• Title/Summary/Keyword: 고조선

Search Result 234, Processing Time 0.018 seconds

Relationship between the Ancient Silk Road and High-technology Machine in Producing Kyung-Geum (고대 실크로드와 고조선 경금 제직기의 연관성 고찰)

  • Kim, Ji-Su;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.23 no.4
    • /
    • pp.117-142
    • /
    • 2020
  • This study aims to look for the main transport road of the ancient Silk Road and to add to the hidden history of silk, where little is known about the weaving technology of the beautiful silk of GoJoseon. The research was through the analysis of relics of empirical data and analyzed the secondary data collected from books, papers, and photos of artifacts. The research questions are as follows: First, investigates the environment of silk production for GoJoseon KyungGeum and the correlation between ancient Silk Road and the East region. Second, examines the advanced weaving technology of KyungGeum in GoJoseon. The findings of the study are as follows: It is possible to infer the production period of silk in GoJoseon through jade silkworms from the Hongsan Dong-Yi culture of 4500 BC. KyungGeum pieces were excavated in Louran, Astana and Niya of the Xinjiang Autonomous Region and Noin-Ula of Mongolia, and the oldest KyungGeum was found in JoYang, one of the capitals of GoJoseon near Balhae Bay. KyungGeum was invented in the 11th century BCE here. It became the brocade and damask of the West, which were delivered through steppe road before the 5~6th century BCE. The production of KyungGeum was possible through the advanced loom which is GoJoseon's horizontal square 'Jewharu' loom combined with a high level of weaving skill. This can't be made through the slant loom of China nor vertical loom of the West Asia. Based on these results, it is suggested to continue the research on the history of ancient silkroad.

New harmonic drop device develop take advantage of Zig-zag TR line and Open Delta mode (Zig-zag 결선 및 Open Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Yoo, Sang-Bong;Lee, Sung-Ho;Kim, Gi-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.101-104
    • /
    • 2004
  • The past harmonic filter was reactor and Zig-zag. However neutral reactor over heating become an issue. If take advantage of Zig-zag TR line and Neutral line Open Delta mode TR to disappear TR sounds and harmonic by the help of experiments. The disappear harmonic have not relation of neutral line electric current quantity

  • PDF

A Study on the Measurements, Moldeling, and Passive Filter Application of Neutral Hormonic Currents by Field Tests (현장시험에 의한 중성선 고조파 전류 측정, 모델링 및 수동필터 적용에 관한 연구)

  • 김경철;강윤모;이일무
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 2003
  • With the proliferation of nonlinear loads such as personal computer in an educational building, high neutral harmonic currents have been observed. High neutral currents in three-phase four ire distribution power systems can cause tots of harmonic problems such as overloaded neutral conductors and malfunction of protective equipment. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuits was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB. Simulation results verifying the effect of a single-tuned passive filter for the neutral harmonic current reduction are presented.

Effects of Power Line Carrier by Harmonics Source in Low-Voltage Power Distribution Network (저압 배전선의 고조파 성분이 통신신호에 미치는 영향)

  • Lee, J.J.;Lee, J.H.;Seo, J.W.;Jung, H.S.;Shin, M.C.;Park, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.205-207
    • /
    • 2000
  • 본 논문에서는 전력선을 통신 매체로 한전력선 통신시 전력선상에 항시 존재하는 전원 주파수의 고조파와 부하로 인한 고조파 부하 투입시 발생하는 임펄스형 잡음이 통신신호에 미치는 영향과 그 특징을 조사하였다. 통신 신호에 미치는 영향을 측정하기 위하여 모의 실험을 위한 별도의 전력선을 설치하였다. 또한 실제 전력선 통신을 재현하기 위하여 HTH사와 Intelogis사의 전력선 모뎀을 사용하였으며, 고조파 성분과 임펄스형 잡음의 실현을 위하여 인버터, 고조파 발생장치, 스위칭 부하를 설계하여 사용하였다.

  • PDF

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.

The Ground Impedance Influence on Neutral Harmonic Currents (접지 임피던스가 중성선 고조파 전류에 미치는 영향)

  • Kim, Kyung-Chul;Paik, Seung-Hyun;Lee, Il-Moo;Kim, Jong-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2004
  • With the proliferation of nonlinear loads such as switching mode power supplies, high neurtral harmonic currents in three-phase four-wire distribution system have been observed. It has been known that the grounded impedance has an effect on the neutral current of a system which operates with harmonics present since the neutral conductor is grounded. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuit was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB. Simulation results verifying the relationship between the neutral harmonic current and ground impedance are presented.

The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis (Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링)

  • 백승현;김경철;최종기;이일무;백남웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.181-187
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fall-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

A Study on the Problems of the Neutral Line Due to the 3rd Harmonic (중성선 공용시 3배수 고조파에 따른 문제점 분석)

  • Cho, Nam-Hun;Jung, Jum-Soo;Park, Yong-Woo;Ha, Bok-Nam;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.76-83
    • /
    • 2008
  • The neutral current is made of both the load unbalanced current and the 3rd harmonic. The 3rd harmonic which is the source of the main neutral current is generated from the loads using bridge rectifier circuits on their input produce currents. TV, computer and monitor which are belong to IEC 61000-3-2 Class D are the main 3rd harmonic current sources. In order to show the affect of the distribution system by these disturbances, this paper has studied the current standards of the Korea Electric and considers the problem of the neutral common.

A Study on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Commercial Facility Loads (상업용 설비 부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.54-60
    • /
    • 2004
  • With the proliferation of nonlinear loads such as commercial facilities in all of modern society high neutral harmonic currents have been observed. High neutral currents in three-phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to commercial office loads for eliminating harmonics. Experimental results m compared numerically and graphically with simulation results through the use of MATLAB.

A Stduy on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Lighting Loads (조명부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구)

  • Kim, Kyung-Chul;Lee, Il-Moo;Jung, Yung-Ho;Paik, Seung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.59-64
    • /
    • 2004
  • With the proliferation of nonlinear loads such as lighting facilities in all modern society high neutral harmonic currents have been observed. High neutral currents in three- phase four-wire distribution systems can cause lots of harmonic problems. The most common solution of neutral harmonic currents reduction is a zero phase sequence filter using zig-zag transformer. This paper analyzes a commercially available neutral line zero sequence currents reduction device and applies the equipment to lighting loads for eliminating harmonics. Experimental results are compared numerically and graphically with simulation results through the use of MATLAB.