• Title/Summary/Keyword: 고체전극

Search Result 155, Processing Time 0.023 seconds

Fabrication of Solid Electrolyte Oxygen Sensors Using $CaF_{2}$ and their Characteristics ($CaF_{2}$를 이용한 고체전해질 산소센서의 제조및 그 특성)

  • Lee, Jae-Hyun;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.40-49
    • /
    • 1994
  • Potentiometric cell oxygen sensors using $CaF_{2}$ were fabricated for monitering the oxygen partial pressure in the low temperature range ($300^{\circ}C{\sim}$500^{\circ}C). The disk type oxygen sensors consist of a reference electrode: Air($O_{2}:21%$)|Pt, a solid electrolyte $CaF_{2}$, and a sensing metel Pt electrode. And the change in open circuit emf of the disk type cell was about 45mV for the oxygen concentration range, $0.1%{\sim}10%$, at the cell temperature of $400^{\circ}C$. Also, the reference electrode incorporated type sensor showed the change of 40mV for 0.1% to 10% oxygen partial pressure range.

  • PDF

The preparation of electroconductive Nylon/Spandex stretch fabric (I) - Changes of conductivity with extension (전도성 Nylon/Spandex 스트레치 직물의 제조(I) - 신장에 따른 전도도의 변화)

  • 박현진;오경화;김성훈
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.314-315
    • /
    • 2001
  • 전기 전도성 고분자는 폴리 아세틸렌을 적절한 electron withdrawing group이나 electron donating group을 이용하여 도핑하면 전도도의 증가를 가져온다는 보고 이래로 활발하게 연구되어져 왔다. 그 중에서 폴리피롤은 높은 전도도와 산화안정성, 인체에 무해한 특성 때문에 여러 분야에 응용되고 있으며 분자전자장치나 고체 배터리의 전극, 축전기의 고체 전해질, 전자파 차폐 재료, ion센서, 위장막의 제조 등의 용도전개 잠재력이 무궁하다. (중략)

  • PDF

Study on AC creepage discharge characteristics on polluted solid dielectrics (오염된 고체절연물의 AC 연면 절연파괴특성 분석)

  • Kim, J.T.;Seo, C.W.;Park, H.S.;Kim, B.D.;Jang, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1169-1170
    • /
    • 2015
  • 공기를 주 절연매질로 사용하는 전력기기의 소형화 추세속에서 제품의 절연성능을 확보하기 위해 '절연배리어'인 고체절연물이 사용된다. 고체절연물의 연면 절연성능은 운전 환경에서 발생된 수분 및 오염원 등에 영향을 받기 쉽기 때문에, 다양한 오염도 조건에서 고체절연물의 연면 절연파괴특성 분석이 필요하다. 본 논문에서는 전력기기에 폭넓게 적용되는 있는 고체절연물에 대하여 평등전계가 모의된 평판 - 평판 전극 실험 조건에서 연면거리 및 오염도를 정량화한 전기전도도에 따른 AC 연면 절연파괴특성을 분석하였다. 그 결과, AC 연면 절연파괴전계는 고체절연물 재질에 관계없이 단(短) 갭에서 연면거리에 대한 의존성을 거의 보이지 않았다. 또한, PC 연면 절연파괴전계는 BMC 및 에폭시 대비 높았으며, 이것은 재질에 따른 연면 절연파괴 형태 및 표면의 소수성 차이와 관련이 있는 것으로 사료된다.

  • PDF

Impedance measurements of solid electrolyte (고체 전해질의 임피던스 측정법)

  • 구할본;김현철
    • Electrical & Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.543-548
    • /
    • 1994
  • 전기화학반응은 일반적으로 반응속도가 전류에, 반응의 구동력이 과전압에 대응하기 때문에 전류 또는 전위의 경시적 변화로 부터 적극 반응기구나 반응의 과정을 해석하는 법이 널리 이용되고 있다. cyclic voltammetry과 chrono-potentiometry을 비롯한 시간영역에서의 해석에 대해, 전극계의 동적인 특성을 주파수 영역에서 해석하는 것도 가능하며 교류임피던스법이 가장 잘 알려진 방법이다. 여기서는 교류임피던스법의 고찰법, 기본적인 측정법, 몇개의 계에 있어서 임피던스 특성 및 그 방법의 새로운 전개에 대해서 설명한다.

  • PDF

Contact Charging and Electrphoresis of a Glassy Carbon Microsphere (유리상 탄소입자의 직접 접촉충전에 의한 전기영동 현상연구)

  • Choi, Chang Yong;Im, Do Jin
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.568-573
    • /
    • 2016
  • We investigated the charging characteristics of a conducting solid sphere (glassy carbon sphere) comparing with that of a water droplet and check the applicability of the perfect conductor theory. For the systematic research, sphere size, applied voltages, viscosity of the medium were changed and the results were compared with that of corresponding water droplets and the perfect conductor theory. Basically, a glassy carbon sphere follows the perfect conductor theory but the charging amount was lower as much as 70~80% of theoretical prediction value due to oil film formed between electrode and a carbon sphere. We hope this result provides basic understandings on the solid sphere contact charging phenomenon and related applications.

