• Title/Summary/Keyword: 고조파 왜곡

Search Result 170, Processing Time 0.039 seconds

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electrolyzer Loads (전해조 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Seo, Beom-Gwan;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.12-20
    • /
    • 2006
  • Heavy chemical industries have nonlinear loads including electrolyzers. The electrolysis consists of AC-BC converters which generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides in depth an analysis on harmonics field measurement for the electrolyzer loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonic assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

A Study on the Hormonic Characteristics of Typical Household Loads by Field Measurements (현장 측정에 의한 가정집 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Choi, Hyoung-Bumb
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.100-106
    • /
    • 2008
  • Typical household load have nonlinear loads including a personal computer, video, refrigerator, microwave oven, TV, and audio set. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides in depth analysis on harmonics field measurement of the typical household loads and harmonics simulation using EDSA program for the case study.

A Study on the Harmonics Evaluation of Extra High Voltage Customers by Field Tests (실측에 의한 특고압 수용가의 고조파 평가에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.50-55
    • /
    • 2007
  • A large steel industry which has nonlinear loads including electric arc furnaces is one of the extra high voltage customers. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative propablistic approach is the most commonly used method to solve time varying harmonics. In this paper the in varying harmonics of electric arc furnace loads are evaluated by international harmonic standards(IEC 61000-3-6, IEEE 519 and JIS C 61000-3-2).

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads (전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

Control of a Single-Phase PWM Converter under Distorted Source Voltage (왜곡된 전원 전압 하에서 단상 PWM 컨버터의 제어기법)

  • Ahn, Chang-Heon;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.19-20
    • /
    • 2014
  • 본 논문에서는 왜곡된 단상 전원 전압 하에서도 교류 입력 전류를 정현적으로 제어할 수 있도록 하는 제어기법을 제안하였다. 단상의 물리량을 가상의 삼상 물리량으로 변환하여 이를 d-q축 동기좌표계로 변환된 물리량으로 제어하는 동기좌표계 전류제어기법을 적용하였으며, 왜곡된 전원 전압에 의한 왜곡된 위상각 성분을 추출하여 이를 d-q축 동기좌표계 지령전류에 보상하는 방법을 제안하였다. 제안한 기법으로 왜곡된 전원 전압 하에서도 교류 입력 전류의 고조파를 5%이내로 제한할 수 있음을 시뮬레이션을 통하여 확인하였다.

  • PDF

A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the Electric Arc Furnace Loads (시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Jeon, Young-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.9-17
    • /
    • 2006
  • Large steel industries have nonlinear loads such as electric arc furnaces. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time-varying harmonics. Harmonic simulations are performed to evaluate the harmonic voltage and current distortions throughout the system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519 and harmonic simulation for the time-varying harmonics. The EDSA program was used as a simulation tool for the case study.

Analysis of the Effect of Low Pass Filter for Active Filter in Distribution System (배전계통에서의 능동 필터에 대한 LPF의 영향 분석)

  • Park, Gwang-Won;Kim, Hyoun-Su;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.221_222
    • /
    • 2009
  • 최근 전력 컨버터 사용의 증가로 배전계통에서의 고조파 왜곡이 날로 심각해지고, 따라서 고조파에 민감한 전력계통 기기와 고객 부하를 보호하기 위한 고조파 저감대책이 필요하다. 본 논문에서는 능동 필터와 Low-Pass Filter(LPF)를 전력계통 과도해석 프로그램인 Electro-Magnetic Transients Program(EMTP) 내의 Transients Analysis of Control Systems(TACS) 소자를 사용하여 모델링하고 고조파 발생시 능동필터에 LPF의 설치 유/무에 따른 배전계통에서의 상전류와 중성선 전류의 변화를 분석하였다.

  • PDF

Selective Harmonic Elimination of Three-Phase Sag Compensator for Nonlinear Load (비선형 부하에 적용 가능한 3상 새그 보상기의 선택적 고조파 보상기법)

  • Jo, HyunSik;Park, Hee-Sung;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.262-263
    • /
    • 2012
  • 3상 새그 보상기는 계통 새그나 사고 발생 시 빠르게 이상상태를 검출하여 계통을 분리하고 수퍼커패시터에 충전된 에너지를 부하에 안정하고 연속적인 정격 전압을 공급하는 장치이다. 그러나 비선형 부하일 때, 3상 새그 보상기의 출력전압에 저차 고조파가 포함된 왜곡이 발생한다. 본 논문에서는 비선형 부하에서도 안정적인 정현파 전압을 공급하기 위해 선택적 고조파 제거 방식을 도입한 전압제어기를 제안 하였다. 새그 보상기 시작품을 제작하였으며, 제안한 선택적 고조파 제거 전압제어기의 타당성을 실험을 통하여 THD가 12.7%에서 4.3%로 개선되는 것을 확인하였다.

  • PDF

A Study on the Series Resonant Filler Application and Evaluation for Personal Computer Loads (컴퓨터부하의 직렬 동조필터 적용 및 평가에 관한 연구)

  • 김경철;강윤모;이일무;송영주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.40-48
    • /
    • 2003
  • Computer loads can be found in all of modem society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as voltage waveform distortion, excessive neutral currents, errors in measurements, and disruption in computer performance. The purpose of this paper is to give an equivalent circuit modeling methodology for the harmonic currents generated by single-phase personal computer loads and to evaluate a commercially available series resonant filter for the harmonic currents compensation based on the IEEE 519-1992 and IEC1000-3-2 standards for limiting harmonic distortion.

A Study on the Harmonics Simulation of the High Speed Electric Train Loads by Field Tests (현장시험에 의한 고속전철 부하의 고조파 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.40-47
    • /
    • 2007
  • High speed electric trains have nonlinear loads including converters and inverters for the control synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. Harmonic simulations are performed to evaluate the harmonic voltage and current distortions throughout the system. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519-l992, and harmonics simulation using EDSA program for the case study.