameter) for intramedullary fixation. We fixed the bowed tibia fracture using a smaller diameter (30% of bone marrow diameter) K-wire with cross pins and cerclage wires. Four weeks after the operation, radiographs demonstrated healing of the tibia fracture as well as the fibular fracture.