• Title/Summary/Keyword: 골재

Search Result 2,658, Processing Time 0.03 seconds

A Study on the Nano Silica-Sol Coating for Improving Performance of Recycled Aggregate (순환골재의 성능향상을 위한 나노실리카졸의 코팅에 관한 연구)

  • Kim, Seong-Soo;Lee, Jeong-Bae;Ko, Ji-Soo;Kim, Il-Kon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.84-90
    • /
    • 2013
  • In this study we propose an effective method, Coating processing methods, which can improve the quality of recycled aggregate relatively easily without new equipment investment and complex treatment process and verify the improved effect using the devised method, Coating processing methods. To attain the research aim we used adequately diluted silicate solution for coating and carried out several property valuation for twelve types of material with different coating method. Also we formed concrete with coated aggregates which showed the best property. In conclusion the aggregates with the method of repeated impregnation in the silicate and drying showed the most excellent quality while other coating methods also resulted in an improvement of aggregate quality but failed to meet the KS Standard. Lastly with the optimal material we could obtain the approved compressive strength from the concrete allowing it to be utilized for road facility of which standard compressive strength of design is under 24MPa.

Flexural Performance of Reinforced Concrete Beams with Recycled Aggregates Suffering from Sustained Load (지속하중을 경험한 철근콘크리트 보의 골재 종류에 따른 휨거동 특성)

  • Ji, Sang-Kyu;Yun, Hyun-Do;Kim, Sun-Woo;Lee, Eon-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.135-143
    • /
    • 2007
  • This paper presents results of an experimental study designed to investigate the effect of sustained load on the flexural performance of reinforced recycled aggregate concrete beams. In this experimental program, three beams with recycled aggregate replacement percentages(natural 100%, recycled coarse aggregate 100%, recycled fine aggregate 50%) were tested up to failure after sustained loading($0.5M_n$) for one year. The experimental results showed that reinforced concrete beams using recycled aggregate(water absorption : 1.86~3.64%) concrete showed the same flexural performance as that of natural aggregate concrete beam. Current the ACI code underestimated experimental obtained ultimate flexural strength of beams irrespective of usage of recycled aggregates.

Study on the Distribution Status of Construction Aggregates in Incheon Metropolitan City and Nearby Areas (인천광역시 및 인근 지역의 건설용 골재 유통현황 분석 연구)

  • Chul-Seoung Baek;Byoung-Woon You;Kun-Ki Kim;Yu-Jeong Jang;Jin-Young Lee
    • Economic and Environmental Geology
    • /
    • v.57 no.2
    • /
    • pp.219-231
    • /
    • 2024
  • A survey of concrete plants in Incheon Metropolitan City and Gyeonggi Province was used to conduct an analysis of aggregate transport distance and production forms, as well as to evaluate the features and current status of aggregates distribution. As a result, areas such as Incheon, Siheung, Bucheon, Gimpo, and Siheung, where the distance to the demand points is less than 20 km, exhibited bidirectional distribution whereas Paju, Yongin, Yangju, and Pocheon, with distances ranging from 20 to 50 km is showed a unidirectional distribution pattern supplying aggregates exclusively to Incheon. Survey on manufacturing forms, more than 85% of the gravel dispersed in the Incheon area is made up of crushed aggregates derived from rocks discharged at construction sites indicating a considerable skew in supply chain. These findings are predicted to have a detrimental influence on aggregate supply in the long run, necessitating policy changes targeted at building an optimal aggregate distribution market.

Analyze of Thermal Resistivity Characteristics for Recycled Aggregates (순환골재의 열저항특성 분석)