Numerical Study on Oxygen Depletion Characteristics of Porous Cathodes in Anode-Supported Solid Oxide Fuel Cells (음극지지 고체산화물 연료전지 다공성 양극에서의 산소고갈 특성에 관한 수치해석 연구)

  • Shin, Dongwoo;Nam, Jin Hyun;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.257-268
    • /
    • 2017
  • This paper proposes an efficient two-dimensional simulation model for solid oxide fuel cells (SOFCs) based on the electrochemical effectiveness model. The effectiveness model is known to accurately predict the current generation performance of SOFC electrodes, by considering the complex reaction/transport processes that occur within thin active functional layers near the electrolyte. After validation tests, the two-dimensional simulation model was used to calculate the distribution of current density and oxygen concentration transverse to the flow channel in anode-supported SOFCs, with which the oxygen depletion characteristics were investigated in detail. In addition, simulations were also conducted to determine the minimum number of grids required in the transverse direction to efficiently obtain accurate results.

A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops (전압강하를 고려한 전기방식 기준 개정에 관한 연구)

  • Ryou, Young-don;Lee, Jin-han;Jo, Young-do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.50-57
    • /
    • 2016
  • According to the urban gas business legislation, cathodic protection systems should be applied for buried steel gas pipelines to prevent corrosion. In advanced countries including United States, the criteria for Cathodic Protection Potential is at least -850mV with respect to a saturated copper/copper sulfate electrode(CSE) when the CP applied, and the IR drops must be considered for valid interpretation. However, the IR drop through the pipe to soil boundary has been neglected in Korea. According to KGS code, a reference electrode must be placed in proximity to gas pipelines possible when measuring the CP potential. In this study, we have installed several solid reference electrodes around the buried pipeline(1.2m depth), lower surface(0.5m depth), and the surface individually in order to measure the CP potentials through the each reference electrode and find out the IR drops according to the location of each reference electrode. We have found the IR drop is the greatest when measuring the CP potential through the electrode placed on the ground and the IR drop is the smallest through the electrode installed near pipeline. Therefore, we have suggested the solid reference electrode should be installed as close as possible to buried pipeline in order to measure the correct CP potential without IR drop. We have also suggested the amendment of CP criteria considering IR drop.

SOx Sensor Using NASICON Solid Electrolyte (NASICON 고체 전해질을 사용한 SOx 가스 감지센서)

  • Choi, Soon-Don;Lee, Kwang-Beum
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.25-34
    • /
    • 1996
  • A SOx sensor using NASICON electrolyte was developed for monitoring of air pollution. The following galvanic cell with $Na_{2}SiO_{3}(Pt)$ reference electrode was assembled : Pt | $Na_{2}SiO_{3}$ | NASICON | $Na_{2}SO_{4}$ | Pt, $SO_{2}$, air $Na_{2}SO_{4}$ was used as an indicator electrode to protect NASICON electrolytes from chemical reaction with $SO_{2}$. The EMFs were measured after injecting $SO_{2}$ in the initial concentrations range of $5{\sim}95ppm$ at $400{\sim}550^{\circ}C$. The measured and calculated potentials were in good agreement above $500^{\circ}C$. However, the cells were unstable below $500^{\circ}C$, most likely due to incomplete attainment of chemical equilibrium. Response time was within 10 min. Based on the stability and response time of this cell, the NASICON solid electrolyte with $Na_{2}SiO_{3}(Pt)$ as the reference electrode and $Na_{2}SO_{4}$ (Pt)as the indicator electrode showed the possibility of a reliable, inexpensive commercial solid-state SOx sensor.

  • PDF

A Study on 1-Butene Oxidation over Vanadium Oxide Electrode (바나듐산화물 전극상에서 1-부텐의 산화반응 연구)

  • Park, Seungdoo;Lee, Hag-Young;Hong, Suk-In
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.523-528
    • /
    • 1998
  • The electrochemical characteristics of $V_2O_5$ as working electrode were studied in the cell (1-butene+$O_2$, $V_2O_5{\mid}YSZ{\mid}Ag$, $O_2$) with a YSZ solid electrolyte. The sintering of Ag as a counter electrode was occurred after calcination, and the structure which has the pores of over $3{\mu}m$ was achieved. In particular, the peak of (010) plane of the working electrode on the XRD spectrum which is responsible for selective oxidation appeared after calcination. The major product of 1-butene oxidation over $V_2O_5$ was butadiene. The technique of SEP (solid electrolyte potentiometry) was used to monitor the chemical potential of chemical species adsorbed on the working electrode. Over a wide range of gas compositions of 1-butene and oxygen, open circuit voltage (OCV) exhibited the mixed potential of surface oxygen activity.

  • PDF