• Title/Summary/Keyword: 골반 방사선치료

Search Result 192, Processing Time 0.038 seconds

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

The Production, Distribution, and Utilization of Rice in Japan (일본의 쌀 생산, 유통 및 이용 현용)

  • Inouchi, Naoyoshi
    • Food preservation and processing industry
    • /
    • v.1 no.1
    • /
    • pp.17-26
    • /
    • 2002
  • 일본은 기후적으로도 쌀의 생산에 적합하며 쌀은 일본의 주곡이다. 1893년 국립농업연구소가 설치된 이래로 쌀은 품질과 단보당 생산량이 꾸준히 개선되어와 116의 노동시간으로 생산량은 2.5배의 증가를 가져왔다. 이러한 진전은 재배방법의 개선, 비료, 농약, 재배기술, 기계화, 관개배수, 농지개량 등의 요인들로 볼 수 있다. 현재 일본에서 생산되고 있는 주요 쌀 품종으로는 코시히카리($35.5\%$), 히토메보레($9.7\%$), 히노히카리($9.0\%$), 아키다코마치($8.5\%$), 키라라($4.8\%$) 등 10여 품종이며 최근에는 형질전환 품종의 연구와 함께 생물공학적 연구 ,생리, 품질, 곤충과 잡초, 토양, 식품가공 등 기본적인 연구에 심혈을 기울이고 있다. 새로운 형태의 쌀 품종으로는 냉동조리쌀밥, 초밥, 레토르트룡 쌀 등 가공용으로 적합하도록 하기 위하여 아밀로오즈의 함량을 $5-15\%$로 낮춘 쌀이나 카레, 필라프, 튀김 쌀 등의 용도에 적합하도록 아밀로오스의 함량을 $30\%$이상으로 높인 쌀뿐만 아니라 곡립의 크기와 길이 등을 변형시킨 쌀, 유색미, 향미, 단백질 함량 조절 쌀, 거대 배아미, lipoxygenase 활성을 없앤 쌀, 단맛나는 쌀 등이 연구, 생산되고 있다. 일본에서의 쌀이용은 먼저 가공용 쌀을 들 수 있다. 밥, 청주, 스낵, 쌀가루, 미소발효 등 다양하게 이용이 되고 있으며 parboiled rice와 이의 색과 향을 개선한 converted rice, 현미를 이용한 가공쌀, 쌀빵, 현미가루, 세척미, 쌀국수, 쌀스낵, 당과, 죽, 쌀은 채소아 함께하는 타키코미고한, 초밥, 냉동쌀밥, 무균포장밥, 건조밥, 즉석밥 등 매우 다양하다.는 일, 쌀 재배구조 조정과 함께 높은 미질을 가지는 품종육종, 기계화를 비롯한 경작기술의 발달, 쌀과 부산물 가공기술의 개발연구, 특정기능을 함유하는 유전공학적 기술의 적용, 토지와 도시화 그리고 식량순환에 시스템의 개혁 등 과학기술을 고양하는 일 등을 들 수 있다.하는데 도움이 되리라 생각된다.=0.002)가 통계적으로 유의한 인자였다. 결론 : 본 기관에서 시행되어진 근침윤성 방광암에 대한 방광보존치료법은 기존의 근치적 방광절제술에 비하여 대등한 치료성적을 내는 동시에 $63\%$에서 장기보존이 가능하였다. 따라서 본 치료법이 방광암의 치료에 적극적으로 적용되어야 할 것으로 생각하며 향후 여러 기관이 참여하는 활발한 연구를 통해 한국인에게 가장 적절한 치료법을 개발해야 될 것으로 생각한다. B2+3, C1, C2+3군에서 수술달독군과 방사선치료 추가군의 골반종양제어율은 각각 $79\%$$75\%$ (p=0.88), $100\%$$100\%,\;44\%$$68\%$ (p=0.01)이었다. 전체 환자를 대상으로 다요인 분석을 시행한 결과 생존율과 무병생존율에 병기만이 유의하였고 두 치료 군에서도 역시 병기가 유의한 인자로 나타났다. 전체환자에서 골반종양제어율에 유의한 예후인자로 다요인분석을 시행한 결과 병기와 수술방법이 유의하였다. 수술단독군에서는 병기만이 유의하였고 방사선치료 추가군에서는 수술방법만이 유의하여 복부회음절제술군의 골반종양재발률이 높았다. 결론 : 본 후향적 연구에서 수술 후 보조적 방사선치료를 시행하여 수술단독군에 비해 병기 C2+3군에서 골반종양제어율이 향상되었음을 알 수 있었다. 그러나 병기 B2이상의 모든 환자에서 골반종양제어율 뿐만 아니라 생존율의 향상을 가져오기