  • Kim, Kyoungyul;Hong, Sungyun;Lee, Daesoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.164.2-164.2
    • /
    • 2010
  • KEPCO에서는 발전소로부터 생산되는 전력을 각 가정에 공급하기 위하여 전력선을 설치하고 있다. 이 전력선은 지상과 지중에 동시에 설치되고 있으며, 지상에 위치한 전력선을 가공선이라 한다. 지중에 설치된 전력선을 지중선이라 하며, 지중선을 설치하기 위한 공사를 지중화공사라 한다. 전력선은 전력이 통전될 때 일정한 온도 이상의 열이 발생하게 되며 이 열이 신속하게 외부로 빠져나가야지만 전력수송효율이 떨어지지 않게 된다. 지중화공사는 대부분 도로를 재굴착하여 설치하게 되며, 전력선을 설치한 후 주변 되메움재로는 모래를 이용하고 있다.하지만 최근 들어 모래의 수급이 딸리고, 가격이 높아지고 있는 관계로 이의 대체재료가 필요한 실정이다. 이에 본 연구에서는 전력선 되메움재인 모래의 대체재료로 건설폐기물의 일종이었던 순환골재를 이용하기 위하여 열저항특성을 분석하였다. 이미 순환골재는 2005년부터 공공 공사에 의무적으로 사용하도록 규정이 되어 있어 도로 또는 콘크리트 골재로 사용하고 있다. 순환골재를 전력선 되메움재로 사용하기 위해서는 열저항온도(thermal resistivity)가 $120^{\circ}C$-cm/W 이하가 되어야만 전력선 효율이 떨어지지 않기 때문에 이를 만족하는 것이 매우 중요하다. 이를 위해 QTM-500 장비를 이용하여 순환골재의 열저항 특성실험을 시행하였다. 실험의 원활한 수행을 위하여 순환골재의 입도는 5.0mm 이하로 제한하였으며, 인자로는 다짐도와 함수비를 중요한 인자로 선택하였다. 분석결과, 다짐도 및 함수비는 순환골재의 열저항온도에 영향을 미치는 주인자로 나타났으며, 일부 교호작용도 존재하는 것으로 나타났다. 향후 실험결과를 바탕으로 현장 실증실험을 수행할 예정이며, 본 연구결과는 KEPCO의 순환골재 이용기준수립에 활용할 예정이다.

  • PDF

Relation Between Water Content Ratio and Fire Performance of Class 1 Structural Light Weight Aggregate Concrete (1종 경량골재콘크리트의 함수율과 내화특성)

  • Song, Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.321-327
    • /
    • 2014
  • Structural light weight aggregate concrete are made with both coarse and fine light weight aggregates, but it is common with the high strength concrete to replace all or part with normal weight sand be called class 1 structural light weight aggregate concrete. Fire resistance of structural light weight aggregate concrete are determined by properties of high water content ratio and explosive spalling. Especially, structural light weight aggregate concrete is occurred serious fire performance deterioration by explosive spalling stem from thermal stress and water vapor pressure. This study is concerned with experimentally investigating fire resistance of class 1 structural light weight concrete. From the test result, class 1 structural light weight concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

A Study on the Property Estimation of Recycled Coarse Aggregate and Characteristic of Recycled Aggregate Concrete Using the Surface Coated Treatment Method (표면처리방법을 이용한 순환 굵은골재의 물성 평가 및 순환골재 콘크리트의 특성 연구)

  • Kim, Nam Wook;Kim, Hyeok Jung;Bae, Ju Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.603-609
    • /
    • 2008
  • The recycled aggregates which were produced from the waste concretes have the disadvantages of inferior properties for natural aggregate. Therefore, in order to reuse the recycled aggregate it must be solved to improve the quality of recycled aggregate. In this study, the quality of recycled aggregate was improved by the surface treatment method using the colloidal silica solution. And, in order to examine the possibility of reusing the surface coated recycled aggregate in constructing concrete structures, we studied the mechanical properties and durability of the concrete using the surface coated recycled aggregates and the other concrete.

A Study on the Analysis Method of Soil Dust Included in the Aggregate Fines (골재 미립분에 포함된 토분의 분석방법 고찰)

  • Min, Tae-Beom;Kim, In;Lee, Jae-Sam;Baek, Chul-Seoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.257-258
    • /
    • 2023
  • As a result of examining research contents related to soil excretion being studied in Korea, there are five methods for soil excretion testing. As a result of analyzing the correlation between each test method and concrete compressive strength, the chemical test method and the Methylene blue test showed a high correlation index.

