• Title/Summary/Keyword: 고주파수작동

Search Result 43, Processing Time 0.028 seconds

Experiments of an acoustic cooling and fabrication of a 40 kHz waveguide (음향 냉각 실험 및 40 kHz 급 웨이브가이드 제작)

  • Hyunse Kim;Euisu Lim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.5
    • /
    • pp.511-516
    • /
    • 2024
  • Recently, refrigerants such as freon gases of conventional refrigerators and air conditioners are regarded as causes of air pollutions and global warming. Thus, a new cooling technology needs to be developed and wave cooling systems are being developed, which use acoustic energies. In this article, for the development of a wave cooling system, acoustic cooling devices, which uses a low frequencies of 385 Hz and 1,150 Hz, were fabricated and experiments were performed. Using these results, a high frequency waveguide, which can be substituted for speakers, was designed using finite element methods and fabricated. As a result, the analysis result of the peak impedance value was 35.5 kHz, which agreed well with the measured value of 37.5 kHz with 5.3 % error.

A Study on the Efficient Tension Estimation of Cables under Ambient Vibration using Minimized Measurement and Signal Processing System (최소화된 계측 및 신호 처리 시스템을 이용한 상시진동 케이블의 효율적인 장력 추정에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.594-603
    • /
    • 2018
  • Recently, according to the development of measurement techniques, it has become possible to take complicated and time-consuming field measurements in a simple and convenient manner. In this background, this study estimated the tension of cables under ambient vibration using minimized measurement and signal processing. The VBDM using video-only by low-cost equipment was used as a minimized measurement. An estimation of the natural frequency using the mirror frequency concept was also proposed to solve the shortage of frequency band in this case. Furthermore, the FDD method was adopted for a natural frequency estimation in the ambient vibration related to field application. Experimental studies using a cable-stayed bridge model were carried out to examine the properties of the mirror frequency and the applicability of FDD with the proposed minimized system. The results showed that FDD for ambient vibration also works properly in an estimation of the natural frequency using the minimized system. In addition, the mirror frequency concept can allow a high natural frequency estimation even in a distorted signal by low-speed recording, which can overcome the limit of the minimized system. Overall, the proposed minimized system can be effective for the tension estimations of a cable under ambient vibration.

Ground Vibration Reduction Technology Using High Damping Polymer Concrete (고 감쇠 폴리머 콘크리트를 활용한 지반진동 저감기술에 대한 연구)

  • Kim, Jeong-Jin;Seok, Won-Gyun;We, Joon-Woo;Ahn, So-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.154-160
    • /
    • 2021
  • Recently, there have been increasing construction works carried out in urban centers, which are inducing frequent artificial vibration in the vicinity of existing structures due to such construction works. moreover, in case of industrial estates, vibration is induced due to operation of machines in the surrounding areas, thereby causing problems. meanwhile, in case of ordinary concrete that compose structure has low level of damping capability for vibration. accordingly, there are difficulties in blocking a wide range of vibrations delivered to the structures from outside including not only vibrations generated in the structures themselves but also ground vibration. recently, numerous studies are being carried out actively on high-damping system that markedly enhanced the damping performances of structures by utilizing polymer concrete in order to block the vibrations delivered to the structures through ground. therefore, this study compared the performances of polymer concrete with those of ordinary concrete, polyurethane pad and foamed rubber pad in order to review its performances in reducing ground vibration. for this purpose, review of FRF and vibration acceleration as dynamic characteristics was made. after comparative verification on the dynamic characteristics is made when polymer concrete and other aforementioned materials are applied to underground structures, the possibility of application of polymer concrete to structures is reviewed.

Analysis of noise source for refrigerant-induced noise in suction and discharge piping systems of compressor installed in air conditioner outdoor unit using wavenumber-frequency decomposition technique (파수-주파수 분리 기법을 통한 에어컨 실외기 압축기 흡배기 배관계 냉매 유발 소음원 분석)

  • Sangjun Park;Sangheon Lee;Cheolung Cheong;Jinhyung Park;Jangwoo Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.5
    • /
    • pp.570-583
    • /
    • 2024
  • The supply of inverter-type air conditioners for cooling in summer and heating in winter is increasing. In addition, since the operating speed of the compressor has been continuously increased for higher efficiency and higher performance, the flow speed of the refrigerant has also increased. As a result, it results in the increase of the relative contribution of flow-born noise to total noise generated from outdoor unit, and this highlights the importance of designing for the noise reduction to addressing flow-borne noise and requires necessary to analyze noise generation mechanisms by flow borne noise. Therefore, in this paper, the noise generation mechanisms by flow borne noise from air conditioner outdoor unit was numerically investigated. The wall pressure field was predicted using Large Eddy Simulation(LES) for the refrigerant flow inside the pipe, and the vibration and radiated noise were predicted using structure and acoustic coupled scheme based Finite Element Method (FEM). In this step, the compressible/in-compressible pressure field were separated using Wavenumber-Frequency Analysis(WFA) for inner pipe wall, and this results were used in analyzing the noise source due to refrigerant flow.