  • PDF

A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer (골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교)

  • Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.7-12
    • /
    • 2019
  • Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.

Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.

Palliative Irradiation Using Helical Tomotherapy in Recurrent Pelvic Tumors with Prior Radiotherapy (방사선치료 후 재발한 골반암에서 토모테라피를 이용한 고식적 재치료)

  • Kay, Chul-Seung;Yoo, Eun-Jung;Kim, Ji-Hoon;Ro, Duck-Young;Kim, Ki-Jun
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.133-140
    • /
    • 2010
  • Purpose: We retrospectively investigated the effect of irradiation using helical tomotherapy in recurrent pelvic tumors that underwent prior irradiation. Materials and Methods: Fourteen patients with recurrent pelvic tumors consisting of rectal cancer (57.1%), cervical cancer (35.7%) and cancer with an unknown origin (7.1%) were treated with tomotherapy. At the time of irradiation, median tumor size was 3.5 cm and 7 patients complained of pain originating from a recurrent tumor. The median radiation dose delivered to the gross tumor volume, clinical target volume, and planning target volume was 50 Gy, 47.8 Gy and 45 Gy, respectively and delivered at 5 fractions per week over the course of 4 to 5 weeks. Treatment response and duration of local disease control were evaluated using the Response Evaluation Criteria in Solid Tumors (ver. 1.0) and the Kaplan-Meyer method. Treatment-related toxicities were assessed through Common Terminology Criteria for Adverse Events (ver. 3.0). Results: The median follow-up time was 17.3 months, while the response rate was 64.3%. Symptomatic improvement appeared in 6 patients (85.7%). The median duration time of local disease control was 25.8 months. The rates of local failure, distant failure, and synchronous local and distant failure were 57.1%, 21.4%, and 7.1%, respectively. Acute toxicities were limited in grade I or II toxicities, except for one patient. No treatment related death or late toxicity was observed. Conclusion: Helical tomotherapy could be suggested as a feasible palliative option in recurrent pelvic tumors with prior radiotherapy. However, to increase treatment effect and overcome the limitation of this outcome, a large clinical study should be performed.

Reirradiation in Rcurrent Cervical Cancer Following Definite Radiation Therapy (근치적 방사선치료 후 재발한 자궁경부암의 재 방사선치료)

