• Title/Summary/Keyword: 고주파링크

Search Result 40, Processing Time 0.029 seconds

A High Frequency Link Direct DC-AC Converter for Fuel Cell Power Source (연료전지 발전 시스템용 고주파 링크 DC-AC 컨버터)

  • Song, Y.J.;Park, S.I.;Jeong, H.G.;Han, S.B.;Jung, B.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.245-249
    • /
    • 2005
  • This paper describes a boost converter cascaded high frequency link direct dc-ac converter suitable for fuel cell power sources. A new multi-loop control for a boost converter to reduce the low frequency input current harmonics drawn from fuel cell is proposed. A new PWM technique for the cycloconverter at the secondary to reject the low order harmonics in the output voltages is presented in detail.

  • PDF

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

High Frequency Link PCS for Interfacing with Power Utility System (고주파 링크 전력계통 연계형 PCS)

  • Kim, E.S.;Yoon, G.H.;Kang, S.I.;Cha, I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • Recently, new technologies of the PCS (Power Conditioning System) for energy generating using solar cells or fuel cell are required for smaller unit with low cost and high performance. In this paper, the proposed high frequency AC linked DC/AC converter which consisted of LLC resonant and LF cycloconverter is presented, described and verified through the experimental results of 1kW PCS.

  • PDF

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.

Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology (전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.505-508
    • /
    • 2016
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace lines with high power impulse injection. Our proposed method uses to trace lines with very small power high frequency signal injection. Simulation models for 3-phase power transformers, 3-phase wire lines, and customer loads are described to investigate the transmission characteristics of high frequency power line carrier. Distribution lines have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Analysis of Series Resonant High Frequency Inverter using Sequential Gate Control Strategy (순차식 게이트 구동방식에 의한 직렬 공진형 고주파 인버터 특성 해석)

  • 배영호;서기영;권순걸;이현우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.3
    • /
    • pp.57-66
    • /
    • 1993
  • This research proposes a high frequency series resonant inverter consisting of equivalent half - bridge model in combination with two L-C linked full-bridge inverter circuits using MOSFET. As a output power control strategy, the sequential gate control method is applied. Also, analysis of operating MODE and state equation is described. From the computer simulation results, the inverters and devices can be shared properly voltage and current rating of the system in accordance with series and parallel operations. And it is confirmed that the proposed system has very stable performance.

  • PDF

RF Interference Analysis and Verification in the Synthetic Aperture Radar Satellite System (영상레이더 위성시스템 구조물의 RF 간섭특성 분석 및 검증)

  • Jang, Jae-Woong;Kim, Tae-Yoon;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.187-196
    • /
    • 2009
  • Synthetic Aperture Radar(SAR) satellite system for broad-area imaging has RF systems including SAR radiating a high power, data link system transmitting the acquired image data from the SAR, TC&R(Telemetry, Command, and Ranging) to communicate with a ground segment to control a satellite. Each system transmits RF signal having various frequencies and radiates a high power, RS(Radiated Susceptibility) specification should be verified at an electronic unit mounted in satellite. RF interference can be happened because of non-linearity of a RF system. Therefore, we manufactured a structure model installed antennas which have a similar pattern with a real antenna, the effect by RF interference is analyzed and verified.

  • PDF

Development of the 3kW Class Low Cost Fuel Inverter System for Residential Power Generation - DC-DC Converter Design and Control for Fuel Cell System (3kW급 주택용에 사용되는 저가의 연료전지용 인버터 시스템 - 연료전지 시스템용 DC-DC 컨버터 설계 및 제어)

  • Lee, S.H.;Cho, M.C.;Hwang, G.D.;Mun, S.P.;Suh, K.Y.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1161-1162
    • /
    • 2006
  • 본 논문은 3[kW]급 연료전지와 연료전지의 저전압$[40{\sim}60[Vdc]$)을 승압(380vdc)하기 위한 풀-브리지 DC-DC 컨버터, 그리고 승압된 링크전압을 교류 상용전압(220[Vac], 60[Hz)으로 변환하기위한 단상 풀-브리지 인버터로 구성된 연료전지 발전용 전력변환시스템 중 연료전지 시스템용 DC-DC 컨버터를 제안하였다. 제안한 연료전지 시스템용 DC-DC 컨버터는 변압기 2차측에 배전류 정류회로를 삽입하여 기존의 고주파 변압기 보다 간단하면서 무게 및 부피를 줄였다. 그리고 위상 천이 PWM 제어로 출력 전압을 가변시켜 영전압 스위칭을 달성 함으로써 스위칭 손실을 줄였으며. 효율을 95%이상 달성 하였다.

  • PDF

Characteristic Estimation of Single-Stage High Frequency Resonant Inverter Link Type DC-DC Converter (단일 전력단 고주파 공진 인버터 링크형 DC-DC 컨버터의 특성평가)

  • Won, Jae-Sun;Kim, Hae-Jun;Park, Jae-Wook;Nam, Seung-Sik;Seo, Cheol-Sik;Kim, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1190-1192
    • /
    • 2003
  • This paper presents a novel single-stage high frequency resonant inverter link type DC-DC converter using zero voltage switching with high input power factor. The proposed high frequency resonant converter integrates half-bridge boost rectifier as power factor corrector (PFC) and half-bridge resonant converter into a single stage. The input stage of the half-bridge boost rectifier is working in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that boost converter make the line current follow naturally the sinusoidal line voltage waveform. Experimental results have demonstrated the feasibility of the proposed DC-DC converter. This proposed converter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

An Analysis on Vibratory Loads Reduction using Individual Blade Control in Active Helicopter Rotors (지능형 헬리콥터 로터의 개별 블레이드 제어에 의한 진동하중 감소 해석)

  • Kim, Sung-Kyun;Shin, Sang-Joon;Kim, Tae-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.6
    • /
    • pp.496-502
    • /
    • 2007
  • In the present paper, a new version of DYMORE, which is an analysis to solve a nonlinear multi-body dynamics problem, is used to simulate an Individual Blade Control (IBC) algorithm in order to reduce vibration in helicopter rotors. The Active Twist Rotor (ATR), in which Active Fiber Composites (AFC) are embedded, is utilized for IBC. The main purpose of the present investigation is to compare the analytical results with experiments and previous version of DYMORE. The experiments are performed at NASA Langley Transonic Dynamics Tunnel. According to the present result, it is observed that the correlation regarding the vibratory loads is improved.