• Title/Summary/Keyword: 고정축

Search Result 318, Processing Time 0.021 seconds

Massive Rotator Cuff Tear Repair (광범위 회전근 개 파열의 봉합술)

  • Shin, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.167-174
    • /
    • 2010
  • Purpose: Anatomical repair of massive rotator cuff tear has been technically challenging because of medial retraction, muscle atrophy and fatty degeneration. Among several treatment options for massive rotator cuff tear, we reviewed rotator cuff repairs and investigated modalities for improvement of clinical outcomes, decreasing the re-tear rate, and increasing healing. Materials and Methods: Patient-related factors and rotator cuff-related factors were the two major groups of factors we considered when choosing a treatment plan. Results: Mobilization of a massive rotator cuff tear was increased by soft tissue release and by the interval slide technique. After meticulous soft tissue release, anatomical repair could be achieved. If the injury was not amenable to anatomical repair, alternative treatment options such as partial repair, the margin convergence technique and augmentation with a tenotomized biceps tendon were considered. Many reports of massive rotator cuff repair demonstrated satisfactory clinical outcomes, decreased pain, recovery of shoulder functions, and increases in muscle strength. However, the re-tear rate had been reported to be relatively high in long-term follow-up. Conclusion: Despite a high re-tear rate after massive rotator cuff repair, a better understanding of the pathogenesis, progression and clinical symptoms of massive rotator cuff tear and improved surgical materials and techniques will lead to satisfactory clinical outcomes.

A Study of Vertical Axis Wind Turbine by Simulation (시뮬레이션을 통한 수직축 풍력발전에 관한 연구)

  • Park, Jung-Cheul;Won, Woo-Yeon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.3
    • /
    • pp.241-245
    • /
    • 2018
  • This paper designed the main blade in V-shape and tried to identify the best design conditions by changing the main blade angle and wind speed. When the main blade open angle was maintained at $120^{\circ}$ and the sample2 with an angle changed by $30^{\circ}$ was compared with the sample3 changed by $60^{\circ}$, the power output of sample2 was 3.8[kW], the power coefficient was 0.12, and the power output of sample3 was 6.0[kW], the power coefficient was measured as 0.18. So the power output of sample 3 was 58% higher than that of sample2, and the power coefficient was increased by 50%. The power coefficient was 0.18 and the wind speed was changed to 10[m/s] at 6.0[kW] at wind speed of 7[m/s] by fixing main blade open angle of $120^{\circ}$ and angle of $60^{\circ}$. The output was measured at 7.7[kW] and the power coefficient at 0.23. When the wind speed was high, the power output increased by 28% and the power coefficient increased by 83%. Also, sample4 was 103% higher in output and 92% more in efficiency than sample2.

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

Soft Magnetic Property Depending on thickness of Free Layer in CoFe/Cu/CoFe/IrMn Spin Valve Film (CoFe/Cu/CoFe/IrMn 스핀밸브 박막의 자유층 두께 감소에 따른 연자성 자기저항 특성 연구)

  • Choi, Jong-Gu;Go, In-Suk;Gong, Yu-Mi;Kim, Min-Ho;Park, Young-Suk;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.2
    • /
    • pp.52-56
    • /
    • 2009
  • Interlayer coupling field, coercivity, magnetoresitance ratio, and magnetic sensitivity depending on the thickness of free CoFe layer for the CoFe/Cu/CoFe/IrMn multilayer are investigated. In case of CoFe layer of $30\;{\AA}$ thickness for the CoFe(t)/Cu($25\;{\AA}$)/CoFe($60\;{\AA}$)/IrMn($80\;{\AA}$) multilayer with ferromagnet/non-magnet/ferromagnet structure induced by IrMn layer, the lowest coercivity and the highest magnetic sensitivity, which is contained soft magnetic property, are observed. On the other side, in case of CoFe layer of $90\;{\AA}$ thickness, there are the highest coercivity and the lowest magnetic sensitivity. The fabricated CoFe($30\;{\AA}$)/Cu($25\;{\AA}$)/CoFe($60\;{\AA}$)]/IrMn($80\;{\AA}$) spin valve device with $2{\times}8{\mu}m^2$ patterning size are measured by two probe method, which is selected the sensing current as the longitudinal direction and the easy axis as the transversal direction. The measuring magntoresistance ratio and magnetic sensitivity of GMR-SV device having the soft magnetic property are 3.0% and 0.3%/Oe, respectively.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

A study on the optical properties of $LiNbO_3$ single crystal grown by Floating zone method (Floating zone 법에 의한 $LiNbO_3$ 단결정의 광학적 특성에 관한 연구)

  • Ko, J.M.;Cho, H.;Kim, S.H.;Choi, J.K.;Auh, K.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.4
    • /
    • pp.318-331
    • /
    • 1995
  • The c - axis oriented single crystal of $LiNbO_3$ and $LiNbO_3$ : 5mol%MgO was success-fully grown by Floating zone method using halogen lamp as a heat source. The effects of the sintering condition of the feed rod and the atmosphere gas during the crystal growth on the be havior of the feed rod/melt interface were studied for growing crystal with the high quality, and then, the optimum growth conditions were determined by studying the experimental param eters, such as gas flow rate, pulling rate, rotation speeds of the feed rod and the seed. The grown crystals were analyzed using the chemical etching to observe the tch pattern and the ICP (Inductively Coupled Plasma) to determine the composition uniformity and the impurity content of Fe. The effects of additive (5 mol % MgO) on the transmittance and refractive index was, also, analyzed. In order to compare the nonlinear optical oharacteristics of $LiNbO_3$ with those of the other optical materials, the nonlinear optical refractive index ($n_2$) was calcu l lated using the measured refractive index.