  • Kim, Jin-Hee;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.230-236
    • /
    • 2001
  • Purpose : To evaluate treatment results in terms of local control, complications and survival after reirraidiation in recurrent cervical cancer following definite radiation therapy. Material and methods : From November 1987 through March 1998, eighteen patients with recurrent cervical cancer following definite radiation therapy were subsequently treated with reirradiation at Keimyung University Dongsan Medical Center. In regard to the initial FIGO stage, one patient was stage la, five were stage IIa, three were IIb, two were IIb and two were IVa. The age range was 37 to 79 years old with median age of 57. The time interval from initial definite radiation therapy to recurrence ranged from 6 to 122 months with a median of 58 months. The recurrent sites were the uterine cervix in seven patients, vagina in ten and pelvic lymph node in one. Reirradiation was peformed with external radiation and intracavitary radiation in twelve patients, external radiation and implantation in four and external radiation alone in two. The range of external radiation dose was $2,100\~5,400\;cGy$ and the range of the total radiation dose was $3,780\~8,550\;cGy$. The follow-up periods ranged from 8 to 20 months with median of 25 following reirradiation. Results : Fourteen of eighteen patients $(78\%)$ had local control just after reirradiation. The two year disease free survival (2YDFS) rate was $53.6\%$. There were statistically significant differences in the 2YDFS according to both recurrent site (2YDFS $28.5\%$ in uterine cervix, $71.4\%$ in vagina, (p=0.03)) and the total dose (2YDFS $71.8\%$ in >6,000 cGy , $25\%$ in $\leq6,000$ cGy, p=0.007). Seven of ten patients who were followed for more than 20 months remain alive and disease free (7/18, $39\%$). Patients treated with external radiation and intracavitary radiation had a higher rate of 2YDFS. Seven patients including 4 patients with no local control experienced local failure in the uterus or vagina and two patients died with distant metastasis. Complications included rectal bleeding in 3 patients, bowel obstruction treated with surgery in two, hematuria in one, radiation cystitis in two, soft tissue swelling in two and vaginal necrosis spontaneously healed in one. There was no statistical difference in complications according to the total dose or the time to recurrence from initial radiation. Conclusion : In patients with recurrence following definite radiation therapy in the uterine cervical cancer, reirradiation may be effective but requires an effort to reduce radiation induced severe complications.

  • PDF

The Results of Hvperfractionated Radiation Therapy Combined with Taxol for Paraaortic Node Recurrence in Cervix Cancer (대동맥주위 림프절에 재발된 자궁경부암에서 Taxol을 병행한 과분할 방사선치료의 결과)

  • Kim, Jun-Sang;Jang, Ji-Young;Kim, Jae-Sung;Kim, Sam-Yong;Cho, Moon-June
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.27-31
    • /
    • 2000
  • Purpose : The aim of this study was to investigate treatment results, toxicity and efficacy of hypefractionated radiation therapy combined with paclitaxel for paraaortic node recurrence in cervix cancer. Materials and Methods: Between September 1997 to March 1999, 12 patients with paraaortic node recurrence in cervix cancer who previously received radical or postoperative radiotherapy were treated with hypefractionated radiation therapy combined with paclitaxel. Of these, 2 patients who irradiated less than 30 Gy were excluded, 10 patients were eligible for this study. Median age was 51 years. Initial FIGO stage was 1 stage IBI, 2 stage IIA, 7 stage IIB. For initial treatment, 7 patients received radical radiotherapy and 3 received postoperative radiotherapy. The paraaortic field encompassed the gross recurrent disease with superior margin at T12, and inferior margin was between L5 and S1 with gap for previously pelvic radiation field. The radiation field was initially anterior and posterior opposed field followed by both lateral field. The daily dose was 1.2 Gy, twice daily fractions, and total radiotherapy dose was between 50.4 and 60 Gy(median, 58.8 Gy). Concurrent chemotherapy was done with paclitaxel as a radiosensitizer. Dose range was from 20 mg/m$^{3}$ to 30 mg/m$^{3}$ (median, 25 mg/m$^{3}$), and cycle of chemotherapy was from 3 to 6 (median, 4.5 cycle). Follow-up period ranged from 3 to 21 months. Results : Interval between initial diagnosis and paraaortic node recurrence was range from 2 to 63 months (median, 8 months). The 1 year overall survival rate and median survival were 75$\%$ and 9.5 months, respectively. The 1 year disease free survival rate and median disease free survival were 30$\%$ and 7 months, respectively. At 1 month after treatment, 4 (40$\%$) achieved a complete response and 6 (60$\%$) experienced a partial response and all patients showed response above the partial response. There was distant metastasis in 6 patients and pelvic node recurrence In 2 patients after paraaortic node irradiation. There was 2 patients with grade 3 to 4 leukopenla and 8 patients with grade 1 to 2 nausea/ vomiting which was usually tolerable with antlemetic drug. There was no chronic complication in abdomen and pelvis during follow up period. Conclusion : hypefractionated radiation therapy combined with paclitaxel chemotherapy diosensitizer showed high response rate and few complication rate in paraaortic node recurrence in cervix cancer Therefore, present results suggest that hypefractionated radiation therapy combined with paclitaxel chemotherapy can be used as optimal treatment modality in this patients.