Application of Combustion Stabilization Devices to Liquid Rocket Engine (액체 로켓엔진에서 연소 안정화기구의 적용 효과)

  • Sohn, Chae-Hoon;Seol, Woo-Seok;Lee, Soo-Yong;Kim, Young-Mog;Lee, Dae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.79-87
    • /
    • 2003
  • Application of combustion stabilization devices such as baffle and acoustic cavity to liquid propellant rocket engine is investigated to suppress high-frequency combustion instability, i.e., acoustic instability. First, these damping devices are designed based on linear damping theory. As a principal design parameter, damping factor is considered and calculated numerically in the chambers with/without these devices. Next, the unbaffled chambers with/without acoustic cavities are tested experimentally for several operating conditions. The unbaffled chamber shows the peculiar stability characteristics depending on the operating condition and it is found to have small dynamic stability margin. As a result, the acoustic cavity with the present design has little stabilization effect in this specific chamber. Finally, stability rating tests are conducted with the baffled chamber, where evident combustion stabilization is observed, which indicates sufficient damping effect.

Vulnerability Case Analysis of the High Power Electromagnetic Pulse on Digital Control System (디지털 제어장치의 고출력 전자기펄스에 대한 취약성 사례 분석)

  • Woo, Jeong Min;Ju, Mun-No;Lee, Hong-Sik;Kang, Sung-Man;Choi, Seung-Kyu;Lee, Jae-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.698-706
    • /
    • 2017
  • The risk of high power electromagnetic(HPEM) pulse exposure to the devices used in digital control system such as PLC(programmable logic controller) and communication cable is increasing. In this paper, two different frequency ranges HPEMs were exposed to those control systems to assess the each vulnerability. The vulnerability of the EUTs exposed from HPEM were analyzed and compared with a variation of distances and source power. As the EUTs were exposed to higher level of HPEM, the voltage and communication waveform of the control system had shown a distorted response. And the unshielded twisted pair(UTP) cable connected to the EUTs showed operation failures with induced voltage. However, the foiled twisted pair(FTP) cable shielded the connected device efficiently from the HPEM exposure. Therefore, the necessity of the protection measures against the vulnerability of HPEM exposure for the digital control system used in power facilities and industrial site were verified.

An Experimental Study on Breaking Waves (쇄파 발생에 관한 실험적 연구)

  • 이동연;주성문;최항순
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.1
    • /
    • pp.37-43
    • /
    • 1996
  • Breaking waves were generated in a 2-D flume. A piston-type wavemaker was operated in accordance with signals which consist of elementary harmonics with appropriate phase differences. These phase differences were estimated by using a linear wave theory so that wave crests were to be concentrated at the same position. The stroke of wavemaker was controlled to create plunging-type breaking waves. The signal with small amplitude could not generate breaking waves. In the case of moderate amplitudes, various breaking waves could be obtained. Most of breaking waves were spilling type. Only when the wavemaker was operated with appropriate amplitude, plunging-type breaking waves were generated. The parameters of breaking waves are the wave steepness and the frequency bandwidth. If the central frequency was low, breaking waves were not generated. Based on experimental data, we found that the wave height of breaking inception was H = 0.0113 gT$^2$. We also made computations by using a mixed Euler-Lagrangian scheme under the assumption of potential flow. The numerical results show good agreements with tank measurements.

  • PDF

Design of acoustic meta-material silencer based on coiled up space (지그재그 구조 메타물질을 이용한 음향 소음기 설계)

  • Shim, Ki-Hwoon;Jang, Jun-Young;Kwon, Ho-Jin;Song, Kyungjun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • In this paper, we design an acoustic meta-material silencer that operates at low frequency to reduce noise in duct. A high refractive index meta-material silencer is demonstrated with a combination of zigzag structured thin waveguide and helmholtz resonator, which reduces the speed of sound. Finite Element Method (FEM) analysis via thermo-viscous acoustic mesh is performed in order to calculate thermo-viscous dissipation in sub-wavelength waveguide. Sound power reflection, transmission and absorption coefficients are obtained utilizing 4-Microphone Method. The results show that cut-off frequency and transmission loss can be controlled through adjusting intervals of the zigzag structures. A wide-band acoustic silencer is also suggested by connecting meta-materials in series or parallel.

Analysis of relative contribution of machinery-induced vibration/flow-induced vibration to noise radiation from compressor discharging piping system in air-conditioner outdoor unit (에어컨 실외기 압축기 배기 배관계의 기기 기인 진동/유동 기인 진동의 방사소음에 대한 상대적 기여도 분석)

  • Sangheon Lee;Cheolung Cheong;Jinhyung Park;Jangwoo Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.122-130
    • /
    • 2024
  • Vibration of compressor in the air-conditioner outdoor unit have known to be main noise source radiated from outdoor unit. However, as the operating speed of compressor increase, the relative contribution of flow induced vibration and noise is also increase. In this paper, the numerical method was established to predict fluid-borne noise from compressor discharging pipe of air-conditioner outdoor unit. In this step, numerical result was compared to experimental one to verify numerical method. Additionally, the effects of pressure pulsation of compressor and compressor vibration into radiated noise were investigated in frequency domain. It was confirmed that the compressor vibration contributed to the low frequency band, while the pressure pulsation dose to the high frequency band.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF