• Title/Summary/Keyword: 고조선

Search Result 234, Processing Time 0.033 seconds

Analysis of the Effect of Low Pass Filter for Active Filter in Distribution System (배전계통에서의 능동 필터에 대한 LPF의 영향 분석)

  • Park, Gwang-Won;Kim, Hyoun-Su;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.221_222
    • /
    • 2009
  • 최근 전력 컨버터 사용의 증가로 배전계통에서의 고조파 왜곡이 날로 심각해지고, 따라서 고조파에 민감한 전력계통 기기와 고객 부하를 보호하기 위한 고조파 저감대책이 필요하다. 본 논문에서는 능동 필터와 Low-Pass Filter(LPF)를 전력계통 과도해석 프로그램인 Electro-Magnetic Transients Program(EMTP) 내의 Transients Analysis of Control Systems(TACS) 소자를 사용하여 모델링하고 고조파 발생시 능동필터에 LPF의 설치 유/무에 따른 배전계통에서의 상전류와 중성선 전류의 변화를 분석하였다.

  • PDF

Modified Wilkinson Power Divider for nth Harmonic Suppression (고조파 제거 기능을 갖는 윌킨슨 전력분배기의 설계)

  • Kim, Jong-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.46-50
    • /
    • 2013
  • A modified design that can reject the nth harmonic components in the Wilkinson power divider is presented. After adding transmission lines of electrical lengths determined by suppression terms between two transformers of the traditional design, a solution of the modified Wilkinson divider can be found. Experimental results show the second and third harmonic suppression to be -45.3 dB and -46.4 dB, respectively, while maintaining the conventional performance at the fundamental frequency.

Detection of Damage of Rd6G Film Using Surface Second-Harmonic Generation (표면 제2고조파 발생을 이용한 색소 Rd6G박막층의 손상 분석)

  • 유대혁;고춘수;임용식;이재형;장준성
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.272-277
    • /
    • 1994
  • The damage of a thin film of Rd6G dye was probed by Surface Second-Harmonic Generation(SSHG) method. A portion of the Rd6G thin film on glass substrate was damaged by 532 nm laser beam, and the damage was probed by detecting intensity variation of SSHG. The result was confirmed through direct observation with optical microscope.oscope.

  • PDF

Harmonic Frequency Analysis of Interlocking System for Rolling Stock Operation in Electrical Railroads (전기철도 구간에서의 철도차량 운행에 따른 연동장치 고조파 분석)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3610-3616
    • /
    • 2011
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. The used load current depending on the operation of rail vehicles in the electric railway sections returns to the substation through a track which is a return circuit. The load current contains harmonics because of the power conversion equipment used in rolling stocks and such harmonic currents should not affect train control system. In this paper we present the test result in order to verify that the harmonics produced by the operation of rail vehicles in the newly built electric railway sections can affect interlocking systems. The test in question was performed in a linking section that trackside equipment under railway operating conditions and interlocking are linked in order to identify whether or not the interlocking fitted in a signal machine room can be affected by harmonics according to railway operation.

Harmonic Reduction of Electric Propulsion Ship using New Rectification Scheme (새로운 정류방식을 이용한 전기추진선박의 고조파 저감)

  • Kim, Jong-Su;Choi, Jae-Hyuk;Yoon, Kyoung-Kuk;Seo, Dong-Hoan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2230-2236
    • /
    • 2012
  • Currently, the AC-to-DC power conversion system using diode rectifiers is mainly used in large vessels. Also, to reduce the total harmonic distortion(THD) of current and voltage, this system requires an additional phase-shifting transformer which can be powered multi-pulses. In this case, due to the installation of the transformer, the spatial or economic loss occurs. This paper presents a novel active rectification scheme using silicon controlled rectifier(SCR) or insulated gate bipolar transistor(IGBT) devices on behalf of the diode rectifiers which are currently operating in large vessels such as LNG Carrier(LNGC). The proposed system can use the low voltage source and reduce current and voltage harmonics generated by nonlinear loads connected to the power distribution bus and save economic costs by removing the phase-shifting transformers which are used in conventional system. Computer simulations are performed under the electric propulsion system which is operating in current large vessel. The results are shown in support of the improvement of THD included in the current and voltage wave forms of propulsion motor.