  • PDF

Implementation of KV Cone Beam CT for Image Guided Radiation Therapy (영상유도 방사선치료에서의 KV 콘빔CT 이용)

  • Yoo, Young-Seung;Lee, Hwa-Jung;Kim, Dae-Young;Yu, Ri
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • Purpose: The aim of this study was the clinical implementation of IGRT using KV CBCT for setup correction in radiation therapy. Materials and Methods: We selected 9 patients (3 patient for each region; head, body, pelvis)and acquired 135 CBCT images with CLINAC iX (Varian medical system, USA). During the scan, the required time was measured. We analyzed the result in 3 direction; vertical, longitudinal, lateral. Results: The mean setup errors at the couch position of vertical, lateral, and longitudinal direction were 0.07, 0.12, and 0.1 cm in the head region, 0.3, 0.26, and 0.22 cm in the body region, 0.21, 0.18, and 0.15 cm in the pelvis region respectively. The mean time required for CBCT was $6{\sim}7$ minute. Conclusion: The CBCT on the LINAC provides the capacity for soft tissue imaging in the treatment position and real time monitoring during treatment delivery. With presented workflow, the setup correction within reasonable time for more accurate radiation therapy is possible. And it's image can be very useful for adaptive radiation therapy(ART) in the future with improved image quality.

  • PDF

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Positional Change of the Uterus during Definitive Radiotherapy for Cervix Cancer (자궁경부암의 방사선치료 시 자궁의 크기와 위치 변화)

  • Park, Won;Huh, Seung-Jae;Lee, Jeung-Eun
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.135-142
    • /
    • 2003
  • Purpose: The purpose of this study was to investigate the positional change of the uterus during radiotherapy. Materials and Methods: Between 1997 and 2001, 47 patients received definitive radiotherapy for cervical cancer at the Samsung Medical Center. For each patient, two MRI scans were taken; one before and the other 3$\~$4 weeks after the radiotherapy treatment. In T2 weighted MRI images, the positional change of the uterine was quantified by measuring six quantities; the distance from the cervix os to the isthmus of the uterus (Dcx), the maximum length from the isthmus of the uterus to the uterine fundus (Dco), the maximum vertical distance of the uterine body (Dco-per), the angle between the vertical line and the cervical canal in the sagittal images (Acx), the angle of the uterine corpus from the vertical line in the sagittal plan (Aco-ap), and the relative angle of the uterine corpus from a fixed anatomical landmark in the axial images (Aco-axi). Results: The mean Dcx values, before and during the treatment, were 36.7 and 27.8 mm, respectively. The Dco deviated by more than 10 mm in 14 cases (29.8$\%$). The change in the Acx ranged from 0.1 to 67.8$^{\circ}$ (mean 13.2$^{\circ}$). The Aco-ap changed by a maximum of 84.8$^{\circ}$ (mean 16.9$^{\circ}$). The differences in the Dcx plus the Dco in the smaller (<4 cm) and larger ($geq$4 cm) tumors were 5.3 and 19.4 mm, respectively. With patients less than 60 years old, or with a tumor size larger than 4 cm, the difference in the Acx was statistically significant. Conclusion: The positional changes of the uterus, during radiation treatment, should be considered in the 3DCRT or IMRT treatment planning, particularly in patients under 60 years of age or in those with a tumor size greater than 4 cm in maximum diameter.