  • PDF

Basic Study on the Serviceability of Structural Concrete according to Replacement Ratio of Recycled Aggregate (순환굵은골재 치환율에 따른 구조용 콘크리트 사용성에 관한 기초적 연구)

  • Jang, Hyun-Suk;Hong, Seong-Uk;Lee, Young-Taeg;Cho, Young-Sang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.521-524
    • /
    • 2011
  • 본 논문에서는 순환골재에 대하여 구조용 적용성 검증을 목표로 하였으며, 천연골재와 순환골재 치환율에 따른 압축파괴강도와 압축강도증가에 따른 파속도의 상관관계를 비교 분석하였다. 설계기준강도 21, 27, 35MPa에 순환굵은골재 치환율 0, 30, 50, 100%를 적용하여 설계기준강도에 따른 순환굵은골재 치환율의 배합을 총 12가지로 설정하였다. 재령160일까지의 압축파괴강도의 변화를 대기양생 공시체, 수중 양생공시체 그리고 코어공시체를 이용하여 비교하였고, 모의부재(800${\times}$800${\times}$200mm)를 통하여 재령160일까지의 초음파속도를 측정하였다. 압축파괴실험을 통하여 취득한 데이터를 비교해 본 결과 순환굵은골재 치환율에 따른 강도저하현상은 나타나지 않았다. 또한, 재령일에 따른 강도 증가와 함께 파속도도 같이 증가함을 알 수 있었다.

  • PDF

Water absorption characteristics of artificial lightweight aggregates preparedby pre-wetting (프리웨팅된 인공경량골재의 흡수 특성)

  • Kim, Yoo-Taek;Jang, Chang-Sub;Ryu, Yug-Wang
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.2
    • /
    • pp.82-86
    • /
    • 2011
  • Lightweight aggregate which is composed of sintered polycrystalline materials usually has a certain portion of pores inside of it. Because of such a structural characteristics, it tends to that movement of water in aggregate shows an abnormal behavior against the change of outside environment. In general, water movement behavior is controlled by porosity, distribution of pore size; however, dense surface layer will also affect water movement behavior in case of artificially sintered aggregates. Factors affecting water movement behavior in the aggregate are pore distribution, pore shape, pre-wetting method, etc. In this study, absorption characteristics of aggregate under the pressure and absorption rate according to water dipping time are analyzed for the basis of pressure pumping of lightweight concrete. Two kinds of aggregates were used for the test: one is made by 'L' company in Germany and the other is of our own made at the pilot plant in Kyonggi University. Absorption rate of aggregate is measured according to water dipping time, vacuum pressure, and quenching condition. Absorption rate of aggregate with $300^{\circ}C$ quenching is higher than that of aggregate with 24 hr water dipping. Generally the more vacuum the higher water absorption rate. Water absorption rate of 'L' aggregate under -300 mmHg is 54 % higher than that of aggregate with 24 hr water dipping; however, only 2 % increase in water absorption was measured for the K622 and K73 which were of our own.

A Study on the Properties of Recycled Concrete Using Recycled Fine Aggregates with different Removal formulas of Powder In Aggregate (미분 제거방식이 다른 2종의 재생 잔골재가 콘크리트외 특성에 미치는 영향)

  • Lee Mun-Hwan;Lee Sea-Hyun;Shim Jong-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.95-104
    • /
    • 2005
  • The research conducted to study the potential practicability of recycled aggregate concrete by analyzing the characteristics of concretes made of recycled quality aggregates produced by wet and dry process has found the following results. The air content of recycled aggregate concrete increased with increase of the substitut on rate due to mortar included while producing recycled aggregates. However, the concretes with aggregate produced by dry process had relatively low rate of increase in air content. The slump showed generally decreasing trend as the substitution rate of recycled aggregate increased regardless of the wet or dry process. It was assumed that the mortar particles remained in recycled aggregate absorbed the surplus hydration in concrete and decreased fluidity The compressive strength generally decreased as the substitution rate of recycled aggregate increased, however there was an increasing trend as well due to decreasing effect of water-cement ratio when the substitution rate of recycled aggregate reached 25, 50% after mix. This phenomena also appeared in early age, which meant that recycled aggregate concrete should not be retarded in setting when applied in the field. The tensile strength also reached the maximum when wet or dry recycled aggregate replaced with 25%. To conclude, recycled aggregates for concrete produced by wet or dry process are expected to demonstrate essential characteristics of concrete without significant decline in physical or dynamic quality when the substitution rate is below 25% although there are variations subject to water-cement ratio. However, slight differences are expected due to types of recycled aggregate and physical quality.