A Study on the Power Factor Improvement of DC Power Regenerating Systems (직류전력 회생시스템의 역률개선에 관한 연구)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • This paper proposes a new control scheme for the power factor improvement of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three-phase square-wave inverters and composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the regenerating system are not sinusoidal. However, regenerated complex power is analyzed on the basis of fundamental components and thus the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero even for nonsinusoidal cases. To verify the validity of the proposed control scheme, computer simulations are carried out. And the results show that the power factor is theoretically higher than 0.99.

  • PDF

Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine (전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석)

  • 김슬기;김응상
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.154-163
    • /
    • 2003
  • Grid connection essentially requires a wind energy conversion system (WECS) to not only supply adequate power responding to constantly varying wind speed but also provide a specified level of voltage magnitude and frequency that is acceptable in the electric power network. To satisfy such requirements, appropriate control schemes of a wind turbine to be connected to the power grid should be employed. This paper presents an output control strategy of a grid-connected wind power generation, which consists of a fixed-pitch wind turbine, a synchronous generator and a AC-DC-AC component with a voltage source inverter built in, and performs modelling and analysis of the strategy using PSCAD/EMTDC, an electromagnetic transient analysis software. Real power output control of the voltage source inverter is implemented to extract the maximum energy from wind speed inputted through wind blades and reactive power control, to keep the terminal voltage of WECS at a specific level. SPWM switching method is used to reduce the harmonics and maintain 60 ㎐ of the output frequency. The wind turbine performance and output corresponding to wind variation and the terminal load change is simulated and analysed.

Measurement and Analysis of Magnetic Field Waveform Generated by Operating Fluorescent Lamp (형광등의 사용중에 발생되는 자계파형의 측정과 해석)

  • 이복희;전덕규;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.22-29
    • /
    • 1994
  • 본 논문에서는 시변자계측정을 위한 센서와 형광등의 점등에 의하여 발생되는 자계의 특성에 대하여 기술하였다. 자계측정계는 동축케이블을 사용한 자기적분형 자계센서와 증폭기, 적분기로 구성하였으며 교정실험 결과, 주파수대역은 약 40Hz∼100kHz이었다. 수동점등식, 고주파점등식과 글로우점등식 등 여러 가지 점등방식의 형광등에 의하여 발생되는 자계의 파형을 측정하고, 측정된 자계의 주파수성분을 고속푸리에변환(fast Fourier transformation: FFT)기법으로 해석하였다. 형광등의 점등중에 발생되는 자계성분은 주로 기수고주파 성분이 많이 포함되어 있으며, 인덕션칵에 의하여 점등순간에는 급변성의 과도성분이 나타났다. 전자회로나 제어기기의 보호를 위한 자계차폐장치를 설계할 때에는 반드시 자계의 기수고조파성분을 고려하여야 됨이 확인되었다.

  • PDF

Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods (인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석)

  • 김윤호;윤병도;이병순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

Seasonal Variation of Surface Sediments in 2014 on the Gochang Open-Coast Intertidal Flat, Southwestern Korea (고창 개방형 조간대 표층 퇴적물의 2014년 계절 변화)

  • Kang, Sol-Ip;Ryang, Woo-Hun;Jin, Jae-Hwa;Chun, Seung-Soo
    • Journal of the Korean earth science society
    • /
    • v.37 no.2
    • /
    • pp.89-106
    • /
    • 2016
  • The Gochang open-coast intertidal flat is located in the southwestern coast of Korea (the eastern part of the Yellow Sea), characterized by macro-tidal range, an open-coast type, and sand substrates. This study has investigated seasonal variation in sedimentary facies of surface sediments in the Gochang intertidal flat. In the four seasons of February, May, August, and November, 2014, surface sediments of 252 sites in total were sampled and analyzed along three survey lines. The surface sediments of the Gochang intertidal flat in 2014 consisted mainly of fine-grained sand sediments showing a trend in grain size to be coarser in winter and finer in summer. Based on seasonal wave and tidal level data recorded near the study area, it was interpreted that the seasonal effects of wave were stronger than those of tide as a factor controlling surface sedimentation. High waves in winter resulted in the coarsening trend of grain size in surface sediments, whereas, during summer time, the sediments became finer by relatively low waves. Spatial sedimentary facies of the Gochang intertidal flat in 2014 represented that seasonal deviation of the upper tidal zone was larger than that of the lower tidal zone, hence sediments getting coarser in grain size and poorly sorted in the upper tidal zone. From upper to lower tidal zone, the grain size became finer and sediments were better-sorted, showing smaller seasonal deviations.

Construction Broadband CARS Spectrometer and Uncertainty Analysis of Temperature Measurement (광대역 CARS 분광기의 제작과 온도 측정의 정확도 분석)

  • 박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.226-232
    • /
    • 1993
  • A broadband CARS system is constructed for shot by shot measurement of a full CARS spectrum, which consists of a frequency doubled Nd:Yag laser, broadband mode-less laser and optical multi-channel analyzer installed in a double grating monochromator. To increase the accuracy of CARS temperature measurement and get better the fitting goodness, we have measured the slit function of the detection system and determined the analytical functional form of the slit function. Accuracy of the CARS system for temperature measurement is evaluated from the difference between the best-fit temperature of CARS spectrum and temperature of thermocouple reading. The uncertainty of the temperature measurement is found to be less than 1.5% in temperature range from 300 K to 1300 K.

  • PDF

Analysis for Thermal Distribution of Low-voltage Condenser by the Variance of Voltage & Frequency (전압 및 주파수 변화에 따른 저압 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.43-49
    • /
    • 2010
  • Power capacitor has been used to compensate for the low power factor of inductive load and to reduce harmonics generated by the power conversion device with reactor. The increase of voltage and current and thermal generation are extremely hard on the life of condenser. Current will be increased, provided that voltage and frequency of condenser increase also. The increase of voltage and frequency justly extends thermal generation. Both act on insulation stress and can afford to premature fault In this paper, we measured thermal distribution of condenser with infrared rays camera in case of variance of voltage and frequency. We were assured that the increase of voltage and frequency produces high heat and exceedingly shortens the life of condenser.

S-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 S영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Lee, J.T.;Han, H.H.;Kim, H.J.;Chong, D.I.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.143-144
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using S-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a S-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Z-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 Z영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Kim, K.Y.;Lee, J.T.;Han, H.H.;An, B.C.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.145-146
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using Z-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Design of Linearized VCDRO with Novel PBG Ground Plane and Varactor Circuit (새로운 PBG 접지면과 바랙터 회로를 이용한 선형화된 VCDRO의 설계)

  • 강성민;전종환;구경헌
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.5
    • /
    • pp.63-68
    • /
    • 2004
  • This paper presents a design of 12㎓ VCBRO(voltage controlled dielectric resonator oscillator) using a novel PBG(photonic band gap) ground plane and a varactor circuit that enhances the frequency linearity of VCO with different bias to varactors. The PBG structures are used for suppressing the second and third harmonics without any filters. To simulate the accurate resonating frequency, a DR coupled with microstrip lines is analysed by FTM(finite element method) simulation, and the results are transformed into scattering parameters to design the VCO. Some measured results are presented to show the usefulness of the proposed techniques.