  • PDF

Lateral Behavior of Abutment Piles in Full Integral Bridge During 7 Days in Response to Hydration Heat and Drying Shrinkage (수화열과 건조수축에 의한 7일간의 완전 일체식 교량 교대 말뚝기초의 횡방향 거동)

  • ;;;;Thomas A. Bolte
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.127-149
    • /
    • 2003
  • The bridge tested was 3 spans 90m-long PSC beam concrete bridge with a stub-type abutment which had a skew of 60$^{\circ}$ about the axis of bridge. A cement concrete was placed at the superstructural slab of the bridge. Inclinometers and straingauges were installed at piles as well. During 7 days-curing of superstructural slab, the pile behavior in response to hydration heat and drying shrinkage of the slab was monitored. Then monitored values were compared with the horizontal movement obtained from the HACOM program and the calculated lateral behavior obtained from the nonlinear p-y curves of pile. As a result, lateral behavior of H-piles by the field measurement occurred due to the influence of hydration heat and drying shrinkage obtained during curing of superstructural concrete. The lateral displacements by hydration heat and drying shrinkage were 2.2mmand 1.4mm respectively. It was observed as well that the inflection point of lateral displacement of pile was shown at 1.3m down from footing base. It means that the horizontal movement of stub abutment did not behave as the fixed head condition of a pile but behave as a similar condition. The measured bending stress did not show the same behavior as the fixed head condition of pile but showed a similar condition. The increment of maximum bending stress obtained from the nonlinear p-y curves of pile was about 300(kgf/$\textrm{km}^2$) and was 2 times larger than measured values regardless of installation places of straingauges. Meanwhile, lateral load, maximum lateral displacement, maximum bending stress and maximum bending moment of pile showed a linear behavior as curing of superstructural concrete slab.

EFFECTS ON THE ENLARGEMENT RATIOS DUE TO CHANGES OF HEAD POSTURE ON LATERAL HEADFILMS (측두 규격방사선사진 촬영시 두부의 위치변화가 확대율에 미치는 영향)

  • Seo, Young-Hun;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.185-194
    • /
    • 2001
  • This study was designed to evaluate the effects of angulation changes of head posture on the enlargement ratios of a lateral headfilm depending on the vortical or horizontal rotation of the objects. A device was constructed to measure regional changes of enlargement ratios. The device was held within the cephalostat and cephalograms recorded at each measured degrees of the device tilting, vertically and horizontally. The enlargement ratios of the horizontal, vertical, and angular measurements on the films taken at each tilted angulations were obtained and compared with those on the films taken without rotation. In summary, the enlargement ratios of the horizontal linear measurements were decreased during horizontal rotations. The enlargement ratios of vortical measurements of the right side on the film were increased and those of the left side were decreased by the horizontal rotations. Enlargement ratios of horizontal measurements were affected further than those of vertical measurements by the same angular changes of the horizontal rotations. Therefore, a disruption of parallelism between the object's midsagittal plane and the film could result in distortion of the image while vertical rotation around the object's porionic axis would not significantly affect the enlargement ratios on the headfilm.

  • PDF

Design and Array Signal Suggestion of Array Type Pulsed Eddy Current Probe for Health Monitoring of Metal Tubes (금속배관 건전성 감시를 위한 배열형 펄스와전류 탐촉자의 설계 및 배열신호 제안)

  • Shin, Young Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.291-298
    • /
    • 2015
  • An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.

Image Quality Improvement in Computed Tomography by Using Anisotropic 2-Dimensional Diffusion Based Filter (비등방성 2차원 확산 기반 필터를 이용한 전산화단층영상 품질 개선)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study was tried to remove the noise and improve the spatial resolution in the computed tomography (CT) by using anisotropic 2-dimensional (2D) diffusion based filter. We used 4-channel multi-detector CT and american association of physicists in medicine (AAPM) phantom was used for CT performance evaluation to evaluate the image quality. X-ray irradiation conditions for image acquisition was fixed at 120 kVp, 100 mAs and scanned 10 mm axis with ultra-high resolution. The improvement of anisotropic 2D diffusion filtering that we suggested firstly, increase the contrast of the image by using histogram stretching to the original image for 0.4%, and multiplying the individual pixels by 1.2 weight value, and applying the anisotropic diffusion filtering. As a result, we could distinguished five holes until 0.75 mm in the original image but, five holes until 0.40 mm in the image with improved anisotropic diffusion filter. The noise of the original image was 46.0, the noise of the image with improved anisotropic 2D diffusion filter was decreased to 33.5(27.2%). In conclusion improved anisotropic 2D diffusion filter that we proposed could remove the noise of the CT image and improve the spatial resolution.