On the Studies of Koguryo Archaeology in North Korea (북한의 고구려 고고학 조사·연구의 성과와 과제)

  • Kang, Hyunsook
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.106-125
    • /
    • 2020
  • From 1949 to the present day, many Koguryo sites have been excavated, in North Korea. It can also be said that archaeological surveys and studies in North Korea have triggered Koguryo archaeological studies in South Korea. However, since the 1990s, the excavation of Koguryo sites and archaeological research in North Korea has been carried out as an extension of Daedonggang culture. Therefore, these archaeological surveys focused on the Pyongyang and more general northwestern areas of North Korea, and the conclusion was that Koguryo was a powerful nation with a millennium-long history inherited Gojoseon. Beginning in 1945 in North Korea, the archaeological surveys and related systems were organized, and burial mounds, castles, and city remains were excavated under the idea that Koguryo was a millennium-long, strong nation. In addition, archaeological research has been conducted to validate and confirm this belief. On the notion that Koguryo was founded in 277 BCE, it was insisted that the age of the tombs in Pyongyang was increased and Pyongyang took the position as a Vice Capital in the 4th Century. Recently an excavation of the castle located in Pyongyang supports the idea that Koguryo inherited Gojoseon on a layered basis. However, the archaeological and conceptual grounds for the founding of Koguryo in the 3rd Century BCE or the succession of Gojoseon and Koguryo were insufficient. As can be seen from the reconstruction of the royal tombs of the Dongmyung and Dangun, the archaeological surveys in North Korea were criticized for their selective discoveries and arbitrary interpretations. This further supports the necessity for joint excavations and academic exchanges between South and North Korea.

Performance of Multi-Code CDMA Schemes on Non-Caussian Impulse Noise in Power Line Communication Channels (전력선 통신 채널의 비 가우시안 임펄스 잡음에 대한 멀티코드 CDMA 방식의 성능)

  • 나성주;신요안
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.9-12
    • /
    • 1999
  • 전력선은 백색 가우시안 배경 잡음뿐 아니라 임펄스 잡음, 고조파 잡음 등의 비 가우시안 잡음들로 인해 통신 채널로서 열악한 전송 특성을 나타낸다. 또한 좁은 가용 대역폭으로 인해, 광대역 특성이 요구되는 DS-CDMA 방식과 같은 대역 확산 시스템의 적용에 한계가 있다. 본 연구에서는 차세대 고속이동통신을 위한 다원접속/변조방식인 멀티코드 (multi-code) CDMA 방식과 이에 길쌈 부호와 인터리빙 등의 부호화 기능을 더한 시스템을 전력선 통신 시스템에 적용하고, 모의실험을 통해 전력선 채널의 비 가우시안 잡음의 영향을 매우 효과적으로 보상할 수 있음을 확인하였다.

  • PDF

A Study on Control and Compensating Characteristics of Active Series Voltage Compensator with Harmonic Current Compensating Capability (고조파전류 보상 기능을 갖는 능동 직렬 전압보상기의 제어 및 보상특성에 관한 연구)

  • 이승요;김홍성;최규하;신우석;김홍근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.484-492
    • /
    • 2000
  • In this paper, a voltage compensator with harmonic current compensating capability is studied and its compensating characteristics are analyzed. Like the hybrid active power filter, the proposed system is composed of parallel LC passive filter and series PWM converter connected to power line through series transformer. It is shown that the compensation of harmonic current generated due to nonlinear loads such as diode rectifier and instantaneous voltage compensation of the source are performed through the proposed compensating system. The operating principle of the proposed system is described through a single-phase equivalent circuit and the control strategy is suggested on the d-q rotating reference frame of the 3-phase system. Also, experiment is carried out to verify compensating characteristics of the proposed system.

  • PDF

Development of the Harmonics Reduction and Energy Saving Equipment in Variable Loads (부하변동 시의 고조파제거 및 절전기 개발)

  • Song, Young-Bok;Cho, Yong-Hyun;Choi, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.87-95
    • /
    • 2006
  • In this study, in order to obtain high qualify of electric power, single phase active filter which is composed of Zig-Zag transformer and three phase bridge rectifier and capacitor at the secondary of its transformer to be able to reduce the components of the zero phase current and the third harmonic current in neutral line and power line respectively. By connecting this filter to the Zig-Zag transformer and nonlinear load, their third harmonic components due to the nonlinear loads were reduced.

Modeling of Grid Connected PV Generation System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 계통연계형 태양광 발전시스템 모델링)

  • Park, Jae-Gyun;Oh, Yong-Taek
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.226-228
    • /
    • 2009
  • 본 논문에서는 분산전원 시스템을 등가회로를 이용하여 수학적으로 모델링하고, 이를 결합하여 제어 가능한 시스템을 모델링하였다. 시뮬레이션과 실험 결과로부터, 선로 모의실험을 통한 고조파 해석을 IEEE Std 1547.1-2005의 고조파 연계 기준을 통하여 모델링의 적합유무를 판단할 수 있었다. 제시한 계통연계 태양광발전 시스템은 점차적으로 활성화되고 있는 태양광발전 시스템 계통연계 연구에 유용하게 활용될 것이다.

  • PDF